journal article·2009-05Open access

Preparation, characterization, and evaluation of radiopaque hydrogel filaments for endovascular embolization

Michael J. Constant, Edward M. Keeley, Gregory M. Cruise

Abstract

Abstract Radiopaque hydrogel filaments were prepared, characterized, and evaluated for potential use as implants for endovascular embolization of vascular defects. Three hydrogel formulations were prepared by free radical polymerization: (i) poly(ethylene glycol) diacrylate with 2,4,6‐triiodophenyl penta‐4‐enoate (PEG‐I), (ii) poly(ethylene glycol) diacrylamide with barium sulfate (PEG‐B), and (iii) poly(propylene glycol) diacrylate with barium sulfate (PPG‐B). The PEG‐B and PPG‐B hydrogels exhibited radiopacity comparable with clinically used platinum coils, whereas the PEG‐I hydrogel did not. In the dry state, the average ultimate tensile strength and strain of the hydrogels ranged from 37 to 128 gf and 21% to 72%, respectively. The PEG‐B hydrogel had significantly higher tensile strength compared with the PEG‐I hydrogel. In the hydrated state, the average ultimate tensile strength and strain ranged from 5 to 15 gf and 7% to 30%, respectively. Statistically significant differences in tensile strength were not present when hydrated. Compared with poly(ethylene) after 4‐week implantation into the subcutaneous space of rabbits, the PEG‐I hydrogel elicited slightly more inflammation, whereas the PEG‐B and PPG‐B hydrogels elicited less inflammation. All three hydrogel formulations elicited less fibrous encapsulation than poly(ethylene). With further development, these materials have potential as embolization devices. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Intracranial Aneurysms: Treatment and Complications · Aortic Disease and Treatment Approaches · Aortic aneurysm repair treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. 10.1016/S0140-6736(05)67214-510.1016/S0140-6736(05)67214-5 ↗
2. 10.3171/jns.1999.91.2.028410.3171/jns.1999.91.2.0284 ↗
3. 10.1161/01.STR.0000073841.88563.E910.1161/01.STR.0000073841.88563.E9 ↗
4. 10.3171/foc.2005.18.2.210.3171/foc.2005.18.2.2 ↗
5. Angiographic and histologic analysis of experimental aneurysms embolized with platinum coils, Matrix, and HydroCoil
6. New expandable hydrogel‐platinum coil hybrid device for aneurysm embolization
7. Cerecyte coils in the treatment of intracranial aneurysms: a preliminary clinical study
8. 10.1161/01.STR.0000177532.94736.8510.1161/01.STR.0000177532.94736.85 ↗
9. 10.1161/01.STR.0000083394.33633.C210.1161/01.STR.0000083394.33633.C2 ↗
10. 10.3174/ajnr.A069710.3174/ajnr.A0697 ↗
11. MR‐angiography as a method for evaluating endovascular coiled cerebral aneurysms
12. 10.1002/jmri.2055510.1002/jmri.20555 ↗
13. 10.1021/bm005629910.1021/bm0056299 ↗
14. Healing response in elastase‐induced rabbit aneurysms after embolization with a new platinum coil system
15. 10.1097/00006123-199910000-0001310.1097/00006123-199910000-00013 ↗
16. 10.1243/09544119JEIM8810.1243/09544119JEIM88 ↗
17. 10.1016/j.biomaterials.2005.04.02010.1016/j.biomaterials.2005.04.020 ↗
18. 10.1016/j.biomaterials.2007.03.02510.1016/j.biomaterials.2007.03.025 ↗
19. 10.1002/jbm.a.3029310.1002/jbm.a.30293 ↗
20. 10.1021/bm700754m10.1021/bm700754m ↗
21. 10.1016/j.biomaterials.2007.06.03210.1016/j.biomaterials.2007.06.032 ↗
22. 10.3171/jns.2006.104.2.29010.3171/jns.2006.104.2.290 ↗
23. N‐Butyl cyanoacrylate embolization of cerebral arteriovenous malformations: results of a prospective, randomized, multi‐center trial
24. 10.1586/17434440.3.6.70510.1586/17434440.3.6.705 ↗
25. 10.1136/bmj.38981.652118.DE10.1136/bmj.38981.652118.DE ↗
26. 10.2214/AJR.06.132810.2214/AJR.06.1328 ↗