Abstract Wounds often cannot be successfully closed by conventional means of closure such as sutures or staples. Our group developed the FiberSecure™ device to close soft tissue wounds reliably, surpassing native tissue strength. We closed cross‐fiber muscle incisions, to evaluate (1) four different configurations of FiberSecure™ for 30 days, then (2) the resulting preferred configuration for 180 days. The four treatment groups each placed 21,504 polyester (PET) 12‐μm fibers (cross‐sectional area 1% of muscle) traversing the incision, in the form of (A) Four large (No.7 suture) non‐textured bundles, (B) Eight small (No.2 suture) non‐textured, (C) Four large textured, or (D) Eight small textured. Four incisions were closed in the external oblique muscle of 16 Sinclair minipigs. At 30 days, specimens were removed for biomechanics, histology, and total collagen content. Group (B) was selected for 180‐day evaluations in the same wound model in eight animals, four closures each (n = 32), again with biomechanics and histology. In strength testing, every specimen tore through muscle remotely, while the repair region remained intact. Maximum forces were (A) 37.8 ± 3.9 N, (B) 37.1 ± 4.7 N, (C) 39.0 ± 5.3 N, and (D) 32.4 ± 3.4 N at 30 days, and 37.2 ± 11.3 N at 180 days (mean ± SEM). No significant difference was observed among the groups or time points (p > 0.05). © 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2011.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Surgical Sutures and Adhesives · Reconstructive Surgery and Microvascular Techniques · Wound Healing and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (24)

Show source-provided references
1. 10.1016/S0002-9610(02)00935-210.1016/S0002-9610(02)00935-2 ↗
2. 10.1080/11024159975000807110.1080/110241599750008071 ↗
3. 10.1046/j.1365-2168.2002.02258.x10.1046/j.1365-2168.2002.02258.x ↗
4. 10.1016/S0029-7844(02)02239-110.1016/S0029-7844(02)02239-1 ↗
5. 10.1053/beog.2001.025610.1053/beog.2001.0256 ↗
6. 10.1016/0002-9610(84)90471-910.1016/0002-9610(84)90471-9 ↗
7. Annular versus subvalvular approaches to acute ischemic mitral regurgitation
8. 10.1097/00003081-200206000-0002110.1097/00003081-200206000-00021 ↗
9. 10.1080/11024150175021522110.1080/110241501750215221 ↗
10. 10.1111/j.1749-6632.1968.tb20278.x10.1111/j.1749-6632.1968.tb20278.x ↗
11. 10.3109/1073119730911886410.3109/10731197309118864 ↗
12. 10.1097/00002480-199703000-0014210.1097/00002480-199703000-00142 ↗
13. 10.1097/01.MAT.0000065369.46216.9C10.1097/01.MAT.0000065369.46216.9C ↗
14. 10.1097/00002480-200201000-0001310.1097/00002480-200201000-00013 ↗
15. Fiber technology for reliable repair of skeletal muscle10.1002/jbm.b.31280 ↗
16. 10.1016/0076-6879(82)82074-010.1016/0076-6879(82)82074-0 ↗
17. 10.1080/11024150044708310.1080/110241500447083 ↗
18. 10.1001/archsurg.134.11.126010.1001/archsurg.134.11.1260 ↗
19. A comparison of polypropylene mesh and expanded polytetrafluoroethylene patch for the repair of contaminated abdominal wall defects—An experimental study
20. 10.1097/00000658-200010000-0001410.1097/00000658-200010000-00014 ↗
21. The relative importance of Vicryl and Prolene sutures to the strength of healing abdominal wounds
22. 10.1097/01.MAT.0000065369.46216.9C10.1097/01.MAT.0000065369.46216.9C ↗
23. 10.1111/j.1525-1594.2005.29108.x10.1111/j.1525-1594.2005.29108.x ↗
24. Retention mesh: An alternative to retention sutures