Behavior and Modeling of Confined High-Strength Concrete
Source abstract
Abstract
This paper presents a study on the behavior and modeling of the stress-strain behavior of confined high-strength concrete (HSC) without silica fume. The behavior of actively confined HSC is first examined, and a unified active-confinement model applicable to both HSC and normal-strength concrete (NSC) is then proposed based on a large test database assembled from the existing literature. An experimental study on fiber-reinforced polymer (FRP)-confined HSC is next presented and interpreted to examine its behavior, forming the basis for the subsequent modeling work. It is eventually shown that a recent analysis-oriented model developed by the writers’ group for NSC also provides close predictions for FRP-confined HSC. While the work is primarily concerned with HSC without silica fume, the effect of incorporating silica fume into HSC on the behavior of confined HSC is also given appropriate attention. The presence of silica fume in HSC is shown to reduce the effectiveness of confinement in term of strain capacity.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Ph.D. Student, Dept. of Civil and Structural Engineering, The Hong Kong Polytechnic Univ., Hong Kong, China.
Chair Professor of Structural Engineering, Dept. of Civil and Structural Engineering, The Hong Kong Polytechnic Univ., Hong Kong, China (corresponding author).
Research Fellow, Dept. of Civil and Structural Engineering, The Hong Kong Polytechnic Univ., Hong Kong, China.
References (36)
Show source-provided references
1. 10.1016/j.compositesb.2006.06.02110.1016/j.compositesb.2006.06.021 ↗
2. American Concrete Institute (ACI). (2008). “Building code requirements for structural concrete (318M-08) and commentary.” ACI 318M-08 Detroit.
3. High-strength concrete subjected to triaxial compression
4. ASTM. (2000). “Standard test method for tensile properties of polymer matrix composite materials.” D3039 West Conshohocken Pa.
5. Stress-strain relationship of confined and unconfined concrete
6. Total strain theory and path-dependence of concrete10.1061/JMCEA3.0002657 ↗
7. 10.1016/j.conbuildmat.2004.05.01210.1016/j.conbuildmat.2004.05.012 ↗
8. 10.1016/j.engstruct.2005.03.00210.1016/j.engstruct.2005.03.002 ↗
9. 10.1061/(ASCE)0899-1561(2001)13:3(209)10.1061/(ASCE)0899-1561(2001)13:3(209) ↗
10. Chun S. S. and Park H. C. (2002). “Load carrying capacity and ductility of RC columns confined by carbon fiber reinforced polymer.” Proc. Third Int. Conf. on Composites in Infrastructure Omnipress Madison Wis. 1–12.
11. Confinement model for axially loaded concrete confined by circular fiber-reinforced polymer tubes
12. Behavior and modeling of concrete subject to variable confining pressure
13. Holland T. C. (2005). “Silica fume user’s manual.” Rep. No. FHWA-IF-05-016 DOT Washington D.C.
14. 10.1533/978184569489010.1533/9781845694890 ↗
15. Experimental study of plain concrete under triaxial stress
16. 10.1016/j.engstruct.2007.01.01010.1016/j.engstruct.2007.01.010 ↗
17. 10.1061/JSDEAG.000295710.1061/JSDEAG.0002957 ↗
18. 10.1061/(ASCE)0733-9445(2002)128:5(612)10.1061/(ASCE)0733-9445(2002)128:5(612) ↗
19. 10.1016/S0950-0618(03)00045-X10.1016/S0950-0618(03)00045-X ↗
20. 10.1016/S0008-8846(97)00269-X10.1016/S0008-8846(97)00269-X ↗
21. 10.1016/j.engstruct.2005.11.00610.1016/j.engstruct.2005.11.006 ↗
22. 10.1016/j.cemconres.2006.05.02110.1016/j.cemconres.2006.05.021 ↗
23. Influence of concrete strength on confinement effectiveness of fiber-reinforced polymer circular jackets
24. 10.1061/(ASCE)0733-9445(1988)114:8(1804)10.1061/(ASCE)0733-9445(1988)114:8(1804) ↗
25. 10.1061/(ASCE)1090-0268(2004)8:4(332)10.1061/(ASCE)1090-0268(2004)8:4(332) ↗
26. 10.1002/(SICI)1099-1484(199707)2:3<237::AID-CFM32>3.0.CO;2-210.1002/(SICI)1099-1484(199707)2:3<237::AID-CFM32>3.0.CO;2-2 ↗
27. 10.1016/0008-8846(73)90096-310.1016/0008-8846(73)90096-3 ↗
28. Ultimate strength of confined very high-strength concrete
29. 10.1061/(ASCE)1090-0268(1999)3:3(143)10.1061/(ASCE)1090-0268(1999)3:3(143) ↗
30. Tan K. H. and Sun X. (2004). “Failure criteria of concrete under triaxial compression.” Proc. Int. Symp. on Confined Concrete (CD-ROM) American Concrete Institute Farmington Hills Mich.
31. Teng J. G. · 2002
32. 10.1061/(ASCE)1090-0268(2007)11:2(201)10.1061/(ASCE)1090-0268(2007)11:2(201) ↗
33. 10.1061/(ASCE)CC.1943-5614.000001210.1061/(ASCE)CC.1943-5614.0000012 ↗
34. 10.1061/(ASCE)0733-9445(2004)130:11(1713)10.1061/(ASCE)0733-9445(2004)130:11(1713) ↗
35. 10.1061/(ASCE)0899-1561(1996)8:2(70)10.1061/(ASCE)0899-1561(1996)8:2(70) ↗
36. Mechanical properties of three high-strength concretes containing silica fume