journal article·2007-09-15

Anodized titanium and stainless steel in contact with CFRP: An electrochemical approach considering galvanic corrosion

Yves Mueller, Roger Tognini, Joerg Mayer, Sannakaisa Virtanen

Publisher page

Abstract

Abstract The combination of different materials in an implant gives the opportunity to better fulfill the requirements that are needed to improve the healing process. However, using different materials increases the risk of galvanic coupling corrosion. In this study, coupling effects of gold‐anodized titanium, stainless steel for biomedical applications, carbon fiber reinforced polyetheretherketone (CFRP), and CFRP containing tantalum fibers are investigated electrochemically and by long‐term immersion experiments in simulated body fluid (SBF). Potentiodynamic polarization experiments (i/E curves) and electrochemical impedance spectroscopy (EIS) of the separated materials showed a passive behavior of the metallic samples. Anodized titanium showed no corrosion attacks, whereas stainless steel is highly susceptibility for localized corrosion. On the other side, an active dissolution behavior of both of the CFRPs in the given environment could be determined, leading to delaminating of the carbon fibers from the matrix. Long‐term immersion experiments were carried out using a set‐up especially developed to simulate coupling conditions of a point contact fixator system (PC‐Fix) in a biological environment. Electrochemical data were acquired in situ during the whole immersion time. The results of the immersion experiments correlate with the findings of the electrochemical investigation. Localized corrosion attacks were found on stainless steel, whereas anodized titanium showed no corrosion attacks. No significant differences between the two CFRP types could be found. Galvanic coupling corrosion in combination with crevice conditions and possible corrosion mechanisms are discussed. © 2007 Wiley Periodicals, Inc. JBiomed Mater Res, 2007
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Dental materials and restorations · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. 10.1007/978-3-662-06077-310.1007/978-3-662-06077-3 ↗
2. 10.1002/jab.77006010410.1002/jab.770060104 ↗
3. 10.1002/jbm.82028101210.1002/jbm.820281012 ↗
4. 10.1002/jbm.82024020710.1002/jbm.820240207 ↗
5. Finite element and experimental test results for peek composite intramedullary implants. Advances in Bioengineering American Society of Mechanical Engineers, Bioengineering Division (Publication)
6. 10.1023/A:100456273246010.1023/A:1004562732460 ↗
7. Characterization of carbin fiber‐reinforced peek composite for use as a bearing material in total hip replacements
8. 10.1002/jbm.82026020210.1002/jbm.820260202 ↗
9. 10.1177/00219983970310160310.1177/002199839703101603 ↗
10. 10.3109/0309190830904122110.3109/03091908309041221 ↗
11. Kovacs P · 1993 · 41
12. 10.1016/0020-1383(95)96891-710.1016/0020-1383(95)96891-7 ↗
13. 10.1007/BF0113332610.1007/BF01133326 ↗
14. 10.1016/0142-9612(90)90110-C10.1016/0142-9612(90)90110-C ↗
15. TogniniR. Das Composite‐Fliesspressen: ein neues Verfahren zur Net‐shape‐Fertigung von endlosfaserverstärkten Bauteilen mit thermoplastischer Matrix dargestellt am Beispiel einer Schraube für die translaminäre Wirbelfixation [PhD]. Zurich: ETH Zurich;2001.
16. 10.1002/jbm.82024060710.1002/jbm.820240607 ↗
17. 10.1016/0010-938X(64)90041-110.1016/0010-938X(64)90041-1 ↗