Comparison of implantation and cytotoxicity testing for initially toxic biomaterials
Source abstract
Abstract
Abstract To evaluate the predictive value of cytotoxicity testing, the present study compares the in vivo tissue responses to in vitro cytotoxicity before and after implantation. Material toxicity was caused by addition of the toxic substance Zincdiethyldithiocarbamate (ZDEC) that is used as a standard for in vitro cytotoxicity testing. Polyurethane discs with the addition of 0.5% or 1% ZDEC as well as nontoxic discs were inserted in the abdominal wall of rats for 1 day up to 6 weeks. After explantation the foreign body response was analyzed immunohistochemically. An in vitro reanalysis of the explanted reference materials (RMs) revealed remaining high concentrations of toxic compounds after 1‐week implantation, whereas no toxicity was seen after 6 weeks implantation. This was reflected in the foreign body response where a significantly thicker capsule and more inflammatory cells were seen at 1 week for the toxic implants. Over time, with decreasing toxicity, these differences disappeared. Test samples that only were subjected to in vitro extraction with water did not elute toxic compounds to the same extent as the in vivo conditions. It is concluded that many clinically useful implant materials may be unnecessarily rejected due to the results of in vitro tests. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. 10.1016/0022-3913(83)90359-110.1016/0022-3913(83)90359-1 ↗
2. 10.1126/science.362925810.1126/science.3629258 ↗
3. 10.1007/BF0236329010.1007/BF02363290 ↗
4. Brånemark P‐I · 1995 · 165
5. Surface science aspects on inorganic biomaterials
6. 10.1002/1097-4636(200011)52:2<338::AID-JBM13>3.0.CO;2-L10.1002/1097-4636(200011)52:2<338::AID-JBM13>3.0.CO;2-L ↗
7. 10.3109/1745367940899371110.3109/17453679408993711 ↗
8. 10.3109/1745367930899367910.3109/17453679308993679 ↗
9. 10.1016/S0142-9612(97)00041-010.1016/S0142-9612(97)00041-0 ↗
10. 10.1016/0267-6605(94)90081-710.1016/0267-6605(94)90081-7 ↗
11. 10.1016/S0109-5641(96)80020-010.1016/S0109-5641(96)80020-0 ↗
12. 10.1016/S0109-5641(00)00010-510.1016/S0109-5641(00)00010-5 ↗
13. 10.1016/S0142-9612(99)00223-910.1016/S0142-9612(99)00223-9 ↗
14. 10.1163/156856292X0045710.1163/156856292X00457 ↗
15. 10.1002/(SICI)1097-4636(199907)46:1<22::AID-JBM3>3.0.CO;2-R10.1002/(SICI)1097-4636(199907)46:1<22::AID-JBM3>3.0.CO;2-R ↗
16. 10.3109/0284431860900631610.3109/02844318609006316 ↗
17. 10.1016/S0142-9612(97)00012-410.1016/S0142-9612(97)00012-4 ↗
18. Siegel S · 1988 · 213
19. Biologic evaluation of filling materials. A comparison of results using cell culture techniques, implantation tests and pulp studies
20. 10.1177/08853282940090020410.1177/088532829400900204 ↗
21. 10.1002/jbm.82017010310.1002/jbm.820170103 ↗
22. 10.1016/S0883-5403(86)80004-310.1016/S0883-5403(86)80004-3 ↗
23. 10.1016/0142-9612(95)93853-610.1016/0142-9612(95)93853-6 ↗
24. 10.3171/jns.1990.73.6.093610.3171/jns.1990.73.6.0936 ↗
25. 10.1016/S0022-3913(99)70112-510.1016/S0022-3913(99)70112-5 ↗