End of Life Biocompatibility Assessment for Chronically Implanted Cardiac Leads
Source abstract
Abstract
ABSTRACT Medical devices should be biocompatible throughout the entire lifecycle, but the evaluation for biocompatibility is typically performed on a new, fully finished device. While long‐term implantable devices such as cardiac leads maintain function for more than a decade, studies have not addressed changes in extractable species throughout the implant life cycle. In this study, we performed extractables analysis on cardiac leads that were implanted in humans for times ranging from 3 to 130 months. The exhaustive extracts were analyzed using liquid chromatography coupled to mass spectrometry to identify and relatively quantify extractable species. Over implant times exceeding a decade, no new species were formed, and the quantity of each class of mobile species remained constant or decreased over time. Polyurethane oligomers, a byproduct of the polymerization route, generally remained at constant levels, suggesting that there is little to no driving force for them to enter the surrounding tissue. Small molecule additives, such as the antioxidant Irganox 1076, contained within the polyurethane outer coating, decreased at a rate that was consistent with diffusional release rather than reactive consumption. These results support two important conclusions. First, the chemical profile of the mobile species does not change over the implanted lifecycle, indicating the biocompatibility of durable cardiac leads does not change over time. Second, the toxicological assumption that all mobile species identified in exhaustive extractions of a new device are released upon implant is extremely conservative when contrasted with the diffusional release rates measured in the human explanted leads studied herein.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Electrospun Nanofibers in Biomedical Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Global Technology and Innovation Medtronic Inc Minneapolis Minnesota USA
Center for Devices and Radiological Health FDA Silver Spring Maryland USA
Characterization Facility University of Minnesota Minneapolis Minnesota USA
References (25)
Show source-provided references
1. International Organization for Standardization (ISO) “Biological Evaluation of Medical Devices—Part 18: Chemical Characterization of Medical Device Materials Within a Risk Management Process (ISO 10993‐18:2020) ”2020.
2. International Organization for Standardization (ISO) “Biological Evaluation of Medical Devices—Part 5: Tests for In Vitro Cytotoxicity (ISO 10993‐5:2009) ”2009.
3. International Organization for Standardization (ISO) “Biological Evaluation of Medical Devices—Part 23: Tests for Irritation (ISO 10993‐23:2021) ”2021.
4. International Organization for Standardization (ISO) “Biological Evaluation of Medical Devices—Part 10: Tests for Skin Sensitization (ISO 10993‐10:2021) ”2021.
5. International Organization for Standardization (ISO) “Biological Evaluation of Medical Devices—Part 11: Tests for Systemic Toxicity (ISO 10993‐11:2017) ”2017.
6. 10.1002/pol.2023021910.1002/pol.20230219 ↗
7. “Regulation (EU) 2017/745 of the European Parliament and of the Council of 5 April 2017 on Medical Devices Amending Directive 2001/83/EC Regulation (EC) No 178/2002 and Regulation (EC) No 1223/2009 and Repealing Council Directives 90/385/EEC and 93/42/EEC Current Consolidated Version: 09/07/2024 ELI ”http://data.europa.eu/eli/reg/2017/745/oj.
8. 10.1021/acsmacrolett.0c0068510.1021/acsmacrolett.0c00685 ↗
9. 10.1016/j.hrthm.2018.10.02410.1016/j.hrthm.2018.10.024 ↗
10. 10.1016/j.hrthm.2024.02.06210.1016/j.hrthm.2024.02.062 ↗
11. “Medtronic.com ” accessed December 14 2024 https://www.medtronic.com/us‐en/healthcare‐professionals/products/cardiac‐rhythm/icd‐systems/sprint‐quattro.html.
12. International Organization for Standardization (ISO) “Biological Evaluation of Medical Devices—Part 12: Sample Preparation and Reference Materials (ISO 10993‐12:2021) ”2021.
13. Robinson D. N. · 2008
14. 10.1017/CBO978051180513410.1017/CBO9780511805134 ↗
15. 10.1155/2020/886957610.1155/2020/8869576 ↗
16. 10.5603/CJ.2013.010310.5603/CJ.2013.0103 ↗
17. PubChem “National Library of Medicine National Center for Biotechnology Information ”https://www.pubchem.ncbi.nlm.nih.gov.
18. Advanced Chemistry Development “ChemSketch ” 2022 Version 2022.2.3. File Version C45H41 Build 130928.
19. 10.1016/j.ijheatmasstransfer.2006.11.00310.1016/j.ijheatmasstransfer.2006.11.003 ↗
20. 10.1002/jbm.b.3556710.1002/jbm.b.35567 ↗
21. 10.1016/j.polymdegradstab.2017.07.02110.1016/j.polymdegradstab.2017.07.021 ↗
22. 10.1002/jbm.a.3583710.1002/jbm.a.35837 ↗
23. 10.1093/imammb/dqae02010.1093/imammb/dqae020 ↗
24. 10.1002/9781119818236.app510.1002/9781119818236.app5 ↗
25. 10.1016/j.smim.2007.11.00410.1016/j.smim.2007.11.004 ↗