journal article·2012-10

FRP-Masonry Debonding: Numerical and Experimental Study of the Role of Mortar Joints

Christian Carloni, Kolluru V. Subramaniam

Publisher page

Abstract

Fiber-reinforced polymers (FRP) composites are used as supplementary reinforcement to increase the in-plane shear capacity or to provide out-of-plane load-carrying capability of masonry walls and to modify the collapse mechanism in arches and vaults. In these applications, the efficiency of load transfer is limited by the debonding of FRP from the masonry substrate. In this paper, the debonding mechanism of FRP-masonry is experimentally studied. Experimental procedures and test specimens are designed to investigate the progressive debonding of FRP from brick and mortar substrates and relate it to the response obtained from the FRP-masonry interface. Surface displacements during debonding are obtained using digital image correlation. A one-dimensional numerical model is developed for predicting the fracture behavior along the FRP-masonry interface using the cohesive fracture parameters from the brick and mortar interfaces obtained from the computed strains.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Associate Professor, Dept. of Architecture, Univ. of Hartford, Hartford, CT (corresponding author).

Professor, Dept. of Civil Engineering, Indian Institute of Technology, Hyderabad, India.

References (25)

Show source-provided references
1. 10.1016/j.conbuildmat.2005.06.04010.1016/j.conbuildmat.2005.06.040 ↗
2. ASTM C270. (2010). “Standard specification for mortar for unit masonry.” ASTM International West Conshohocken PA.
3. ASTM C39/C39M. (2011). “Standard test method for compressive strength of cylindrical concrete specimens.” ASTM International West Conshohocken PA.
4. 10.1061/(ASCE)0733-9399(2006)132:9(914)10.1061/(ASCE)0733-9399(2006)132:9(914) ↗
5. 10.1061/(ASCE)0733-9399(2007)133:1(58)10.1061/(ASCE)0733-9399(2007)133:1(58) ↗
6. 10.1016/j.compstruct.2009.09.02910.1016/j.compstruct.2009.09.029 ↗
7. 10.1260/13694330978986789010.1260/136943309789867890 ↗
8. 10.1016/j.compstruct.2010.05.02410.1016/j.compstruct.2010.05.024 ↗
9. Casareto M. Olivieri A. Romelli A. and Lagomarsino S. (2003). “Bond behavior of FRP laminates adhered to masonry.” Proc. International Conf. Advancing with Composites Plast 2003 Crivelli-Visconti I. ed. Milan Italy.
10. 10.1016/j.compstruct.2010.03.01410.1016/j.compstruct.2010.03.014 ↗
11. 10.2749/10168661079355758210.2749/101686610793557582 ↗
12. 10.1061/(ASCE)CC.1943-5614.000017010.1061/(ASCE)CC.1943-5614.0000170 ↗
13. 10.1016/j.engstruct.2005.01.01410.1016/j.engstruct.2005.01.014 ↗
14. 10.1016/j.compositesb.2006.07.01910.1016/j.compositesb.2006.07.019 ↗
15. 10.1061/(ASCE)1090-0268(2008)12:6(643)10.1061/(ASCE)1090-0268(2008)12:6(643) ↗
16. 10.1016/j.conbuildmat.2011.03.03010.1016/j.conbuildmat.2011.03.030 ↗
17. 10.1061/(ASCE)1090-0268(2004)8:5(434)10.1061/(ASCE)1090-0268(2004)8:5(434) ↗
18. 10.1016/j.engfracmech.2006.09.00210.1016/j.engfracmech.2006.09.002 ↗
19. 10.1111/j.1475-1305.2008.00481.x10.1111/j.1475-1305.2008.00481.x ↗
20. 10.1520/CCA10467J10.1520/CCA10467J ↗
21. 10.1016/0262-8856(83)90064-110.1016/0262-8856(83)90064-1 ↗
22. 10.1016/S0143-7496(97)00018-310.1016/S0143-7496(97)00018-3 ↗
23. 10.1061/(ASCE)1090-0268(2004)8:1(79)10.1061/(ASCE)1090-0268(2004)8:1(79) ↗
24. 10.1016/j.conbuildmat.2007.09.00710.1016/j.conbuildmat.2007.09.007 ↗
25. 10.1260/13694330677882756510.1260/136943306778827565 ↗