Effect of specimen geometry on tensile strength of cortical bone
Source abstract
Abstract
Abstract We investigate the effect of specimen geometry on the ultimate tensile strength of cortical bone measured by a tensile test. This article is motivated by the fact that there is no clear consensus in the literature on a suitable specimen shape for cortical bone testing. We consider three commonly used tensile test specimen shapes: strip, dumbbell with sharp junctions, and dumbbell with rounded junctions. We conduct this study computationally, using a finite element method, and experimentally by testing porcine femurs. Our results show that local stress concentration factors in the specimen lead to reduced values in the measured tensile strength. The higher the stress concentrations are, the lower is the measured strength. We find that the strip specimens are not a good choice due to high stress concentrations. For the same reason, dumbbell specimens with sharp junctions between the grip and gage sections should also be avoided. The dumbbell shaped tensile test specimens with an arc transition and a maximized radius of fillet are a better choice because such geometry lowers stress concentrations. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2010.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone health and osteoporosis research · Hip disorders and treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (29)
Show source-provided references
1. Guo EX · 2001 · 7
2. 10.1152/jappl.1964.19.6.123410.1152/jappl.1964.19.6.1234 ↗
3. 10.2106/00004623-199308000-0000910.2106/00004623-199308000-00009 ↗
4. Regional differences in some of the physical properties of the human femur10.1152/jappl.1951.3.9.563 ↗
5. 10.1016/0021-9290(74)90018-910.1016/0021-9290(74)90018-9 ↗
6. 10.1016/S0021-9290(03)00169-610.1016/S0021-9290(03)00169-6 ↗
7. 10.1115/1.163158610.1115/1.1631586 ↗
8. 10.1006/jtbi.2002.312010.1006/jtbi.2002.3120 ↗
9. 10.1016/0021-9290(96)84546-510.1016/0021-9290(96)84546-5 ↗
10. 10.2106/00004623-197658010-0001510.2106/00004623-197658010-00015 ↗
11. 10.1002/jbm.a.3079610.1002/jbm.a.30796 ↗
12. 10.1016/j.jbiomech.2005.06.00710.1016/j.jbiomech.2005.06.007 ↗
13. 10.1016/0021-9290(90)90030-710.1016/0021-9290(90)90030-7 ↗
14. 10.1016/0021-9290(85)90205-210.1016/0021-9290(85)90205-2 ↗
15. 10.1016/0021-9290(85)90045-410.1016/0021-9290(85)90045-4 ↗
16. 10.1016/0021-9290(73)90035-310.1016/0021-9290(73)90035-3 ↗
17. 10.1016/j.jbiomech.2003.08.00810.1016/j.jbiomech.2003.08.008 ↗
18. Varying the mechanical properties of bone tissue by changing the amount of its structurally effective bone mineral content
19. 10.1007/BF0012169410.1007/BF00121694 ↗
20. 10.1016/0021-9290(95)00006-410.1016/0021-9290(95)00006-4 ↗
21. ASTM · 2006
22. 10.1115/1.218703910.1115/1.2187039 ↗
23. Bedford A · 2000 · 520
24. 10.1112/plms/s1-31.1.10010.1112/plms/s1-31.1.100 ↗
25. 10.1016/j.mechmat.2009.01.00110.1016/j.mechmat.2009.01.001 ↗
26. 10.1115/1.312281310.1115/1.3122813 ↗
27. 10.1088/0965-0393/2/3A/01710.1088/0965-0393/2/3A/017 ↗
28. 10.1098/rspa.1992.012310.1098/rspa.1992.0123 ↗
29. 10.1098/rspa.1990.001610.1098/rspa.1990.0016 ↗