journal article·2018-11

Fabrication of a bilayer scaffold for small diameter vascular applications

Allison Goins, Vidhya Ramaswamy, Darcy Lichlyter, Antonio Webb, Josephine B. Allen

Publisher page

Abstract

Abstract One of the greatest challenges plaguing cardiovascular tissue engineering has been the development of a compliant vascular graft. In this work, we report the development of a synthetic vascular graft with compliance similar to native arteries at physiological pressures. A bilayer scaffold was fabricated from a solid polymeric lumen made from poly(1,8 octanediol‐co‐citrate) (POC) and a microfibrous medial layer composed of type I collagen, elastin, and POC. Mechanical analysis revealed dynamic compliance, ~6.9% within 1% of native vessels, 5.9%. The burst pressure was an order of magnitude lower than native vessels (~400 mmHg vs. ~3000 mmHg) but was above physiological pressure ranges. Biocompatibility studies indicated the scaffold posed no acute cytotoxic risk to relevant cell types and supported the proliferation of vascular smooth muscle cells. In addition, upon exposure of the scaffold to whole blood, there was no statistically significant hemolysis, <2%. Overall this is a promising material system and scaffold to develop a biodegradable tissue‐engineered vascular graft. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 2850–2862, 2018.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Tissue Engineering and Regenerative Medicine · Aortic Disease and Treatment Approaches

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

University of Florida, Department of Materials Science and Engineering Gainesville, FL United States

University of Florida, Institute for Cell and Tissue Science and Engineering Gainesville, FL United States

Mayo Clinic Division of Cardiovascular Disease, Department of Cardiovascular Research Rochester, Minnesota United States

References (46)

Show source-provided references
1. 10.1007/s00268-006-0731-z10.1007/s00268-006-0731-z ↗
2. 10.1053/ejvs.2002.165410.1053/ejvs.2002.1654 ↗
3. 10.1039/C6TB00024J10.1039/C6TB00024J ↗
4. 10.1016/j.jmbbm.2016.01.02510.1016/j.jmbbm.2016.01.025 ↗
5. 10.1038/nrcardio.2013.7710.1038/nrcardio.2013.77 ↗
6. 10.2741/131310.2741/1313 ↗
7. 10.1046/j.1525-1594.2000.06537.x10.1046/j.1525-1594.2000.06537.x ↗
8. 10.1155/2014/92303010.1155/2014/923030 ↗
9. 10.1152/physrev.00041.200810.1152/physrev.00041.2008 ↗
10. 10.1016/j.actbio.2009.12.02910.1016/j.actbio.2009.12.029 ↗
11. 10.1016/j.jtcvs.2008.02.05810.1016/j.jtcvs.2008.02.058 ↗
12. 10.1177/088532821347789310.1177/0885328213477893 ↗
13. Natural products for antithrombosis
14. Mechanical, permeability, and degradation properties of 3D designed poly(1,8 Octanediol‐co‐Citrate) scaffolds for soft tissue engineering10.1002/jbm.b.31568 ↗
15. Hemocompatibility evaluation of poly(diol citrate) in vitro for vascular tissue engineering
16. Citric acid‐based elastomers provide a biocompatible interface for vascular grafts10.1002/jbm.a.32537 ↗
17. 10.1016/j.actbio.2006.12.00610.1016/j.actbio.2006.12.006 ↗
18. 10.1002/adma.20030626410.1002/adma.200306264 ↗
19. 10.1002/bip.2203510.1002/bip.22035 ↗
20. Design and preparation of polyurethane‐collagen/ heparin‐conjugated polycaprolactone double‐layer bionic small‐diameter vascular graft and its preliminary animal tests10.3760/cma.j.issn.0366-6999.20130029 ↗
21. 10.1016/j.actbio.2011.11.01510.1016/j.actbio.2011.11.015 ↗
22. 10.1016/j.actbio.2009.06.02610.1016/j.actbio.2009.06.026 ↗
23. 10.1089/ten.2005.11.187610.1089/ten.2005.11.1876 ↗
24. A compliant and biomimetic three‐layered vascular graft for small blood vessels
25. 10.1016/j.jmbbm.2016.01.02510.1016/j.jmbbm.2016.01.025 ↗
26. 10.1016/j.actbio.2015.01.03010.1016/j.actbio.2015.01.030 ↗
27. 10.1039/C7TB00465F10.1039/C7TB00465F ↗
28. 10.1016/j.biomaterials.2013.06.00610.1016/j.biomaterials.2013.06.006 ↗
29. Vascular wall extracellular matrix proteins and vascular diseases
30. International Standards Organization
31. International Standards Organization. (2016). Cardiovascular implants‐tubular vascular prostheses—Requirements with guidance for use (ISO Standard No. 7198).
32. 10.1016/j.biomaterials.2008.11.01110.1016/j.biomaterials.2008.11.011 ↗
33. Kim SH Hassan K Kim SH Park I Lee SH Kim SHet al. Small diameter double layer tubular scaffolds using highly elastic PLCL copolymer for vascular tissue engineering. Macromol Res2011;19: 122–129.10.1007/s13233-011-0208-2 ↗
34. 10.1016/j.actbio.2013.08.02210.1016/j.actbio.2013.08.022 ↗
35. 10.1371/journal.pone.015855510.1371/journal.pone.0158555 ↗
36. 10.1126/science.284.5413.48910.1126/science.284.5413.489 ↗
37. 10.1007/s10439-006-9226-110.1007/s10439-006-9226-1 ↗
38. 10.1016/j.biomaterials.2003.08.04210.1016/j.biomaterials.2003.08.042 ↗
39. 10.1016/j.biomaterials.2005.05.08410.1016/j.biomaterials.2005.05.084 ↗
40. 10.1002/jbm.a.3130410.1002/jbm.a.31304 ↗
41. 10.1002/jbm.a.3301010.1002/jbm.a.33010 ↗
42. 10.1016/j.biomaterials.2007.03.01310.1016/j.biomaterials.2007.03.013 ↗
43. 10.1106/NA5T-J57A-JTDD-FD0410.1106/NA5T-J57A-JTDD-FD04 ↗
44. Veith FJ Gupta SK Ascer E White‐Flores S Samson RH Scher LA et al. Six‐year prospective multicenter randomized comparison of autologous saphenous vein and expanded polytetrafluoroethylene grafts in infrainguinal arterial reconstructions. J Vasc Surg 1986;3: 104–11410.1067/mva.1986.avs0030104 ↗
45. 10.1161/01.HYP.0000107251.49515.c210.1161/01.HYP.0000107251.49515.c2 ↗
46. Venugopal J Ma LL Yong T Ramakrishna S. In vitro study of smooth muscle cells on polycaprolactone and collagen nanofibrous matrices. Cell Biol Int2005;29:861–867.10.1016/j.cellbi.2005.03.026 ↗