Failure analysis of two Ti‐alloy total hip arthroplasty femoral stems fractured in vivo
Source abstract
Abstract
Abstract Failure of total hip arthroplasty femoral stems is a serious clinical complication. Even modern metal alloys and designs sometimes suffer such incidents. The reported study aimed at the investigation of the reasons leading the in vivo fracture of two Ti6Al4V femoral stems. Stems were retrieved during revision surgery approximately 2 years postoperatively. Examination and analysis included XRF spectrometry for identification of chemical composition, macroscopic examination and topographical measurements, SEM study of fracture surfaces, study of alloy microstructure by optical microscopy, and finally measurement of mechanical properties by means of tensile testing conducted on alloy samples machined from the stems themselves. Macroscopic examination and measurements showed close topographical similarity between the two fractures. XRF spectrometry, tensile testing, and microstructure analysis identified the alloy as a typical Ti6Al4V surgical titanium alloy. During SEM analysis the fracture surfaces exhibited characteristic fatigue striations tidally running on the cross sections, which were considered as the weakest ones regarding toward geometry and stress concentration. Fracture in both stems occurred due to fatigue along these cross sections. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 66B: 299–305, 2003
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. Failed femoral stems in total hip prostheses10.2106/00004623-197557020-00017 ↗
2. Femoral stem failure in total hip replacement10.2106/00004623-197759080-00006 ↗
3. Fracture failure of a forged vitallium prosthesis10.2106/00004623-198264090-00012 ↗
4. Fatigue fracture of a forged cobalt–chromium–molybdenum femoral component inserted with cement10.2106/00004623-199712000-00010 ↗
5. Catastrophic failure of a cemented, collarless, polished, tapered cobalt–chromium femoral stem used with impaction bone‐grafting10.2106/00004623-199906000-00011 ↗
6. Modes of failure of cemented stem‐type femoral components
7. Causes of fractures of the femoral component in total hip replacement10.2106/00004623-198062040-00026 ↗
8. 10.1016/S0142-9612(97)00146-410.1016/S0142-9612(97)00146-4 ↗
9. ISO6892.Metallic materials—Tensile testing.Geneva:International Organization for Standardization;1984.
10. F 1472.Standard specification for wrought Ti6Al4V alloy for surgical implant applications.Pittsburgh PA:American Society for Testing and Materials;1993
11. ISO6871‐1.Dental base metal casting alloys. Part 1: Cobalt‐based alloys.Geneva:International Organization for Standardization;1994.
12. ISO5832‐3.Implants for surgery—Metallic materials—Wrought titanium 6 aluminum—4 vanadium alloy.Geneva:International Organization for Standardization;1996.
13. Boyer R · 1998
14. ISO5832‐12.Implants for surgery—Metallic materials—Wrought cobalt–chromium–molybdenum alloy Geneva:International Organization for Standardization;1996.
15. Kerlins V · 1992 · 16
16. 10.1002/jbm.82018090810.1002/jbm.820180908 ↗
17. 10.1002/jbm.82018050410.1002/jbm.820180504 ↗
18. 10.1002/jbm.82024110610.1002/jbm.820241106 ↗
19. 10.1002/jbm.82022040410.1002/jbm.820220404 ↗
20. 10.1002/jbm.82024050610.1002/jbm.820240506 ↗
21. Welsch G · 1994 · 1051
22. ISO7206 parts 3 (1988) and 7 (1993).Implants for surgery. Partial and total hip joint prostheses—Determination of endurance properties of stemmed femoral components without application of torsion.Geneva:International Organization for Standardization.
23. 10.1016/S0021-9290(98)00190-010.1016/S0021-9290(98)00190-0 ↗
24. 10.1002/jbm.82029071310.1002/jbm.820290713 ↗