journal article·2013-09

Polycaprolactone coating with varying thicknesses for controlled corrosion of magnesium

Min Park, Ji Eun Lee, Chun Gwon Park, Seung Ho Lee, Hyun Kwang Seok, Young Bin Choy

Publisher page

Abstract

Controlled corrosion of magnesium is critical for its clinical application to orthopedic devices. For this purpose, we coated the surface of Mg with a biodegradable polymer, polycaprolactone (PCL) and attempted to control the Mg corrosion with varied coating thicknesses in a reproducible manner. As we increased the coating thickness from 0 to 13.31 ± 0.36 μm, the volume of hydrogen gas and amount of Mg ions, the indicators of Mg corrosion, decreased by almost half from 0.57 mL/cm2/day and 0.55 mg/day to 0.20 mL/cm2/day and 0.26 mg/day, respectively. However, the elemental compositions on the surface revealed possible detachment of polymer coating and rapid water absorption at the early stage of corrosion for all coating thicknesses. Therefore, the lessons learned from this study suggest pre-treatment of the Mg surface for better polymer–metal adhesion, as well as preparation of the coating with lowered porosity as a stronger water-permeation barrier, to eventually allow precise control on Mg corrosion.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Hydrogen Storage and Materials · Aluminum Alloys Composites Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. Staiger, MP, Pietak, AM, Huadmai, J, Dias, G, “Magnesium and its alloys as orthopedic biomaterials: a review.” Biomaterials, 27 (9) 1728–1734 (2006)10.1016/j.biomaterials.2005.10.003 ↗
2. Niinomi, M, “Recent Metallic Materials for Biomedical Applications.” Metall. Mater. Trans. A, 33 (3) 477–486 (2002)10.1007/s11661-002-0109-2 ↗
3. Ambrose, CG, Clanton, TO, “Bioabsorbable Implants: Review of Clinical Experience in Orthopedic Surgery.” Ann. Biomed. Eng., 32 (1) 171–177 (2004)10.1023/B:ABME.0000007802.59936.fc ↗
4. Middleton, JC, Tipton, AJ, “Synthetic Biodegradable Polymers as Orthopedic Devices.” Biomaterials, 21 (23) 2335–2346 (2000)10.1016/S0142-9612(00)00101-0 ↗
5. Shikinami, Y, Okuno, M, “Bioresorbable Devices Made of Forged Composites of Hydroxyapatite (HA) Particles and Poly-lactide (PLLA). Part II: Practical Properties of Miniscrews and Miniplates.” Biomaterials, 22 (23) 3197–3211 (2001)10.1016/S0142-9612(01)00072-2 ↗
6. Zhang, S, Zhang, X, Zhao, C, Li, J, Song, Y, Xie, C, Tao, H, Zhang, Y, He, Y, Jiang, Y, “Research on an Mg–Zn Alloy as a Degradable Biomaterial.” Acta Biomater., 6 (2) 626–640 (2010)10.1016/j.actbio.2009.06.028 ↗
7. Zhang, E, Xu, L, Yu, G, Pan, F, Yang, K, “In Vivo Evaluation of Biodegradable Magnesium Alloy Bone Implant in the First 6 Months Implantation.” J. Biomed. Mater. Res. A, 90 (3) 882–893 (2009)10.1002/jbm.a.32132 ↗
8. Reifenrath, J, Bormann, D, Meyer-Lindenberg, A, “Magnesium Alloys as Promising Degradable Implant Materials in Orthopaedic Research.” In: Czerwinski, F (ed.) Magnesium Alloys—Corrosion and Surface Treatments. InTech (2011). Available from http://www.intechopen.com/books/magnesium-alloys-corrosion-and-surface-treatments/magnesium-alloys-as-promising-degradable-implant-materials-in-orthopaedic-research10.5772/14143 ↗
9. Gu, XN, Zheng, YF, “A Review on Magnesium Alloys as Biodegradable Materials.” Front. Mater. Sci. China, 4 (2) 111–115 (2010)10.1007/s11706-010-0024-1 ↗
10. Wang, H, Shi, Z, “In Vitro Biodegradation Behavior of Magnesium and Magnesium Alloy.” J. Biomed. Mater. Res. Part B: Appl. Biomater., 98 (2) 203–209 (2011)10.1002/jbm.b.31769 ↗
11. Yamamoto, A, Hiromoto, S, “Effect of Inorganic Salts, Amino Acids and Proteins on the Degradation of Pure Magnesium In Vitro.” Mater. Sci. Eng. C, 29 (5) 1559–1568 (2009)10.1016/j.msec.2008.12.015 ↗
