journal article·2012-04

Ni ion release, osteoblast–material interactions, and hemocompatibility of hafnium‐implanted NiTi alloy

Tingting Zhao, Yan Li, Xinqing Zhao, Hong Chen, Tao Zhang

Publisher page

Abstract

Abstract Hafnium ion implantation was applied to NiTi alloy to suppress Ni ion release and enhance osteoblast–material interactions and hemocompatibility. The auger electron spectroscopy, x‐ray photoelectron spectroscopy, and atomic force microscope results showed that a composite TiO2/HfO2 nanofilm with increased surface roughness was formed on the surface of NiTi, and Ni concentration was reduced in the superficial surface layer. Potentiodynamic polarization tests displayed that 4 mA NiTi sample possessed the highest Ebr − Ecorr, 470 mV higher than that of untreated NiTi, suggesting a significant improvement on pitting corrosion resistance. Inductively coupled plasma mass spectrometry tests during 60 days immersion demonstrated that Ni ion release rate was remarkably decreased, for example, a reduction of 67% in the first day. The water contact angle increased and surface energy decreased after Hf implantation. Cell culture and methyl‐thiazol‐tetrazolium indicated that Hf‐implanted NiTi expressed enhanced osteoblasts adhesion and proliferation, especially after 7 days culture. Hf implantation decreased fibrinogen adsorption, but had almost no effect on albumin adsorption. Platelets adhesion and activation were suppressed significantly (97% for 4 mA NiTi) and hemolysis rate was decreased by at least 57% after Hf implantation. Modified surface composition and morphology and decreased surface energy should be responsible for the improvement of cytocompatibility and hemocompatibility. © 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2012.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Metal and Thin Film Mechanics · Titanium Alloys Microstructure and Properties · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (46)

Show source-provided references
1. 10.1016/j.pmatsci.2008.06.00410.1016/j.pmatsci.2008.06.004 ↗
2. 10.1016/j.biomaterials.2005.01.06710.1016/j.biomaterials.2005.01.067 ↗
3. 10.1016/j.biomaterials.2008.04.02310.1016/j.biomaterials.2008.04.023 ↗
4. 10.1016/j.colsurfb.2008.08.00810.1016/j.colsurfb.2008.08.008 ↗
5. 10.1016/j.biomaterials.2008.09.01110.1016/j.biomaterials.2008.09.011 ↗
6. 10.1016/j.biomaterials.2003.12.00110.1016/j.biomaterials.2003.12.001 ↗
7. 10.1016/S0142-9612(00)00368-910.1016/S0142-9612(00)00368-9 ↗
8. 10.1002/jbm.b.3044110.1002/jbm.b.30441 ↗
9. 10.1016/j.actbio.2011.01.00410.1016/j.actbio.2011.01.004 ↗
10. 10.1021/la700299610.1021/la7002996 ↗
11. 10.1016/j.biomaterials.2008.08.01410.1016/j.biomaterials.2008.08.014 ↗
12. 10.1016/j.biomaterials.2004.07.05610.1016/j.biomaterials.2004.07.056 ↗
13. 10.1016/j.surfcoat.2006.07.00410.1016/j.surfcoat.2006.07.004 ↗
14. 10.1002/jbm.a.3020110.1002/jbm.a.30201 ↗
15. Ryhänen J · 1999
16. 10.1016/S0257-8972(02)00048-810.1016/S0257-8972(02)00048-8 ↗
17. 10.1002/jbm.a.3145910.1002/jbm.a.31459 ↗
18. 10.1016/S0257-8972(03)00745-X10.1016/S0257-8972(03)00745-X ↗
19. 10.1016/j.msec.2010.07.00110.1016/j.msec.2010.07.001 ↗
20. 10.1007/s10853-010-5104-110.1007/s10853-010-5104-1 ↗
21. 10.1016/S0142-9612(00)00275-110.1016/S0142-9612(00)00275-1 ↗
22. BS EN ISO 10993‐12 · 2004
23. 10.1016/S0928-4931(03)00033-X10.1016/S0928-4931(03)00033-X ↗
24. 10.1007/978-1-4899-1176-6_910.1007/978-1-4899-1176-6_9 ↗
25. National Institutes of Health. In: Image J home. Download. Available athttp://rsb.info.nih.gov/ij/download.html. Accessed 27 Sep. 2006.
26. 10.1016/j.biomaterials.2004.07.06810.1016/j.biomaterials.2004.07.068 ↗
27. 10.1016/j.susc.2009.01.04010.1016/j.susc.2009.01.040 ↗
28. 10.1016/j.actbio.2008.07.03110.1016/j.actbio.2008.07.031 ↗
29. 10.1006/adnd.1996.000510.1006/adnd.1996.0005 ↗
30. 10.1007/978-0-387-84872-310.1007/978-0-387-84872-3 ↗
31. Frankel GS · 2003 · 236
32. 10.1016/j.colsurfb.2006.02.01610.1016/j.colsurfb.2006.02.016 ↗
33. 10.1002/(SICI)1097-4636(19990605)45:3<240::AID-JBM12>3.0.CO;2-C10.1002/(SICI)1097-4636(19990605)45:3<240::AID-JBM12>3.0.CO;2-C ↗
34. ASTMF 756‐00;Standard practice for assessment of hemolytic properties of materials.Pennsylvania:ASTM International;2000.
35. 10.1016/j.biomaterials.2009.03.03410.1016/j.biomaterials.2009.03.034 ↗
36. 10.1016/j.actbio.2009.01.04610.1016/j.actbio.2009.01.046 ↗
37. 10.1016/j.surfcoat.2007.07.09310.1016/j.surfcoat.2007.07.093 ↗
38. 10.1016/j.nantod.2010.01.00110.1016/j.nantod.2010.01.001 ↗
39. 10.1007/s00223990064010.1007/s002239900640 ↗
40. 10.1016/j.actbio.2008.01.01310.1016/j.actbio.2008.01.013 ↗
41. 10.1016/0021-9797(86)90019-610.1016/0021-9797(86)90019-6 ↗
42. TanL BauerJ CroneWC AlbrechtRM. Biocompatibility improvement of NiTi with a functionally graded surface. In: Proceedings of the 2002 SEM Annual Conference & Exposition on Experimental and Applied Mechanics. Milwaukee WI: Society for Experimental Mechanics Inc;2002. p131–134.
43. 10.1002/jbm.82011010710.1002/jbm.820110107 ↗
44. 10.1016/S0142-9612(01)00389-110.1016/S0142-9612(01)00389-1 ↗
45. 10.1002/sia.110110.1002/sia.1101 ↗
46. 10.1002/jbm.a.1054910.1002/jbm.a.10549 ↗