Woven collagen biotextiles enable mechanically functional rotator cuff tendon regeneration during repair of segmental tendon defects in vivo
Source abstract
Abstract
Abstract Despite advancements in surgical techniques and materials for rotator cuff repair procedures, primary repair failures remain common. This study examines the use of electrochemically aligned collagen (ELAC) threads woven into biotextile scaffolds as grafts to repair critical infraspinatus tendon defects in New Zealand White rabbits. Three surgical treatment groups were evaluated: rabbits undergoing direct repair as operative controls, rabbits receiving ELAC scaffolds alone, and rabbits treated with mesenchymal stem cell (MSC)‐seeded ELAC scaffolds. In each animal, the intact, contralateral infraspinatus served as an internal positive control. Tendon–bone constructs were harvested after 3 months in vivo and outcome measures included biomechanical testing, histological staining, and immunohistochemical staining. Biomechanical testing revealed that maximum load‐bearing capacity was comparable between all groups, while MSC‐seeded scaffold repairs exhibited increased stiffness relative to non‐seeded scaffold repairs. Histological staining revealed robust collagen deposition around ELAC fibers and increased cellularity within the continuum of woven scaffolds as compared to native tendon. Immunohistochemical staining revealed presence of collagens I and III in all groups, but procollagen I and the tendon‐specific marker tenomodulin were only observed in seeded and non‐seeded ELAC scaffold repairs. Findings of this pilot study warrant continued investigation of ELAC biotextile scaffolds for repair of critically‐sized rotator cuff tendon defects. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1864–1876, 2019.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Shoulder Injury and Treatment · Tendon Structure and Treatment · Surgical Sutures and Adhesives
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Biomedical Engineering Case Western Reserve University Cleveland Ohio
Department of Mechanical and Aerospace Engineering Case Western Reserve University Cleveland Ohio
Department of Orthopaedic Surgery University Hospitals of Cleveland Cleveland Ohio
School of Medicine, Case Western Reserve University Cleveland Ohio
Department of Pathology Case Western Reserve University Cleveland Ohio
Department of Macromolecular Science Case Western Reserve University Cleveland Ohio
Funding
National Institutes of Health
References (51)
Show source-provided references
1. 10.2106/00004623-200402000-0000210.2106/00004623-200402000-00002 ↗
2. 10.2106/JBJS.L.0149510.2106/JBJS.L.01495 ↗
3. 10.1177/036354651452964410.1177/0363546514529644 ↗
4. 10.1177/036354650629753910.1177/0363546506297539 ↗
5. 10.1590/1413-78522015230511982110.1590/1413-785220152305119821 ↗
6. Fatty infiltration does not progress after rotator cuff repair in a rabbit model
7. 10.1007/s00167-014-3445-z10.1007/s00167-014-3445-z ↗
8. 10.1089/ten.2006.026610.1089/ten.2006.0266 ↗
9. 10.1016/j.jse.2009.10.02010.1016/j.jse.2009.10.020 ↗
10. 10.1007/s00167-014-2923-710.1007/s00167-014-2923-7 ↗
11. 10.5435/JAAOS-D-15-0022910.5435/JAAOS-D-15-00229 ↗
12. 10.1016/j.arthro.2012.05.88710.1016/j.arthro.2012.05.887 ↗
13. 10.1186/1758-2555-3-2910.1186/1758-2555-3-29 ↗
14. 10.1177/036354650831441610.1177/0363546508314416 ↗
15. 10.1016/j.jse.2012.11.00510.1016/j.jse.2012.11.005 ↗
16. 10.1016/j.csm.2008.09.00210.1016/j.csm.2008.09.002 ↗
17. 10.1177/036354651036123510.1177/0363546510361235 ↗
18. 10.1177/036354651039548510.1177/0363546510395485 ↗
19. 10.1177/036354651037933910.1177/0363546510379339 ↗
20. 10.1089/10763270376268762710.1089/107632703762687627 ↗
21. 10.1111/jcmm.1318610.1111/jcmm.13186 ↗
22. 10.1016/j.actbio.2017.08.04310.1016/j.actbio.2017.08.043 ↗
23. 10.1002/jor.2045610.1002/jor.20456 ↗
24. 10.1089/ten.2005.11.44810.1089/ten.2005.11.448 ↗
25. 10.1089/ten.2006.12.36910.1089/ten.2006.12.369 ↗
26. 10.1016/j.biomaterials.2008.04.02810.1016/j.biomaterials.2008.04.028 ↗
27. 10.1002/jbm.b.3196210.1002/jbm.b.31962 ↗
28. 10.1002/adfm.20140082810.1002/adfm.201400828 ↗
29. 10.1088/1748-6041/6/3/03500810.1088/1748-6041/6/3/035008 ↗
30. 10.1016/j.biomaterials.2011.11.06610.1016/j.biomaterials.2011.11.066 ↗
31. 10.1089/ten.1999.5.26710.1089/ten.1999.5.267 ↗
32. 10.5966/sctm.2015-021510.5966/sctm.2015-0215 ↗
33. 10.1038/cddis.2015.32710.1038/cddis.2015.327 ↗
34. 10.1002/sctm.17-005110.1002/sctm.17-0051 ↗
35. 10.1371/journal.pone.011139010.1371/journal.pone.0111390 ↗
36. 10.2106/00004623-198668050-0002010.2106/00004623-198668050-00020 ↗
37. 10.1177/03635465970250042010.1177/036354659702500420 ↗
38. 10.1016/j.clinbiomech.2015.05.00710.1016/j.clinbiomech.2015.05.007 ↗
39. ISO 10993‐6:2016. Biological evaluation of medical devices—Part 6: Tests for local effects after implantation [Internet] [cited November 2 2017].https://www.iso.org/standard/61089.html.
40. ASTM F981‐04 · 2016
41. 10.1097/00003086-199507000-0002110.1097/00003086-199507000-00021 ↗
42. 10.3727/096368911X62745310.3727/096368911X627453 ↗
43. 10.1016/j.actbio.2017.01.04110.1016/j.actbio.2017.01.041 ↗
44. 10.1016/j.biomaterials.2014.12.02710.1016/j.biomaterials.2014.12.027 ↗
45. 10.1177/036354650427150010.1177/0363546504271500 ↗
46. 10.1089/ten.tec.2010.045710.1089/ten.tec.2010.0457 ↗
47. 10.1007/s10856-012-4791-310.1007/s10856-012-4791-3 ↗
48. 10.1002/j.2048-7940.1994.tb01578.x10.1002/j.2048-7940.1994.tb01578.x ↗
49. 10.1016/j.jse.2004.04.00710.1016/j.jse.2004.04.007 ↗
50. 10.1007/s00402005038310.1007/s004020050383 ↗
51. 10.1016/j.jcyt.2012.08.00110.1016/j.jcyt.2012.08.001 ↗