journal article·2018-07Open access

In vitroandin vivodegradation of microfiber bioresorbable coronary scaffold

Chi‐Hung Huang, Sheng‐Yang Lee, Sonida Horng, Louis‐Georges Guy, Ting‐Bin Yu

Abstract

Abstract The degradation of Mirage Bioresorbable Microfiber Scaffold was evaluatedin vitroandin vivo. The degradation in polymer molecular weight (MW), strut morphology, and integrity was accessed using gel permeation chromatography (GPC), X‐ray micro‐computed tomography (micro‐CT) evaluation. To simulate the physiological degradationin vitro, scaffolds were deployed in silicone mock vessels connected to a peristaltic pumping system, which pumps 37°C phosphate‐buffered saline (PBS, pH 7.4) at a constant rate. At various time points (30D, 60D, 90D, 180D, 270D,and360D), the MW of microfibers decreased to 57.3, 49.8, 36.9, 13.9, 6.4, and 5.1% against the baseline. Thein vivodegradation study was performed by implanting scaffolds in internal thoracic arteries (ITAs) of mini‐swine. At the scheduled sacrifice time points (30D, 90D, 180D, 270D, 360D, and 540D), the implanted ITAs were excised for GPC analysis; the MW of the implanted scaffolds dropped to 58.5, 34.7, 24.8, 16.1, 12.9, and 7.1, respectively. Mass loss of scaffolds reached 72.4% at 540D of implantation. Two stages of hydrolysis were observed inin vitroand invivodegradation kinetics, and the statistical analysis suggested a positive correlation betweenin vivoandin vitrodegradation. After 6 months of incubation in animals, significant strut degradation was seen in the micro‐CT evaluation in all sections as strut fragments and separations. The micro‐CT results further confirmed that every sample at 720D had X‐ray transmission similar to surrounding tissue, thereby indicating full degradation within 2 years. © 2017 The Authors. Journal of Biomedical Materials Research Part B: Applied Biomaterials published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1842–1850, 2018.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Coronary Interventions and Diagnostics · Orthopaedic implants and arthroplasty · Cardiac Structural Anomalies and Repair

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Division of Cardiology, Department of Internal Medicine Cathay General Hospital Taipei Taiwan

School of Dentistry, College of Oral Medicine Taipei Medical University Taipei Taiwan

Dental Department of Taipei Medical University Wan‐Fang Hospital Taipei Taiwan

Accellab Inc. Boisbriand Quebec J7H 1N8 Canada

DuNing Inc. Tustin California 92780

References (39)

Show source-provided references
1. 10.1007/978-3-642-46381-5_910.1007/978-3-642-46381-5_9 ↗
2. 10.1161/01.CIR.78.3.55710.1161/01.CIR.78.3.557 ↗
3. 10.1161/01.CIR.78.5.112110.1161/01.CIR.78.5.1121 ↗
4. 10.1056/NEJM19940825331080110.1056/NEJM199408253310801 ↗
5. 10.1056/NEJM19940825331080210.1056/NEJM199408253310802 ↗
6. 10.2147/vhrm.2005.1.4.26310.2147/vhrm.2005.1.4.263 ↗
7. Novel drug‐eluting stents in the treatment of de novo coronary lesions
8. 10.1056/NEJMoa03507110.1056/NEJMoa035071 ↗
9. 10.1097/00019501-200409000-0000310.1097/00019501-200409000-00003 ↗
10. 10.1002/jbm.a.3205710.1002/jbm.a.32057 ↗
11. 10.2147/vhrm.2008.04.01.3110.2147/vhrm.2008.04.01.31 ↗
12. 10.1016/j.jcin.2011.11.01310.1016/j.jcin.2011.11.013 ↗
13. 10.1161/CIRCULATIONAHA.110.97160610.1161/CIRCULATIONAHA.110.971606 ↗
14. 10.1038/nrcardio.2016.15110.1038/nrcardio.2016.151 ↗
15. 10.1161/01.CIR.102.4.39910.1161/01.CIR.102.4.399 ↗
16. 10.1161/CIRCULATIONAHA.110.00090110.1161/CIRCULATIONAHA.110.000901 ↗
17. 10.1161/CIRCULATIONAHA.110.97077210.1161/CIRCULATIONAHA.110.970772 ↗
18. 10.4244/EIJY15M02_0110.4244/EIJY15M02_01 ↗
19. 10.1016/j.biomaterials.2005.09.00210.1016/j.biomaterials.2005.09.002 ↗
20. 10.4244/EIJV5IFA1010.4244/EIJV5IFA10 ↗
21. 10.1016/j.actbio.2014.07.00510.1016/j.actbio.2014.07.005 ↗
22. Short‐term safety and efficacy of the biodegradable iron stent in mini‐swine coronary arteries10.3760/cma.j.issn.0366-6999.20131120 ↗
23. 10.1016/S0735-1097(16)30233-910.1016/S0735-1097(16)30233-9 ↗
24. 10.1186/s12872-016-0207-510.1186/s12872-016-0207-5 ↗
25. 10.1093/eurheartj/ehr46610.1093/eurheartj/ehr466 ↗
26. 10.1016/j.jacc.2016.09.56610.1016/j.jacc.2016.09.566 ↗
27. 10.1016/j.jcin.2017.03.01510.1016/j.jcin.2017.03.015 ↗
28. 10.1114/1.157575610.1114/1.1575756 ↗
29. 10.1016/j.mri.2013.10.00910.1016/j.mri.2013.10.009 ↗
30. 10.1021/bm070313n10.1021/bm070313n ↗
31. 10.1002/app.1995.07057010910.1002/app.1995.070570109 ↗
32. 10.1002/polb.2034010.1002/polb.20340 ↗
33. 10.1586/14779072.2013.83920010.1586/14779072.2013.839200 ↗
34. 10.1016/j.jcin.2015.12.00410.1016/j.jcin.2015.12.004 ↗
35. 10.1179/174328008X27780310.1179/174328008X277803 ↗
36. Role of X‐ray microtomography in tissue engineering
37. 10.1016/j.jneumeth.2010.01.03210.1016/j.jneumeth.2010.01.032 ↗
38. 10.1016/0141-3910(96)00009-210.1016/0141-3910(96)00009-2 ↗
39. Review on hydrolytic degradation behavior of biodegradable polymers from controlled drug delivery system