12. Saris, NEL, Mervaala, E, Karppanen, H, Khawaja, JA, Lewenstam, A, “Magnesium: An Update on Physiological, Clinical and Analytical Aspects.” Clin. Chim. Acta, 294 (1–2) 1–26 (2000)10.1016/S0009-8981(99)00258-2 ↗
13. Vormann, J, “Magnesium: Nutrition and Metabolism.” Mol. Aspects Med., 24 (1–3) 27–37 (2003)10.1016/S0098-2997(02)00089-4 ↗
14. Witte, F, Kaese, V, Haferkamp, H, Switzer, E, Meyer-Lindenberg, A, Wirth, C, Windhagen, H, “In Vivo Corrosion of Four Magnesium Alloys and the Associated Bone Response.” Biomaterials, 26 (17) 3557–3563 (2005)10.1016/j.biomaterials.2004.09.049 ↗
15. Song, G, “Control of Biodegradation of Biocompatable Magnesium Alloys.” Corros. Sci., 49 (4) 1696–1701 (2007)10.1016/j.corsci.2007.01.001 ↗
16. Fan, Y, Wu, G, Zhai, C, “Influence of Cerium on the Microstructure, Mechanical Properties and Corrosion Resistance of Magnesium Alloy.” Mater. Sci. Eng. A, 433 (1) 208–215 (2006)10.1016/j.msea.2006.06.109 ↗
17. Song, G, St John, D, “The Effect of Zirconium Grain Refinement on the Corrosion Behaviour of Magnesium Rare Earth Alloy MEZ.” J. Light Met., 2 (1) 1–16 (2002)10.1016/S1471-5317(02)00008-1 ↗
18. Gu, X, Zheng, Y, Lan, Q, Cheng, Y, Zhang, Z, Xi, T, Zhang, D, “Surface Modification of an Mg-1Ca Alloy to Slow Down its Biocorrosion by Chitosan.” Biomed. Mater., 4 044109 (2009)10.1088/1748-6041/4/4/044109 ↗
19. Ng, W, Wong, M, Cheng, F, “Stearic Acid Coating on Magnesium for Enhancing Corrosion Resistance in Hanks’ Solution.” Surf. Coat. Technol., 204 (11) 1823–1830 (2010)10.1016/j.surfcoat.2009.11.024 ↗
20. Li, J, Cao, P, Zhang, X, Zhang, S, He, Y, “In Vitro Degradation and Cell Attachment of a PLGA Coated Biodegradable Mg-6Zn Based Alloy.” J. Mater. Sci., 45 6038–6045 (2010)10.1007/s10853-010-4688-9 ↗
21. Chen, Y, Song, Y, Zhang, S, Li, J, Zhao, C, Zhang, X, “Interaction Between a High Purity Magnesium Surface and PCL and PLA Coatings During Dynamic Degradation.” Biomed. Mater., 6 025005 (2011)10.1088/1748-6041/6/2/025005 ↗
22. Gray, J, Luan, B, “Protective Coatings on Magnesium and Its Alloys: A Critical Review.” J. Alloy. Compd., 336 (1–2) 88–113 (2002)10.1016/S0925-8388(01)01899-0 ↗
23. Scriven, L, Physics and Applications of Dip Coating and Spin Coating. Cambridge University Press, Cambridge, 1988
24. Lee, JY, Han, G, Kim, YC, Byun, JY, Jang, J, Seok, HK, Yang, SJ, “Effects of Impurities on the Biodegradation Behavior of Pure Magnesium.” Metal. Mater. Int., 15 (6) 955–961 (2009)10.1007/s12540-009-0955-1 ↗
25. Wong, HM, Yeung, KWK, Lam, KO, Tam, V, Chu, PK, Luk, KDK, Cheung, K, “A Biodegradable Polymer-Based Coating to Control the Performance of Magnesium Alloy Orthopaedic Implants.” Biomaterials, 31 (8) 2084–2096 (2010)10.1016/j.biomaterials.2009.11.111 ↗
26. Kirkland, N, Lespagnol, J, Birbilis, N, Staiger, M, “A Survey of Bio-corrosion Rates of Magnesium Alloys.” Corros. Sci., 52 (2) 287–291 (2010)10.1016/j.corsci.2009.09.033 ↗
27. Gray-Munro, JE, Seguin, C, Strong, M, “Influence of Surface Modification on the In Vitro Corrosion Rate of Magnesium Alloy AZ31.” J. Biomed. Mater. Res. Part A, 91 (1) 221–230 (2009)10.1002/jbm.a.32205 ↗
28. Tan, C, Blackwood, D, “Corrosion Protection by Multilayered Conducting Polymer Coatings.” Corros. Sci., 45 (3) 545–557 (2003)10.1016/S0010-938X(02)00144-0 ↗
29. Bautista, A, “Filiform Corrosion in Polymer-Coated Metals.” Prog. Org. Coat., 28 (1) 49–58 (1996)10.1016/0300-9440(95)00555-2 ↗
30. Cha, Y, Pitt, C, “The Biodegradability of Polyester Blends.” Biomaterials, 11 (2) 108–112 (1990)10.1016/0142-9612(90)90124-9 ↗
31. Yang, J, Cui, F, Lee, IS, “Surface Modifications of Magnesium Alloys for Biomedical Applications.” Ann. Biomed. Eng., 39 1857–1871 (2011)10.1007/s10439-011-0300-y ↗