journal article·2014-06

Influence of surface roughness of carbon materials on human osteoblast‐like cell growth

Vladimír Starý, Margita Douděrová, Lucie Bačáková

Publisher page

Abstract

Abstract This article presents a study of the dependence of the biocompatibility of a carbon‐based material, namely a 2D C/C composite, on mechanical and chemical surface modifications. The mechanical modifications were surface grinding and polishing, and chemical modifications were made by depositing thin layers of pyrolytic carbon, titanium‐carbon and DLC layers. Human osteoblast‐like MG 63 cells were cultivated on these materials. The densities of the cells after one‐day cultivation and after four‐day cultivation, and the average cell spreading area after one‐day cultivation, were evaluated in dependence on particular surface roughness parameters. The minima of the cell density on pyrolytic carbon and titanium‐carbon layers were found; they were connected with the maxima of the average cell area. For DLC, the cell area decreased as the roughness parameter Ra increased in the range 0.1–10 µm, although the minimum appeared for the density of the cells. Using a multivariate test, the dependences of the biocompatibility parameters on the layer material and on surface grinding were statistically significant. The results suggest that the optimal roughness parameters for MG 63 cell on carbon based surface were Ra ∼ 3.5 µm, RSm ∼0.03–0.08 mm, Rsk ∼0 or negative and Rku ∼ 20, DLC being the best material choice. These values of roughness were obtained by simple mechanical grinding of substrate and coating by DLC layer. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 1868–1879, 2014.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Cellular Mechanics and Interactions · Bone Tissue Engineering Materials · Graphene and Nanomaterials Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Materials Engineering Faculty of Mechanical Engineering Czech Technical University in Prague Karlovo nám 13, 121 35 Prague 2 Czech Republic

Institute of Physiology, Academy of Sciences Vídeňská 1083, 14220 Prague 4‐Krč Czech Republic

Funding

MSMT research · Czech Science Foundation · Academy of Sciences of the Czech Republic

References (49)

Show source-provided references
1. Black J · 1992
2. 10.1007/978-3-662-06077-310.1007/978-3-662-06077-3 ↗
3. 10.1023/A:100895352911110.1023/A:1008953529111 ↗
4. 10.1016/S0142-9612(03)00403-410.1016/S0142-9612(03)00403-4 ↗
5. Li HJ · 2009 · 620
6. 10.1007/s10856-012-4840-y10.1007/s10856-012-4840-y ↗
7. 10.1016/0142-9612(87)90022-610.1016/0142-9612(87)90022-6 ↗
8. 10.1016/0142-9612(88)90028-210.1016/0142-9612(88)90028-2 ↗
9. 10.1023/B:JMSM.0000010102.26218.d110.1023/B:JMSM.0000010102.26218.d1 ↗
10. 10.1002/1097-4636(20010315)54:4<567::AID-JBM140>3.0.CO;2-Y10.1002/1097-4636(20010315)54:4<567::AID-JBM140>3.0.CO;2-Y ↗
11. 10.1016/S0040-6090(03)00309-210.1016/S0040-6090(03)00309-2 ↗
12. Tribological properties of carbon‐carbon composite and of a surface layer of pyrolytic carbon
13. Pierson HO · 1993
14. Pyrolytic graphite
15. 10.1053/j.jfas.2003.11.00710.1053/j.jfas.2003.11.007 ↗
16. Measurement of surface properties of pyrolytic graphite for biomedical applications
17. 10.1016/S0142-9612(99)00135-010.1016/S0142-9612(99)00135-0 ↗
18. 10.1016/0257-8972(91)90342-T10.1016/0257-8972(91)90342-T ↗
19. 10.1016/S0257-8972(97)00517-310.1016/S0257-8972(97)00517-3 ↗
20. 10.1007/BF0270432010.1007/BF02704320 ↗
21. 10.1002/(SICI)1096-9918(199908)28:1<3::AID-SIA609>3.0.CO;2-U10.1002/(SICI)1096-9918(199908)28:1<3::AID-SIA609>3.0.CO;2-U ↗
22. 10.1016/S0925-9635(00)00462-310.1016/S0925-9635(00)00462-3 ↗
23. 10.1016/S0925-9635(03)00081-510.1016/S0925-9635(03)00081-5 ↗
24. 10.1016/j.biomaterials.2004.02.07110.1016/j.biomaterials.2004.02.071 ↗
25. 10.1016/S0257-8972(02)00619-910.1016/S0257-8972(02)00619-9 ↗
26. 10.1016/j.biomaterials.2004.09.03010.1016/j.biomaterials.2004.09.030 ↗
27. 10.1016/0040-6090(95)06710-810.1016/0040-6090(95)06710-8 ↗
28. 10.1016/S0925-9635(00)00567-710.1016/S0925-9635(00)00567-7 ↗
29. 10.1016/S0142-9612(97)00159-210.1016/S0142-9612(97)00159-2 ↗
30. 10.1016/0925-9635(94)90104-X10.1016/0925-9635(94)90104-X ↗
31. 10.1016/S0257-8972(00)00809-410.1016/S0257-8972(00)00809-4 ↗
32. Whitehouse DJ · 1994
33. 10.1016/0925-9635(95)00481-510.1016/0925-9635(95)00481-5 ↗
34. 10.1089/jmf.2007.066510.1089/jmf.2007.0665 ↗
35. 10.1166/jnn.2009.NS2610.1166/jnn.2009.NS26 ↗
36. 10.1126/science.276.5317.142510.1126/science.276.5317.1425 ↗
37. 10.1007/s11626-999-0050-410.1007/s11626-999-0050-4 ↗
38. Cell adhesion on artificial materials for tissue engineering10.33549/physiolres.930000.53.S35 ↗
39. 10.1016/j.biotechadv.2011.06.00410.1016/j.biotechadv.2011.06.004 ↗
40. 10.1016/j.diamond.2005.10.01010.1016/j.diamond.2005.10.010 ↗
41. 10.1002/jbm.a.3032110.1002/jbm.a.30321 ↗
42. The effect of titanium surface roughening on protein absorption, cell attachment, and cell spreading
43. 10.1016/j.biomaterials.2005.10.00910.1016/j.biomaterials.2005.10.009 ↗
44. 10.4028/www.scientific.net/MSF.426-432.303110.4028/www.scientific.net/MSF.426-432.3031 ↗
45. 10.1016/S0142-9612(03)00152-210.1016/S0142-9612(03)00152-2 ↗
46. Metal‐containing amorphous carbon films for hydrophobic application
47. 10.1016/j.diamond.2008.05.00410.1016/j.diamond.2008.05.004 ↗
48. 10.1016/j.apsusc.2008.06.19210.1016/j.apsusc.2008.06.192 ↗
49. 10.1016/S0142-9612(98)00144-610.1016/S0142-9612(98)00144-6 ↗