journal article·2019-08

Evaluation of magnesium alloys for use as an intraluminal tracheal for pediatric applications in a rat tracheal bypass model

Sarah A. Luffy, Jingyao Wu, Prashant N. Kumta, Thomas W. Gilbert

Publisher page

Abstract

Abstract Tracheal stenting currently using non‐degradable stents is commonplace for treatment of trauma, prolonged intubation related adult airway obstructions, and pediatric patients‐associated tracheal stenosis conditions. Degradable tracheal stent placement will avoid complications of stent removal and restenosis. Widespread reports exist on degradable magnesium alloys success for orthopedic and cardiovascular applications but none to date for intra tracheal use. This research explores the use of pure Mg, AZ31, and Mg‐3Y alloys for degradable tracheal stent assessment. In vitro evaluation of magnesium, prototype stents in a bioreactor simulate the airway environment and corrosion. Micro‐CT imaging and biocompatibility evaluation helped assess the 24‐week degradation of intraluminal alloy stents following implantation in a rat tracheal in vivo bypass model. Histological analysis indicate tissue response of the harvested stented trachea segments after each time point. Corrosion studies for each alloy indicate significant differences between the simulated and control in vitro conditions. AZ31 exhibited the lowest volume loss of 6.8% in saline, while pure Mg displayed the lowest volume loss of 4.6% in simulated airway fluid (SAF), both at 1‐week time points. Significant differences in percentage of total volume lost after 6 months were determined between the alloys over time. MgY alloy displayed the slowest corrosion losing only 15.1% volume after 24 weeks of immersion. Additionally, in vitro magnesium alloy corrosion was not significantly different from the percentage of total volume lost in vivo at 1‐week time point. The study demonstrates promise of magnesium alloys for intraluminal tracheal stent application albeit viability of a clinically translatable model warrants further studies. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1844–1853, 2019.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Hydrogen Storage and Materials · Tracheal and airway disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Bioengineering University of Pittsburgh Pittsburgh Pennsylvania 15261

McGowan Institute of Regenerative Medicine University of Pittsburgh Pittsburgh Pennsylvania 15261

Department of Mechanical Engineering and Materials Science University of Pittsburgh Pittsburgh Pennsylvania 15261

Department of Chemical and Petroleum Engineering University of Pittsburgh Pittsburgh Pennsylvania 15261

Department of Oral Biology, School of Dental Medicine University of Pitsburgh Pennsylvania 15261

Department of Cardiothoracic Surgery Children's Hospital of Pittsburgh of UPMC Pittsburgh Pennsylvania

ACell, Inc. Columbia MD 21046

Funding

Division of Chemical, Bioengineering, Environmental, and Transport Systems · Division of Engineering Education and Centers · University of Pittsburgh · National Science Foundation

References (25)

Show source-provided references
1. 10.1097/01.RVI.0000194964.53892.EC10.1097/01.RVI.0000194964.53892.EC ↗
2. 10.1016/j.jpedsurg.2007.10.05710.1016/j.jpedsurg.2007.10.057 ↗
3. 10.1159/00033429910.1159/000334299 ↗
4. 10.1093/icvts/ivs01810.1093/icvts/ivs018 ↗
5. 10.1016/j.jpedsurg.2010.02.03510.1016/j.jpedsurg.2010.02.035 ↗
6. 10.1016/j.ejcts.2008.01.03410.1016/j.ejcts.2008.01.034 ↗
7. 10.1097/MOO.0b013e3282f433f410.1097/MOO.0b013e3282f433f4 ↗
8. 10.1016/j.athoracsur.2011.12.06310.1016/j.athoracsur.2011.12.063 ↗
9. The management of post‐intubation tracheal stenoses with self‐expandable stents: early and long‐term results in 11 cases
10. 10.1097/MOO.0b013e328358566d10.1097/MOO.0b013e328358566d ↗
11. 10.1002/ppul.2079010.1002/ppul.20790 ↗
12. 10.1007/s11748-007-0131-910.1007/s11748-007-0131-9 ↗
13. Severe respiratory distress caused by central airway obstruction treated with self‐expandable metallic stents
14. 10.3390/ijms1207425010.3390/ijms12074250 ↗
15. 10.1016/j.scriptamat.2008.03.00110.1016/j.scriptamat.2008.03.001 ↗
16. 10.1016/j.scriptamat.2007.10.03910.1016/j.scriptamat.2007.10.039 ↗
17. 10.1016/j.actbio.2009.10.00810.1016/j.actbio.2009.10.008 ↗
18. 10.1016/j.biomaterials.2007.12.02110.1016/j.biomaterials.2007.12.021 ↗
19. 10.1016/j.biomaterials.2008.02.00310.1016/j.biomaterials.2008.02.003 ↗
20. 10.1016/j.msec.2014.05.01410.1016/j.msec.2014.05.014 ↗
21. 10.1016/j.biomaterials.2015.02.09610.1016/j.biomaterials.2015.02.096 ↗
22. 10.1002/jbm.a.3473110.1002/jbm.a.34731 ↗
23. 10.1016/j.actbio.2013.02.02010.1016/j.actbio.2013.02.020 ↗
24. 10.14227/DT180311P1510.14227/DT180311P15 ↗
25. 10.1016/j.biomaterials.2005.07.03710.1016/j.biomaterials.2005.07.037 ↗