journal article·2015-08Open access

Poly(ethylene glycol)‐or silicone‐modified hyaluronan for contact lens wetting agent applications

Stefan M. Paterson, Lina Liu, Michael A. Brook, Heather Sheardown

Abstract

Abstract Hyaluronan (HA) is a hydrophilic biopolymer that has been explored as a wetting agent in contact lens applications. In this study, HA was modified with siloxy or polyethylene glycol moieties using click chemistry to make it more soluble in monomer solutions used to synthesize model contact lens materials; unmodified HA was not soluble in the same monomer solutions. The water contents of the silicone hydrogels were not increased by the presence of modified HA, nor was there a decrease in the surface contact angle. However, modified HA did lead to a reduction in lysozyme adsorption in some cases. The leaching rate of HA modified with polyethylene glycol from a 78:22 DMA:TRIS(OH) hydrogel was significantly slower than for unmodified HA. © 2014 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 103A: 2602–2610, 2015.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ocular Surface and Contact Lens · Advanced Drug Delivery Systems · Corneal Surgery and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Chemical Engineering McMaster University Hamilton Ontario Canada

Department of Chemistry McMaster University Hamilton Ontario Canada

School of Biomedical Engineering McMaster University Hamilton Ontario Canada

Funding

20/20 NSERC Ophthalmic Materials Network

References (30)

Show source-provided references
1. BarrJT. Contact Lens Spectrum's annual report of major corporate and product developments and events in the contact lens industry in 2004 as well as predictions for 2005.
2. 10.1097/00006324-200001000-0001210.1097/00006324-200001000-00012 ↗
3. 10.1016/j.clae.2006.12.00710.1016/j.clae.2006.12.007 ↗
4. 10.1023/A:101799170984610.1023/A:1017991709846 ↗
5. 10.1001/archopht.1994.0109014006202410.1001/archopht.1994.01090140062024 ↗
6. 10.5694/j.1326-5377.1974.tb50817.x10.5694/j.1326-5377.1974.tb50817.x ↗
7. AngJH EfronN.Corneal hypoxia and hypercapnia during contact lens wear.Optom Vis Sci1009;67:512–521.10.1097/00006324-199007000-00009 ↗
8. Soft contact lenses and long term corneal hypoxia: What is changing with silicone hydrogel lens?
9. Benifitis of silicone hydrogel lenses
10. 10.1007/s00417-005-0028-110.1007/s00417-005-0028-1 ↗
11. 10.1097/01.ico.0000243960.14651.9510.1097/01.ico.0000243960.14651.95 ↗
12. 10.1016/S0378-5173(03)00259-X10.1016/S0378-5173(03)00259-X ↗
13. 10.1016/S0168-3659(02)00207-910.1016/S0168-3659(02)00207-9 ↗
14. 10.1136/bjo.86.2.18110.1136/bjo.86.2.181 ↗
15. 10.1016/S0886-3350(00)00568-X10.1016/S0886-3350(00)00568-X ↗
16. 10.1136/bjo.81.7.53310.1136/bjo.81.7.533 ↗
17. 10.1016/0378-5173(92)90274-610.1016/0378-5173(92)90274-6 ↗
18. 10.1006/exer.1997.030210.1006/exer.1997.0302 ↗
19. 10.1002/jbm.a.3326910.1002/jbm.a.33269 ↗
20. 10.1177/088532821244693610.1177/0885328212446936 ↗
21. 10.3390/ma504068410.3390/ma5040684 ↗
22. 10.1016/j.polymer.2005.03.02210.1016/j.polymer.2005.03.022 ↗
23. 10.1038/nmat247310.1038/nmat2473 ↗
24. 10.1016/j.biomaterials.2007.10.03910.1016/j.biomaterials.2007.10.039 ↗
25. 10.1016/j.carbpol.2011.01.02110.1016/j.carbpol.2011.01.021 ↗
26. 10.1016/j.actbio.2010.12.00510.1016/j.actbio.2010.12.005 ↗
27. 10.1021/bm070080010.1021/bm0700800 ↗
28. 10.1021/bm300796q10.1021/bm300796q ↗
29. Contact interactions with the tear film
30. 10.1136/bjo.70.4.24610.1136/bjo.70.4.246 ↗