journal article·2007-09-15

Mechanism of degradation of AgCL coating on biopotential sensors

Chun‐Che Shih, Chun‐Ming Shih, Kuang‐Yi Chou, Shing‐Jong Lin, Yea‐Yang Su, Rosario A. Gerhardt

Publisher page

Abstract

Abstract AgCl coated Ag foil has been widely used as the biopotential sensor to diagnose problems of the human heart. Evidence shows that quality of AgCl on the electrode could experience degradation during the process of long‐term monitoring for irregular activities of the heart. To study the degradation of AgCl/Ag electrode, new and used electrodes were collected. Electrochemical tests such as open‐circuit potential (OCP), cathodic stripping, electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), and X‐ray mapping of elemental distribution were applied to understand the electrochemical properties of the sensors during the progress of degradation. Results revealed that OCP values shift from positive potential of new sensor to negative potential of used sensor (OCPnew: +30 mV; OCPused: −300 mV, p < 0.05) and a significant difference in impedance (Impedancenew: 3000 Ω; Impedanceused: 1 MΩ, p < 0.05). Ratio of the average AgCl thickness on good and bad eletrocardiographic (ECG or EKG) electrodes is 4.83 (p < 0.05). Simulated degradation by exposing the biosensor to deaerated sweat solution and by cathodic stripping of AgCl proposed that the degradation occurs by cathodic reduction of AgCl due to the presence of hydrogen ions in the low pH value of human sweat under deaerated condition. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2007
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Intracranial Aneurysms: Treatment and Complications · Renal and Vascular Pathologies · Vascular Malformations Diagnosis and Treatment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. De viribus electricitatis in motu musculari commentaries De Boloniensi Scient. Et art
2. Sur un phenomene physiologique produit par les muscles en contraction
3. 10.1098/rstb.1889.000410.1098/rstb.1889.0004 ↗
4. 10.1007/BF0166167110.1007/BF01661671 ↗
5. Uber den Dissociationsgrad und das Dissociationsglecichgewicht stark dissociierter electrolyte10.1515/zpch-1900-3337 ↗
6. Geddes LA · 1972
7. 10.1161/01.CIR.35.3.58310.1161/01.CIR.35.3.583 ↗
8. 10.1109/TBME.2004.83650310.1109/TBME.2004.836503 ↗
9. Uric acid and urea in human sweat
10. 10.1046/j.1365-201x.2002.00927.x10.1046/j.1365-201x.2002.00927.x ↗
11. Human skin condition and its associations with nutrient concentrations in serum and diet10.1093/ajcn/77.2.348 ↗
12. 10.2307/317972910.2307/3179729 ↗
13. 10.1007/BF0247466910.1007/BF02474669 ↗
14. 10.1016/0013-4686(95)00442-410.1016/0013-4686(95)00442-4 ↗
15. 10.1002/jbm.a.3043810.1002/jbm.a.30438 ↗
16. Miller HA · 1974
17. 10.1111/j.1749-6632.1968.tb20350.x10.1111/j.1749-6632.1968.tb20350.x ↗
18. 10.1111/j.1749-6632.1968.tb20349.x10.1111/j.1749-6632.1968.tb20349.x ↗
19. 10.1021/cr60166a00210.1021/cr60166a002 ↗
20. Measurement of the direct‐current (Faradaic) resistance of the electrode‐electrolyte interface for commonly used electrode materials