journal article·2007-06

The effect of enzymatically degradable IPN coatings on peri‐implant bone formation and implant fixation

James E. Ho, Thomas A. Barber, Amarjit S. Virdi, Dale R. Sumner, Kevin E. Healy

Publisher page

Abstract

Abstract Short‐term osseointegration of orthopedic implants is critical for the long‐term stability of the implant–bone interface. To improve initial implant stability, one strategy under consideration involves the presentation of adhesion ligands on the implant surface to stimulate bone regeneration in the peri‐implant region. To assess the relative effects of implant surface chemistry and topography on osseointegration within the rat femoral ablation implant model, a nonfouling, enzymatically degradable interpenetrating polymer network (edIPN) of poly(AAm‐co‐EG/AAc) amenable to presenting the cell signaling domain Arg‐Gly‐Asp (RGD), was developed. Moderate enhancement of peri‐implant bone formation was found after 28 days using the edIPN without peptide modification (p = 0.032). However, no data supported a benefit of peptide modification, as bone–implant contact, normalized bone volume and normalized fixation strength was equivalent or poorer than dual acid‐etched (DAE) treated implants after 28 days. Surface topography was determined to be the dominant factor in modulating osseointegration, as DAE implants produced equivalent roughness‐normalized fixation strength versus previously reported data on plasma‐sprayed hydroxyapatite/tricalcium phosphate‐coated implants (Barber et al., J Biomed Mater Res A, forthcoming). An ideal osseointegrated implant will require optimization of all three aforementioned parameters, and may take the form of biomolecule delivery from thin degradable polymer networks. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2007
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Polymer Surface Interaction Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. 10.1016/S0022-3913(83)80101-210.1016/S0022-3913(83)80101-2 ↗
2. 10.2106/00004623-200301000-0000510.2106/00004623-200301000-00005 ↗
3. 10.1002/jbm.82026080310.1002/jbm.820260803 ↗
4. 10.1302/0301-620X.77B4.761559510.1302/0301-620X.77B4.7615595 ↗
5. 10.1002/(SICI)1097-4636(199608)31:4<465::AID-JBM5>3.0.CO;2-J10.1002/(SICI)1097-4636(199608)31:4<465::AID-JBM5>3.0.CO;2-J ↗
6. 10.1002/jbm.82029121310.1002/jbm.820291213 ↗
7. 10.1097/00003086-200212000-0000410.1097/00003086-200212000-00004 ↗
8. 10.1002/jbm.a.1050810.1002/jbm.a.10508 ↗
9. Peri‐implant bone formation and implant integration strength of peptide‐modified p(AAm‐co‐EG/AAc) IPN coated titanium implants
10. 10.1002/jbm.a.3006210.1002/jbm.a.30062 ↗
11. 10.1002/jor.2016510.1002/jor.20165 ↗
12. 10.1002/(SICI)1097-4636(199710)37:1<9::AID-JBM2>3.0.CO;2-W10.1002/(SICI)1097-4636(199710)37:1<9::AID-JBM2>3.0.CO;2-W ↗
13. 10.1021/bp980083b10.1021/bp980083b ↗
14. 10.1002/1097-4636(20001215)52:4<595::AID-JBM3>3.0.CO;2-310.1002/1097-4636(20001215)52:4<595::AID-JBM3>3.0.CO;2-3 ↗
15. 10.1034/j.1600-0501.1997.080503.x10.1034/j.1600-0501.1997.080503.x ↗
16. 10.1016/S0736-0266(03)00127-X10.1016/S0736-0266(03)00127-X ↗
17. 10.1902/jop.1999.70.2.13910.1902/jop.1999.70.2.139 ↗
18. 10.1002/jbm.a.3048210.1002/jbm.a.30482 ↗
19. 10.1126/science.282161910.1126/science.2821619 ↗
20. 10.1161/01.RES.86.8.88510.1161/01.RES.86.8.885 ↗
21. 10.1682/JRRD.2003.07.010710.1682/JRRD.2003.07.0107 ↗
22. BeatyKD.Implant surface preparation utilizing acid treatment. US Patent 5 603 338;1997.
23. BeatyKD.Implant surface preparation. US Patent 5 876 453;1999.
24. 10.1021/bm034046710.1021/bm0340467 ↗
25. 10.1163/156856298X0006410.1163/156856298X00064 ↗
26. 10.1007/s00223-004-0267-x10.1007/s00223-004-0267-x ↗
27. 10.1002/jbm.b.3029310.1002/jbm.b.30293 ↗
28. 10.1016/j.bone.2005.03.01110.1016/j.bone.2005.03.011 ↗
29. 10.1002/jbm.a.3030110.1002/jbm.a.30301 ↗
30. 10.1016/S0142-9612(99)00161-110.1016/S0142-9612(99)00161-1 ↗
31. 10.1034/j.1600-0501.2002.130312.x10.1034/j.1600-0501.2002.130312.x ↗
32. 10.1016/j.biomaterials.2004.09.03910.1016/j.biomaterials.2004.09.039 ↗
33. 10.1002/jbmr.565008031510.1002/jbmr.5650080315 ↗
34. 10.1067/mpr.2001.11241510.1067/mpr.2001.112415 ↗
35. 10.1615/JLongTermEffMedImplants.v14.i6.2010.1615/JLongTermEffMedImplants.v14.i6.20 ↗
36. 10.1002/(SICI)1097-4636(199911)47:2<139::AID-JBM4>3.0.CO;2-210.1002/(SICI)1097-4636(199911)47:2<139::AID-JBM4>3.0.CO;2-2 ↗
37. 10.1034/j.1600-0501.2001.120513.x10.1034/j.1600-0501.2001.120513.x ↗
38. 10.1097/00024720-200204000-0001510.1097/00024720-200204000-00015 ↗
39. Rate of pull‐out strength gain of dual‐etched titanium implants: A comparative study in rabbits