journal article·2005-03Open access

Antibody response to collagen after functional implantation of different polyester vascular prostheses in pigs

M. Schlosser, R. Zippel, A. Hoene, G. Urban, T. Ueberrueck, F. Marusch, A. Koch, L. Meyer, L. Wilhelm

Abstract

Abstract Besides inflammation, specific immune responses are seen also after implantation of biomaterials. The aim was to investigate the humoral response to bovine collagen type I following implantation of various polyester (Dacron) prostheses into pigs. In 24 randomized pigs, the infrarenal aorta was replaced with a segment of collagen‐impregnated, woven polyester prosthesis of low, medium, or high porosity. IgG antibodies were detected by immunoassay using native and denatured collagen type I as a target for blood samples taken on day 1 (implantation), 10, 17, 24, 62, and 116. As generally observed, antibodies to native and denatured collagen are of low titer and were significantly correlated with enhanced binding to the denatured form (p < 0.001). The highest overall antibody prevalence to native and denatured collagen was obtained on day 116 with 68% and on day 62 with 59%, respectively. Prostheses with high porosity induced an early immune response on day 10; those with low and medium porosity induced the highest antibody levels later after 2 months. Collagen antibodies neither correlated with serum IgG contents nor with antibodies to the prosthesis polyester matrix. Thus, humoral immune response against implant components may provide a further parameter in describing biocompatibility but also a potential marker that may facilitate monitoring of individual perigraft reaction. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res 72A: 317–325, 2005
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Polymer Surface Interaction Studies · Infectious Aortic and Vascular Conditions · Electrospun Nanofibers in Biomedical Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. Gelatin sealing to prevent blood loss from knitted arterial grafts
2. Arterial prosthesis of collagen‐impregnated dacron tulle
3. Experimental evaluation of a new albumin‐impregnated knitted Dacron prosthesis
4. Healing of polytetrafluoroethylene arterial grafts is influenced by graft porosity10.1016/0741-5214(90)90082-L ↗
5. The local tissue response to biomaterials
6. Clinical experience with a gelatin impregnated Dacron prosthesis in the surgical treatment of thoracic aortic aneurysm
7. 10.1583/1074-6218(1997)004<0354:AIRAWE>2.0.CO;210.1583/1074-6218(1997)004<0354:AIRAWE>2.0.CO;2 ↗
8. Postoperative inflammatory reactions to sealed Dacron prostheses: a comparison of Gelseal and Hemashield
9. 10.1067/msy.2003.17910.1067/msy.2003.179 ↗
10. 10.1177/15385744960300061410.1177/153857449603000614 ↗
11. 10.1002/jbm.82020011010.1002/jbm.820200110 ↗
12. 10.1016/S0190-9622(89)70330-310.1016/S0190-9622(89)70330-3 ↗
13. 10.1016/S0950-821X(05)80871-010.1016/S0950-821X(05)80871-0 ↗
14. 10.1067/mva.1990.2445710.1067/mva.1990.24457 ↗
15. 10.1053/ejvs.2000.129810.1053/ejvs.2000.1298 ↗
16. 10.1002/jbm.1009610.1002/jbm.10096 ↗
17. 10.1016/0003-2697(80)90300-010.1016/0003-2697(80)90300-0 ↗
18. 10.1093/humrep/deg42010.1093/humrep/deg420 ↗
19. 10.1080/0197152970800582310.1080/01971529708005823 ↗
20. 10.1016/0142-9612(94)90043-410.1016/0142-9612(94)90043-4 ↗
21. Application of collagen. Part II
22. 10.1016/0142-9612(90)90151-F10.1016/0142-9612(90)90151-F ↗
23. 10.1016/S0022-5347(01)66111-110.1016/S0022-5347(01)66111-1 ↗
24. 10.1016/S0890-5096(06)60842-X10.1016/S0890-5096(06)60842-X ↗
25. Radioimmunoassay of type I collagen that mainly detects degradation products in serum: application to patients with liver diseases10.1093/clinchem/36.3.421 ↗
26. 10.1100/tsw.2003.1310.1100/tsw.2003.13 ↗
27. Effect of collagen crosslinking on the rate of resorption of implanted collagen tubing in rabbits
28. 10.1016/S0003-4975(10)62075-910.1016/S0003-4975(10)62075-9 ↗
29. Disadvantage of “Gelseal graft” as a vascular prosthesis
30. 10.1002/jbm.82024060510.1002/jbm.820240605 ↗
31. 10.1006/jaut.1993.103110.1006/jaut.1993.1031 ↗
32. Biological safety testing of polymers
33. Objectivity in the evaluation of biological safety of medical devices and biomaterials
34. 10.1002/(SICI)1097-4636(20000315)49:4<489::AID-JBM7>3.0.CO;2-210.1002/(SICI)1097-4636(20000315)49:4<489::AID-JBM7>3.0.CO;2-2 ↗