Sterilization of medical devices by ethylene oxide, determination of the dissipation of residues, and use of Green Fluorescent Protein as an indicator of process control
Source abstract
Abstract
Abstract Ethylene oxide (EO) is used to sterilize Oxygenator and Tubing applied to heart surgery. Residual levels of EO and its derivatives, ethylene chlorohydrin (ECH) and ethylene glycol (EG), may be hazardous to the patients. Therefore, it must be removed by the aeration process. This study aimed to estimate the minimum aeration time for these devices to attain safe limits for use (avoiding excessive aeration time) and to evaluate the Green Fluorescent Protein (GFP) as a biosensor capable of best indicating the distribution and penetration of EO gas throughout the sterilization chamber. Sterilization cycles of 2, 4, and 8 h were monitored by Bacillus atrophaeus ATCC 9372 as a biological indicator (BI) and by the GFP. Residual levels of EO, ECH, and EG were determined by gas chromatography (GC), and the residual dissipation was studied. Safe limits were reached right after the sterilization process for Oxygenator and after 204 h of aeration for Tubing. In the 2 h cycle, the GFP concentration decreased from 4.8 (±3.2)% to 7.5 (±2.5)%. For the 4 h cycle, the GFP concentration decreased from 17.4 (±3.0)% to 21.5 (±6.8)%, and in the 8 h cycle, it decreased from 22.5 (±3.2)% to 23.9 (±3.9)%. This finding showed the potentiality for GFP applications as an EO biosensor. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Medical Device Sterilization and Disinfection · 3D Printing in Biomedical Research · Protein purification and stability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (21)
Show source-provided references
1. Ethylene oxide sterilization of surgical sutures monitored by Bacillus subtilis
2. 10.1016/S0142-9612(03)00264-310.1016/S0142-9612(03)00264-3 ↗
3. 10.1002/jbm.b.1003610.1002/jbm.b.10036 ↗
4. Ethylene oxide sterilization of medical devices with special reference to the sporicidal activity and residual concentration of ethylene oxide and its secondary products
5. Measurement of ethylene oxide at a medical sterilization site
6. International Standards Organization.Sterilization of health care products—Requirements for validation and routine control—Industrial moist heat sterilization. ISO 11134. Geneva Switzerland;1994.
7. International Standards Organization.Medical devices—Validation and routine control of ethylene oxide sterilization. ISO 11135. Geneva Switzerland;1994.
8. International Standards Organization.Biological evaluation of medical devices part 7—Ethylene oxide sterilization residuals. ISO 10993‐7. Geneva Switzerland;1995.
9. Rutala WA · 1998
10. 10.1021/bp070090c10.1021/bp070090c ↗
11. 10.5897/AJB2004.000-201910.5897/AJB2004.000-2019 ↗
12. 10.1021/bp060217i10.1021/bp060217i ↗
13. Stability of recombinant green fluorescent protein (GFPuv) in glucose solutions at different concentrations and pH values
14. 10.1016/j.ijpharm.2006.12.04110.1016/j.ijpharm.2006.12.041 ↗
15. International Standards Organization.Cleanrooms and associated controlled environments—Part 1: Classification of air Cleanliness. ISO 14644‐1. Geneva Switzerland;1999.
16. 10.1002/jbm.b.3082510.1002/jbm.b.30825 ↗
17. Validation of sterilisation process with ethylene oxide
18. 10.1016/0142-9612(86)90108-010.1016/0142-9612(86)90108-0 ↗
19. 10.1002/jbm.104710.1002/jbm.1047 ↗
20. US Food and Drug Administration. Public Health Notification on PVC Devices Containing the Plasticizer DEHP. 2002. Available at:http://www.fda.gov/cdrh/safety/dehp.html.