journal article·2023-02

Impact of surface roughness and bulk porosity on spinal interbody implants

Hannah A. Levy, Brian A. Karamian, Goutham R. Yalla, Jose A. Canseco, Alexander R. Vaccaro, Christopher K. Kepler

Publisher page

Abstract

Abstract Spinal fusion surgeries are performed to treat a multitude of cervical and lumbar diseases that lead to pain and disability. Spinal interbody fusion involves inserting a cage between the spinal vertebrae, and is often utilized for indirect neurologic decompression, correction of spinal alignment, anterior column stability, and increased fusion rate. The long‐term success of interbody fusion relies on complete osseointegration between the implant surface and vertebral end plates. Titanium (Ti)‐based alloys and polyetheretherketone (PEEK) interbody cages represent the most commonly utilized materials and provide sufficient mechanics and biocompatibility to assist in fusion. However, modification to the surface and bulk characteristics of these materials has been shown to maximize osseointegration and long‐term stability. Specifically, the introduction of intrinsic porosity and surface roughness has been shown to affect spinal interbody mechanics, vascularization, osteoblast attachment, and ingrowth potential. This narrative review synthesizes the mechanical, in vitro, in vivo, and clinical effects on fusion efficacy associated with introduction of porosity in Ti (neat and alloy) and PEEK intervertebral implants.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Spine and Intervertebral Disc Pathology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Orthopaedic Surgery, Rothman Institute Thomas Jefferson University Philadelphia Pennsylvania USA

Department of Orthopaedic Surgery Mayo Clinic Rochester Minnesota

Department of Orthopaedic Surgery University of Utah Salt Lake City USA

References (85)

