Tribology of flexible and sliding spinal implants: Development of experimental and numerical models
Source abstract
Abstract
Abstract New fusionless devices are being developed to get over the limits of actual spinal surgical treatment, based on arthrodesis. However, due to their recentness, no standards exist to test and validate those devices, especially concerning the wear. A new tribological first approach to the definition of an in vitro wear protocol to study wear of flexible and sliding spinal devices is presented in this article, and was applied to a new concept. A simplified synthetic spine portion (polyethylene) was developed to reproduce a simple supra‐physiological spinal flexion (10° between two vertebrae). The device studied with this protocol was tested in wet environment until 1 million cycles (Mc). We obtained an encouraging estimated wear volume of same order of magnitude compared to similar devices. An associated finite element (FE) numerical model has permitted to access contact information and study the effect of misalignment of one screw. First results could point out how to improve the design and suggest that a vertical misalignment of a screw (under or over‐screwing) has more impact than a horizontal one. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 104–111, 2018.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Spine and Intervertebral Disc Pathology · Nerve Injury and Rehabilitation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Aix‐Marseille Université, CNRS, ISM UMR 7287, 13288 Marseille cedex 09 France
APHM, Hôpital Sainte‐Marguerite, Institute for Locomotion 13009 Marseille France
Funding
Association Française contre les Myopathies (AFMTéléthon)
References (26)
Show source-provided references
1. A new technic for segmental spinal osteosynthesis using the posterior approach
2. 10.3928/01477447-20140728-0810.3928/01477447-20140728-08 ↗
3. 10.3171/foc.2007.22.1.1110.3171/foc.2007.22.1.11 ↗
4. Biomechanical evaluation of pedicle screw‐based dynamic stabilization devices for the lumbar spine: A systematic review10.1016/S1935-9810(08)70035-5 ↗
5. Shilla growing rods in a caprine animal model: A pilot study10.1007/s11999-009-1028-y ↗
6. 10.1007/s11999-011-1783-410.1007/s11999-011-1783-4 ↗
7. A preliminary study on a novel growth guidance rod system for early‐onset scoliosis in a sheep model10.1097/BRS.0000000000000819 ↗
8. 10.1097/BRS.000000000000066010.1097/BRS.0000000000000660 ↗
9. 10.1016/j.spinee.2015.11.04010.1016/j.spinee.2015.11.040 ↗
10. 10.1097/BRS.0b013e31822a982f10.1097/BRS.0b013e31822a982f ↗
11. 10.1097/BRS.0b013e3181e21b5010.1097/BRS.0b013e3181e21b50 ↗
12. The influence of fixation rigidity on intervertebral joints. An experimental comparison between a rigid and a flexible system
13. Standard test methods for spinal implant constructs in a vertebrectomy model
14. Implants for surgery ‐ Mechanical testing of implantable spinal devices ‐ Fatigue test method for spinal implant assemblies using an anterior support
15. Implants for surgery ‐ Wear of total intervertebral spinal disc prostheses
16. Standard guide for functional, kinematic, and wear assessment of total disc prostheses
17. 10.1097/BRS.0b013e31829991e010.1097/BRS.0b013e31829991e0 ↗
18. Kapandji IA. · 1974
19. 10.1016/j.biomaterials.2007.07.01310.1016/j.biomaterials.2007.07.013 ↗
20. Flexible non‐fusion scoliosis correction systems reduce intervertebral rotation less than rigid implants and allow growth of the spine: a finite element analysis of different features of orthobiomTM10.1007/s00586-007-0480-1 ↗
21. Luque‐Trolley growing‐rod construct in the surgical treatment of early onset idiopathic scoliosis—a long term follow‐up study10.1016/S1529-9430(03)00246-8 ↗
22. 10.1016/S0021-9290(01)00215-910.1016/S0021-9290(01)00215-9 ↗
23. Comparative evaluation of metal and polymer ball bearings10.1016/j.wear.2013.01.057 ↗
24. Pedicle screw fixation study in immature porcine spines to improve pullout resistance during animal testing10.1371/journal.pone.0127463 ↗
25. 10.1016/j.wear.2013.03.05210.1016/j.wear.2013.03.052 ↗
26. 10.1016/j.biomaterials.2009.09.06410.1016/j.biomaterials.2009.09.064 ↗