Critical comparison of two methods for the determination of nanomechanical properties of a material: Application to synthetic and natural biomaterials
Source abstract
Abstract
Abstract Two methods used for determining the elastic modulus (E) and hardness (H) of a material—the original version of the well‐known Oliver‐Pharr Method, OOPM, and a variant of it called the Modified Slopes Method, MSM—were critically compared. The nanoindentation test results, of indenter load‐versus‐indenter displacement, were recorded for six series of specimens, three of commercially‐available acrylic bone cements (Palacos® R and Cemex® XL) and three of bones (human, bovine, and mouse). In the first series, the specimens were prepared from Palacos® R cement mantles retrieved from cemented total hip joint replacements after 11 months, 11 years, and 21 years in vivo. In the second and third series, the specimens were fabricated from hand‐ and vacuum‐mixed dough of Cemex XL® cement, respectively. In the fourth, fifth, and sixth series, the specimens were prepared from fresh frozen cortical bone of human tibia, plexiform bone from fresh bovine tibia, and femora from inbred mice, respectively. It was found that, for a given material, the values of E or H computed using OOPM and MSM are not significantly different. However, the recommendation is that MSM is preferable because it is straightforward—only the nanoindentation measurements and values of constants that depend on the geometry of the indenter used are needed. In contrast, when the OOPM is used, there is a critical input (the indenter tip area function), whose computation is problematic. The article also includes a succinct discussion of factors that affect the values of material properties computed from nanoindentation measurements, such as the loading rate and the surface roughness of the test specimen. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Metal and Thin Film Mechanics · Diamond and Carbon-based Materials Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (29)
Show source-provided references
1. 10.1016/S0142-9612(97)00073-210.1016/S0142-9612(97)00073-2 ↗
2. 10.1016/j.biomaterials.2003.11.04710.1016/j.biomaterials.2003.11.047 ↗
3. EbensteinDM KingK PruittLA.A nanoindentation technique for measuring the mechanical properties of finger joint cartilage. Transactions of 29th Annual Meeting of the Society for Biomaterials Reno NV April 30–May 3 2003; p718.
4. 10.1016/S0142-9612(00)00297-010.1016/S0142-9612(00)00297-0 ↗
5. 10.1016/S0142-9612(03)00202-310.1016/S0142-9612(03)00202-3 ↗
6. 10.1016/j.biomaterials.2003.09.01410.1016/j.biomaterials.2003.09.014 ↗
7. PruittL Al‐MarashiL YoungE PetrieTA HetheringtonA GoldsteinP EbensteinD RiesM.Evaluation of mechanical properties of acrylic bone cement from hip arthroplasty revision surgery. Transactions of the 7th World Biomaterials Congress May 17–21 2004 Sydney Australia; p1468.
8. 10.1016/j.matlet.2003.09.02610.1016/j.matlet.2003.09.026 ↗
9. 10.1557/jmr.2004.19.1.15810.1557/jmr.2004.19.1.158 ↗
10. 10.1016/j.surfcoat.2004.03.03710.1016/j.surfcoat.2004.03.037 ↗
11. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments10.1557/JMR.1992.1564 ↗
12. 10.1016/j.actamat.2003.10.01310.1016/j.actamat.2003.10.013 ↗
13. 10.3139/146.02087010.3139/146.020870 ↗
14. 10.3139/146.03079310.3139/146.030793 ↗
15. American Society for Testing and Materials (ASTM) Standard D 5045–99.Standard test methods for plane‐strain fracture toughness and strain energy release rate of plastic materials. Annual Book of ASTM Standards 08.03 ASTM International West Conshohocken PA USA;2001. p347–355.
16. 10.1007/978-3-642-59762-610.1007/978-3-642-59762-6 ↗
17. FanZF SmithPA HarrisGF.Mechanical properties of OI type III human bone tissue measured by nanoindentation. Transactions of the 51st Annual Meeting of the Orthopaedic Research Society February 20–23 2005 Washington DC USA. p 0030.
18. 10.1359/JBMR.04050610.1359/JBMR.040506 ↗
19. 10.1097/01.BRS.0000128760.94173.9010.1097/01.BRS.0000128760.94173.90 ↗
20. 10.1557/jmr.2004.19.1.310.1557/jmr.2004.19.1.3 ↗
21. 10.1557/JMR.1990.012310.1557/JMR.1990.0123 ↗
22. 10.1007/978-0-387-22462-610.1007/978-0-387-22462-6 ↗
23. 10.1115/1.133073610.1115/1.1330736 ↗
24. 10.1088/0022-3727/31/19/00610.1088/0022-3727/31/19/006 ↗
25. 10.1002/jbm.a.3022610.1002/jbm.a.30226 ↗
26. 10.3109/1745367870914633810.3109/17453678709146338 ↗
27. TrieuHH PaxsonRD CarrollME BertJM.A comparative study of bone cement preparation using a new centrifugation mixing technique. Transactions of the 20th Annual Meeting of the Society for Biomaterials April 5–9 Boston MA USA. p 416.
28. 10.1016/S0142-9612(00)00363-X10.1016/S0142-9612(00)00363-X ↗
29. 10.1002/jbm.a.1002710.1002/jbm.a.10027 ↗