Show source-provided references
1. Fingar KR · 2014
2. 10.1097/00007632-200308011-0000210.1097/00007632-200308011-00002 ↗
3. Lumbar interbody fusion: techniques, indications and comparison of interbody fusion options including PLIF, TLIF, MI‐TLIF, OLIF/ATP, LLIF and ALIF
4. 10.1111/os.1209810.1111/os.12098 ↗
5. 10.1007/s00586010028210.1007/s005860100282 ↗
6. 10.1097/BRS.000000000000033610.1097/BRS.0000000000000336 ↗
7. 10.1016/j.jocn.2017.06.06210.1016/j.jocn.2017.06.062 ↗
8. 10.14245/ns.1938296.14810.14245/ns.1938296.148 ↗
9. 10.1016/j.nec.2019.08.00710.1016/j.nec.2019.08.007 ↗
10. 10.1007/s12178-020-09673-510.1007/s12178-020-09673-5 ↗
11. 10.1016/j.pmatsci.2008.06.00410.1016/j.pmatsci.2008.06.004 ↗
12. 10.1002/bit.2514610.1002/bit.25146 ↗
13. Titanium in medicine, material science, surface science, engineering, biological responses and medical applications
14. 10.1016/j.compbiomed.2018.02.01610.1016/j.compbiomed.2018.02.016 ↗
15. 10.1097/BSD.000000000000084310.1097/BSD.0000000000000843 ↗
16. 10.1097/BSD.0b013e3181af3a8410.1097/BSD.0b013e3181af3a84 ↗
17. 10.1080/1745367061004590210.1080/17453670610045902 ↗
18. 10.1016/j.jmbbm.2007.07.00110.1016/j.jmbbm.2007.07.001 ↗
19. 10.1016/j.jmbbm.2018.01.01710.1016/j.jmbbm.2018.01.017 ↗
20. 10.3174/ajnr.A441610.3174/ajnr.A4416 ↗
21. 10.1016/B978-1-4377-4463-7.10001-610.1016/B978-1-4377-4463-7.10001-6 ↗
22. 10.1016/j.biomaterials.2007.07.01310.1016/j.biomaterials.2007.07.013 ↗
23. 10.1097/BTO.000000000000024210.1097/BTO.0000000000000242 ↗
24. 10.1557/jmr.2018.17810.1557/jmr.2018.178 ↗
25. Polyetheretherketone for long‐term implantable devices
26. 10.1016/j.jmbbm.2020.10399610.1016/j.jmbbm.2020.103996 ↗
27. 10.1016/j.jmbbm.2016.09.00610.1016/j.jmbbm.2016.09.006 ↗
28. 10.1016/j.bone.2007.09.05510.1016/j.bone.2007.09.055 ↗
29. 10.14245/ns.1836192.09610.14245/ns.1836192.096 ↗
30. 10.1016/j.msec.2019.10994810.1016/j.msec.2019.109948 ↗
31. 10.1007/s11999-016-4833-010.1007/s11999-016-4833-0 ↗
32. 10.1016/j.actbio.2014.11.03010.1016/j.actbio.2014.11.030 ↗
33. 10.1016/j.biomaterials.2012.08.05910.1016/j.biomaterials.2012.08.059 ↗
34. 10.1016/j.actbio.2014.03.03710.1016/j.actbio.2014.03.037 ↗
35. 10.1016/j.biomaterials.2011.01.02910.1016/j.biomaterials.2011.01.029 ↗
36. 10.1016/j.actbio.2012.12.00210.1016/j.actbio.2012.12.002 ↗
37. 10.1097/BRS.000000000000077810.1097/BRS.0000000000000778 ↗
38. 10.1016/j.actbio.2016.01.02210.1016/j.actbio.2016.01.022 ↗
39. Comparison of short‐term Radiographical and clinical outcomes after posterior lumbar interbody fusion with a 3D porous titanium alloy cage and a titanium‐coated PEEK cage
40. 10.1007/s00586-020-06673-410.1007/s00586-020-06673-4 ↗
41. 10.1007/s10856-013-4998-y10.1007/s10856-013-4998-y ↗
42. Mechanical and in vitro investigation of a porous PEEK foam for medical device implants
43. 10.1073/pnas.20229659910.1073/pnas.202296599 ↗
44. 10.1073/pnas.080542010510.1073/pnas.0805420105 ↗
45. 10.1097/BRS.000000000000330310.1097/BRS.0000000000003303 ↗
46. 10.3390/molecules2516357210.3390/molecules25163572 ↗
47. 10.1016/j.biomaterials.2018.09.00910.1016/j.biomaterials.2018.09.009 ↗
48. 10.1016/j.jmbbm.2014.05.02910.1016/j.jmbbm.2014.05.029 ↗
49. 10.1088/1758-5082/6/4/04500710.1088/1758-5082/6/4/045007 ↗
50. 10.1097/BRS.000000000000167210.1097/BRS.0000000000001672 ↗
51. 10.1007/s10856-015-5565-510.1007/s10856-015-5565-5 ↗
52. 10.1016/j.biomaterials.2005.12.00210.1016/j.biomaterials.2005.12.002 ↗
53. 10.1016/j.wneu.2017.12.12710.1016/j.wneu.2017.12.127 ↗
54. 10.1016/j.jmbbm.2015.02.02310.1016/j.jmbbm.2015.02.023 ↗
55. 10.1016/S1003-6326(13)62735-110.1016/S1003-6326(13)62735-1 ↗
56. 10.1007/s00586-011-1728-310.1007/s00586-011-1728-3 ↗
57. 10.1016/j.spinee.2020.03.00810.1016/j.spinee.2020.03.008 ↗
58. 10.1016/j.spinee.2018.02.01810.1016/j.spinee.2018.02.018 ↗
59. 10.1111/aor.1215310.1111/aor.12153 ↗
60. 10.1007/s00586-015-4047-210.1007/s00586-015-4047-2 ↗
61. 10.1016/j.spinee.2018.01.00310.1016/j.spinee.2018.01.003 ↗
62. 10.1016/0043-1648(93)90329-K10.1016/0043-1648(93)90329-K ↗
63. 10.1007/s40204-019-00123-110.1007/s40204-019-00123-1 ↗
64. 10.1016/j.jmbbm.2020.10373010.1016/j.jmbbm.2020.103730 ↗
65. 10.1016/j.biomaterials.2006.08.01310.1016/j.biomaterials.2006.08.013 ↗
66. 10.1023/A:101434481955810.1023/A:1014344819558 ↗
67. 10.1016/j.biomaterials.2005.02.00210.1016/j.biomaterials.2005.02.002 ↗
68. 10.1002/jbm.b.1053010.1002/jbm.b.10530 ↗
69. 10.1002/jbm.b.1053110.1002/jbm.b.10531 ↗
70. 10.1007/s10856-006-6822-410.1007/s10856-006-6822-4 ↗
71. 10.1016/j.jmbbm.2020.10385010.1016/j.jmbbm.2020.103850 ↗
72. 10.1002/jbm.a.3665210.1002/jbm.a.36652 ↗
73. 10.3390/polym1208166510.3390/polym12081665 ↗
74. 10.1177/15440591070860100610.1177/154405910708601006 ↗
75. 10.1002/jbm.a.3026310.1002/jbm.a.30263 ↗
76. 10.1016/j.actbio.2016.07.00310.1016/j.actbio.2016.07.003 ↗
77. 10.1016/j.biomaterials.2016.10.01910.1016/j.biomaterials.2016.10.019 ↗
78. 10.1179/175355510X1274441270940310.1179/175355510X12744412709403 ↗
79. 10.3390/ijms1604747810.3390/ijms16047478 ↗
80. 10.5772/6537510.5772/65375 ↗
81. 10.1016/j.jmbbm.2020.10424310.1016/j.jmbbm.2020.104243 ↗
82. 10.22603/ssrr.2019-008910.22603/ssrr.2019-0089 ↗
83. Early outcomes of anterior cervical discectomy and fusion using a porous PEEK interbody fusion device
84. Early clinical outcomes comparing porous PEEK, smooth PEEK, and structural allograft interbody devices for anterior cervical discectomy and fusion
85. 10.1186/1471-2474-14-24410.1186/1471-2474-14-244 ↗