Show source-provided references
2. Assessment of operability of patients with pulmonary arterial hypertension associated with congenital heart disease
10.1253/circj.CJ-13-1263 ↗6. Interventional catheterization performed in the early postoperative period after congenital heart surgery in children
10.1016/j.jacc.2003.10.051 ↗7. Bifurcating stents in the pulmonary arteries: a novel technique to relieve bilateral branch pulmonary artery obstruction
10.1002/ccd.25956 ↗8. Cost-effectiveness analysis of stents, balloon angioplasty, and surgery for the treatment of branch pulmonary artery stenosis
10.1007/s002469900195 ↗10. Redilation of endovascular stents in congenital heart disease: factors implicated in the development of restenosis and neointimal proliferation
10.1016/S0735-1097(01)01406-1 ↗12. Pulmonary artery stenting
13. First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby
10.1002/ccd.20520 ↗19. Long-term in vivo corrosion behavior, biocompatibility and bioresorption mechanism of a bioresorbable nitrided iron scaffold
10.1016/j.actbio.2017.03.020 ↗21. Materials and manufacturing technologies available for production of a pediatric bioabsorbable stent
10.1155/2013/137985 ↗23. A randomized trial comparing the NeoVas Sirolimus-Eluting bioresorbable scaffold and metallic Everolimus-Eluting stents
25. Maximal expansion capacity with current DES platforms: a critical factor for stent selection in the treatment of left main bifurcations?
10.4244/EIJV8I11A200 ↗27. Establishment of coverage-mass equation to quantify the corrosion inhomogeneity and examination of medium effects on iron corrosion
10.1093/rb/rbad007 ↗28. Long-term safety and absorption assessment of a novel bioresorbable nitrided iron scaffold in porcine coronary artery
34. Risk factors for coronary Drug-Eluting stent thrombosis: influence of procedural, patient, lesion, and stent related factors and dual antiplatelet therapy
10.1155/2013/748736 ↗35. Balloon expandable stents for coarctation of the aorta: review of current status and technical considerations
36. Intracoronary optical coherence tomography and histology at 1 month and 2, 3, and 4 years after implantation of Everolimus-Eluting bioresorbable vascular scaffolds in a porcine coronary artery model: an attempt to decipher the human optical coherence tomography images in the ABSORB trial
10.1161/CIRCULATIONAHA.109.921528 ↗37. Preclinical evaluation of the degradation kinetics of third-generation resorbable magnesium scaffolds
10.4244/EIJ-D-22-00718 ↗39. Effects of serum proteins on corrosion rates and product bioabsorbability of biodegradable metals
10.1093/rb/rbad112 ↗43. Initial status and 3-month results relating to the use of biodegradable nitride iron stents in children and the evaluation of right ventricular function
10.3389/fcvm.2022.914370 ↗45. Biaxial stretching of polytetrafluoroethylene in industrial scale to fabricate medical ePTFE membrane with node-fibril microstructure
10.1093/rb/rbad056 ↗46. Research and clinical translation of trilayer stent-graft of expanded polytetrafluoroethylene for interventional treatment of aortic dissection
10.1093/rb/rbac049 ↗47. Long-term efficacy of biodegradable metal-polymer composite stents after the first and the second implantations into porcine coronary arteries
10.1021/acsami.0c00971 ↗