Charge injection characteristics of sputtered ruthenium oxide electrodes for neural stimulation and recording
Source abstract
Abstract
Abstract We have studied the charge‐injection characteristics and electrochemical impedance of sputtered ruthenium oxide (RuOx) films as electrode coatings for neural stimulation and recording electrodes. RuOx films were deposited by reactive DC magnetron sputtering, using a combination of water vapor and oxygen gas as reactive plasma constituents. The cathodal charge storage capacity of planar RuOx electrodes was found to be 54.6 ± 9.5 mC/cm2 (mean ± SD, n = 12), and the charge‐injection capacity in a 0.2‐ms cathodal current pulse was found to be 7.1 ± 0.3 mC/cm2 (mean ± SD, n = 15) at 0.6 V positive bias versus Ag|AgCl, in phosphate buffer saline at room temperature for ~250 nm thick films. In general, the RuOx films exhibited high charge‐injection capacities, with or without a positive interpulse bias, comparable to sputtered iridium oxide (SIROF) coatings. The charge‐injection capacity increased monotonically with film thickness from 120 to 630 nm, and reached 11.30 ± 0.34 mC/cm2 (mean ± SD, n = 5) at 0.6 V bias versus Ag|AgCl at 630 nm film thickness. In addition, RuOx films showed minimal changes in electrochemical characteristics over 1.5 billion cycles of constant current pulsing at a charge density of 408 μC/cm2 (8 nC/phase, 200 μs pulse width). The findings of low‐impedance, high charge‐injection capacity, and long‐term pulsing stability suggest the suitability of RuOx as a comparatively inexpensive and favorable choice of electrode material for neural stimulation and recording.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Neuroscience and Neural Engineering · Advanced Memory and Neural Computing · Conducting polymers and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Materials Science and Engineering The University of Texas at Dallas Richardson Texas USA
Department of Research The University of Texas at Dallas Richardson Texas USA
Department of Bioengineering The University of Texas at Dallas Richardson Texas USA
Funding
National Institutes of Health
References (44)
Show source-provided references
1. 10.1126/scitranslmed.aaf808310.1126/scitranslmed.aaf8083 ↗
2. 10.1109/TNSRE.2005.85607210.1109/TNSRE.2005.856072 ↗
3. 10.1007/978-3-319-47313-0_2010.1007/978-3-319-47313-0_20 ↗
4. 10.7554/eLife.3290410.7554/eLife.32904 ↗
5. 10.1016/S0042-6989(03)00457-710.1016/S0042-6989(03)00457-7 ↗
6. 10.1152/jn.01213.200310.1152/jn.01213.2003 ↗
7. 10.1146/annurev.bioeng.10.061807.16051810.1146/annurev.bioeng.10.061807.160518 ↗
8. 10.1016/j.jneumeth.2004.10.02010.1016/j.jneumeth.2004.10.020 ↗
9. 10.1088/1748-6041/5/1/01500710.1088/1748-6041/5/1/015007 ↗
10. 10.1109/10.6103810.1109/10.61038 ↗
11. 10.1016/j.jneumeth.2009.10.01610.1016/j.jneumeth.2009.10.016 ↗
12. 10.1088/1741-2560/10/6/06601410.1088/1741-2560/10/6/066014 ↗
13. 10.1021/jp990096n10.1021/jp990096n ↗
14. 10.1155/2018/127376810.1155/2018/1273768 ↗
15. 10.1016/j.snb.2018.07.02210.1016/j.snb.2018.07.022 ↗
16. 10.3390/ma806335210.3390/ma8063352 ↗
17. 10.1149/1.135995610.1149/1.1359956 ↗
18. 10.1016/j.cap.2010.12.00110.1016/j.cap.2010.12.001 ↗
19. NygrenLA ColesJrJA BrabecSJ RoseRG Medtronic Inc.Method for fabrication of low‐polarization implantable stimulation electrode. US Patent 8155754.2012.
20. 10.1002/jbm.b.3472810.1002/jbm.b.34728 ↗
21. 10.1002/jbm.b.3444210.1002/jbm.b.34442 ↗
22. 10.1088/1741-2560/4/2/00810.1088/1741-2560/4/2/008 ↗
23. 10.1002/jbm.b.3122310.1002/jbm.b.31223 ↗
24. 10.1116/1.131273210.1116/1.1312732 ↗
25. 10.1146/annurev.ms.07.080177.00132310.1146/annurev.ms.07.080177.001323 ↗
26. 10.1116/1.57260410.1116/1.572604 ↗
27. 10.1063/1.133758810.1063/1.1337588 ↗
28. 10.1149/1.186567310.1149/1.1865673 ↗
29. 10.1016/j.surfcoat.2017.01.00610.1016/j.surfcoat.2017.01.006 ↗
30. 10.1149/2.0401809jes10.1149/2.0401809jes ↗
31. 10.1109/TBME.2002.80548710.1109/TBME.2002.805487 ↗
32. 10.1016/0925-4005(90)80218-O10.1016/0925-4005(90)80218-O ↗
33. 10.1021/jp026228l10.1021/jp026228l ↗
34. 10.1016/0925-4005(95)01655-410.1016/0925-4005(95)01655-4 ↗
35. 10.1016/j.electacta.2012.04.14310.1016/j.electacta.2012.04.143 ↗
36. 10.1016/S0022-0728(01)00562-910.1016/S0022-0728(01)00562-9 ↗
37. 10.1149/1.193337210.1149/1.1933372 ↗
38. 10.1016/S0006-8993(98)00977-910.1016/S0006-8993(98)00977-9 ↗
39. 10.1016/0378-5955(90)90173-M10.1016/0378-5955(90)90173-M ↗
40. 10.1088/1741-2552/ab52ab10.1088/1741-2552/ab52ab ↗
41. 10.1088/1741-2560/12/6/06601810.1088/1741-2560/12/6/066018 ↗
42. 10.1016/S0079-6123(09)17524-610.1016/S0079-6123(09)17524-6 ↗
43. 10.1109/TBME.2013.224815210.1109/TBME.2013.2248152 ↗
44. 10.1016/j.actbio.2019.10.04010.1016/j.actbio.2019.10.040 ↗