Histopathological, cytotoxicity and genotoxicity evaluation of Biosilicate® glass–ceramic scaffolds
Source abstract
Abstract
Abstract This study evaluated the biocompatibility of Biosilicate® scaffolds by means of histopathological, cytotoxicity, and genotoxicity analysis. The histopathologic analysis of the biomaterial was performed using 65 male rats, distributed into the groups: control and Biosilicate®, evaluated at 7, 15, 30, 45, and 60 days after implantation. The cytotoxicity analysis was performed by the methyl thiazolyl tetrazolium (MTT) assay, with various concentrations of extracts from the biomaterial in culture of osteoblasts and fibroblasts after 24, 72, and 120 h. The genotoxicity analysis (comet assay) was performed in osteoblasts and fibroblasts after contact with the biomaterial during 24, 72, and 96 h. In the histopathology analysis, we observed a foreign body reaction, characterized by the presence of granulation tissue after 7 days of implantation of the biomaterial, and fibrosis connective tissue and multinucleated giant cells for longer periods. In the cytotoxicity analysis, extracts from the biomaterial did not inhibit the proliferation of osteoblasts and fibroblasts, and relatively low concentrations (12.5% and 25%) stimulated the proliferation of both cell types after 72 and 120 h. The analysis of genotoxicity showed that Biosilicate® did not induce DNA damage in both lineages tested in all periods. The results showed that the Biosilicate® scaffolds present in vivo and in vitro biocompatibility. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 101A: 667–673, 2013.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. 10.1016/S0020-1383(07)80007-610.1016/S0020-1383(07)80007-6 ↗
2. 10.1016/j.pbiomolbio.2006.07.02110.1016/j.pbiomolbio.2006.07.021 ↗
3. 10.1097/00003086-199810001-0002210.1097/00003086-199810001-00022 ↗
4. 10.1126/science.106740410.1126/science.1067404 ↗
5. 10.1002/jbm.a.3116510.1002/jbm.a.31165 ↗
6. 10.1016/S0142-9612(02)00068-610.1016/S0142-9612(02)00068-6 ↗
7. ZanottoED RavagnaniC PeitlO PanzeriH LaraEH. Process and Compositions for Preparing Particulate Bioactive or Resorbable Biosilicates for Use in the Treatment of Oral Ailments. São Carlos: Universidade Federal de São Carlos Universidade de São Paulo;2004. International Classification C03C10/00 WO 2004/074199 (INPI 03006441).
8. 10.1002/jbm.b.3179510.1002/jbm.b.31795 ↗
9. 10.1007/s10856-009-3945-410.1007/s10856-009-3945-4 ↗
10. 10.1002/term.30910.1002/term.309 ↗
11. 10.22203/eCM.v013a0110.22203/eCM.v013a01 ↗
12. Crovace MC.Obtenção de estruturas porosas altamente bioativas via sinterização do Biosilicate®. Dissertation (MSc in Materials Engineering)—Post‐Graduate Program in Science and Materials Engineering Federal University of Sao Carlos Sao Carlos;2009.120pp.
13. 10.1089/tea.2007.020510.1089/tea.2007.0205 ↗
14. 10.1007/s10856-009-3939-210.1007/s10856-009-3939-2 ↗
15. Setting properties and biocompatibility of dicalcium silicate with varying additions of tricalcium aluminate
16. 10.1016/0022-1759(83)90303-410.1016/0022-1759(83)90303-4 ↗
17. 10.1007/s10856-009-3691-710.1007/s10856-009-3691-7 ↗
18. 10.1002/(SICI)1098-2280(2000)35:3<206::AID-EM8>3.0.CO;2-J10.1002/(SICI)1098-2280(2000)35:3<206::AID-EM8>3.0.CO;2-J ↗
19. 10.1093/mutage/18.1.4510.1093/mutage/18.1.45 ↗
20. 10.1002/jor.2045310.1002/jor.20453 ↗
21. 10.1016/j.biomaterials.2005.01.07210.1016/j.biomaterials.2005.01.072 ↗
22. 10.1007/s00281-011-0244-110.1007/s00281-011-0244-1 ↗
23. 10.1002/jbm.a.3004810.1002/jbm.a.30048 ↗
24. 10.1016/j.biomaterials.2009.12.04510.1016/j.biomaterials.2009.12.045 ↗
25. 10.1016/S0142-9612(99)00249-510.1016/S0142-9612(99)00249-5 ↗
26. 10.1007/s10856-006-0025-x10.1007/s10856-006-0025-x ↗
27. 10.1006/bbrc.2000.350310.1006/bbrc.2000.3503 ↗
28. Biosilicato®: histórico de uma vitrocerâmica brasileira de elevada bioatividade
29. 10.1016/j.tiv.2009.05.02510.1016/j.tiv.2009.05.025 ↗
30. 10.1590/S1806-8324200500030000510.1590/S1806-83242005000300005 ↗
31. 10.1002/jbm.a.3183110.1002/jbm.a.31831 ↗