journal article·2006-01

Adhesion enhancement of steel fibers to acrylic bone cement through a silane coupling agent

S. P. Kotha, M. Lieberman, A. Vickers, S. R. Schmid, J. J. Mason

Publisher page

Abstract

Abstract The use of a silane coupling agent (methacryloxypropyl‐trichlorosilane) to improve the mechanical properties of steel fiber‐reinforced acrylic bone cements was assessed. Changes to the tensile and fracture properties of bone cements reinforced with silane‐coated or uncoated 316L stainless steel fibers of different aspect ratios were studied. Contact‐angle measurements indicated that the coupling agent coats the metal surface through room temperature treatments in a short time (within 2 h). Push‐out tests indicated that the interfacial shear strength of silane‐coated 316L stainless steel rods is 141% higher than the uncoated rods. The elastic moduli, ultimate stresses, and fracture toughness of the silane‐coated, steel fiber‐reinforced bone cements are significantly higher than the bone cements reinforced with uncoated steel fibers. There were no differences in the tensile mechanical properties of the silane‐coated or uncoated, steel fiber‐reinforced cements after aging in a physiological saline solution, indicating that the bonding effectiveness is decreased by the intrusion of water at the metal–polymer interface. Because of possible biocompatibility issues with leaching of the silane coupling agent and no long‐term mechanical benefit in simulated aging experiments, the use of these agents is not recommended for in vivo use. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. 10.1002/(SICI)1097-4636(199722)38:2<155::AID-JBM10>3.0.CO;2-C10.1002/(SICI)1097-4636(199722)38:2<155::AID-JBM10>3.0.CO;2-C ↗
2. 10.1002/(SICI)1521-4052(199912)30:12<746::AID-MAWE746>3.0.CO;2-310.1002/(SICI)1521-4052(199912)30:12<746::AID-MAWE746>3.0.CO;2-3 ↗
3. 10.1016/S0021-9290(01)00216-010.1016/S0021-9290(01)00216-0 ↗
4. 10.1007/s00256005055210.1007/s002560050552 ↗
5. 10.1007/BF0110657310.1007/BF01106573 ↗
6. UlcayY AgarwalV PourdeyhimiB.Elastic properties of 3D randomly distributed spectra 900 and kevlar 49 discontinuous fiber reinforced composites. Proceedings of the 14th Annual Energy Sources Technology Conference and Exhibition Houston ASME;1991. p41–49.
7. 10.1002/jbm.82023010610.1002/jbm.820230106 ↗
8. FriisEA KumarB CookeFW YasudaHK.Fracture toughness of surface‐treated carbon fiber reinforced composite bone cement. Fifth World Biomaterials Congress;1996. p913.
9. 10.1007/BF0013432010.1007/BF00134320 ↗
10. 10.1002/(SICI)1097-4636(199811)42:2<223::AID-JBM7>3.0.CO;2-R10.1002/(SICI)1097-4636(199811)42:2<223::AID-JBM7>3.0.CO;2-R ↗
11. The effect of bone mineral particles on the porosity of bone cement
12. 10.1016/0142-9612(95)98900-Y10.1016/0142-9612(95)98900-Y ↗
13. 10.1002/jbm.82026120610.1002/jbm.820261206 ↗
14. 10.1002/jbm.a.3010710.1002/jbm.a.30107 ↗
15. 10.1002/1097-4636(2000)53:6<717::AID-JBM15>3.0.CO;2-H10.1002/1097-4636(2000)53:6<717::AID-JBM15>3.0.CO;2-H ↗
16. 10.1002/1097-4636(2000)53:6<728::AID-JBM16>3.0.CO;2-A10.1002/1097-4636(2000)53:6<728::AID-JBM16>3.0.CO;2-A ↗
17. 10.1002/(SICI)1097-4636(1999)48:2<121::AID-JBM5>3.0.CO;2-P10.1002/(SICI)1097-4636(1999)48:2<121::AID-JBM5>3.0.CO;2-P ↗
18. 10.1002/(SICI)1097-4636(1999)48:2<135::AID-JBM7>3.0.CO;2-610.1002/(SICI)1097-4636(1999)48:2<135::AID-JBM7>3.0.CO;2-6 ↗
19. 10.1007/BF0012012810.1007/BF00120128 ↗
20. 10.1002/1097-4636(20010305)54:3<419::AID-JBM160>3.0.CO;2-310.1002/1097-4636(20010305)54:3<419::AID-JBM160>3.0.CO;2-3 ↗
21. 10.1023/A:101305772426810.1023/A:1013057724268 ↗
22. 10.1002/(SICI)1097-4636(200001)49:1<127::AID-JBM16>3.0.CO;2-G10.1002/(SICI)1097-4636(200001)49:1<127::AID-JBM16>3.0.CO;2-G ↗
23. 10.1007/978-1-4899-2070-610.1007/978-1-4899-2070-6 ↗
24. 10.1002/1097-4636(20010605)55:3<277::AID-JBM1015>3.0.CO;2-510.1002/1097-4636(20010605)55:3<277::AID-JBM1015>3.0.CO;2-5 ↗
25. 2000 · 46
26. VickersA.Covalently bonding the metal‐bone cement interface in orthopedic implants. Master's Thesis University of Notre Dame Notre Dame IN;2002.
27. 10.1016/S0169-4332(03)00137-510.1016/S0169-4332(03)00137-5 ↗
28. 10.1002/jbm.82024020210.1002/jbm.820240202 ↗
29. 10.1002/jbm.82026120610.1002/jbm.820261206 ↗
30. 10.1016/S1359-6454(99)00071-310.1016/S1359-6454(99)00071-3 ↗
31. 10.1016/j.commatsci.2004.12.02510.1016/j.commatsci.2004.12.025 ↗
32. Strobl GR · 1999
33. ASTM · 1992 · 506
34. Stiffness optimisation of cement and stem materials in total hip replacement
35. 10.1016/S0021-9290(01)00072-010.1016/S0021-9290(01)00072-0 ↗