Near-Surface-Mounted Composite System for Repair and Strengthening of Reinforced Concrete Columns Subjected to Axial Load and Biaxial Bending
Source abstract
Abstract
This paper aims to examine the effectiveness of near-surface-mounted (NSM) glass fiber-reinforced polymer (GFRP) composite rebars in combination with external confinement with carbon fiber-reinforced polymer (CFRP) composite sheets to repair and strengthen reinforced concrete (RC) columns exposed to axial load and biaxial bending. Nine columns with a square cross section of 150×150 mm were constructed and tested under biaxial eccentric loading with equal eccentricity along each principal axis. Test parameters included load eccentricity, concrete grade, and level of the CFRP confinement used in combination with the NSM-GFRP reinforcement. The effectiveness of the NSM-GFRP reinforcement was greatly affected by the CFRP-confinement level and the load eccentricity. For columns with a high level of CFRP confinement, the gain in the load capacity attributable to the NSM-GFRP reinforcement was higher at a lower eccentricity. For columns with a low level of CFRP confinement, the gain in the load capacity attributable to the NSM-GFRP reinforcement was higher at a higher eccentricity. The enhancement in the load capacity was more pronounced in the columns with a lower concrete grade. An analytical model for predicting the load capacity of RC columns strengthened with NSM-GFRP rebars in combination with CFRP confinement under axial load and biaxial bending is introduced. The model accounts for the nonlinear behavior of materials and the change in geometry under biaxial eccentric loading. The model accuracy is demonstrated by comparing the model predictions with the experimental results.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Associate Professor, UAE-Univ., Al-Ain, Abu Dhabi, P.O. Box 17555, UAE (corresponding author).
Professor, UAE-Univ., Al-Ain, Abu Dhabi, P.O. Box 17555, UAE.
References (33)
Show source-provided references
1. American Concrete Institute (ACI). (2005). “Building code requirements for structural concrete.” ACI 318-05 Farmington Hills MI.
2. American Concrete Institute (ACI). (2008a). “Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures.” ACI 440.2R Farmington Hills MI.
3. American Concrete Institute (ACI). (2008b). “Self-compacting concrete manual for concrete practice.” ACI 237R Farmington Hills MI.
4. Balaguru P. · 2009
5. 10.1002/978047012142910.1002/9780470121429 ↗
6. 10.1016/j.conbuildmat.2005.01.03010.1016/j.conbuildmat.2005.01.030 ↗
7. 10.1016/j.cemconcomp.2004.07.00410.1016/j.cemconcomp.2004.07.004 ↗
8. Strengthening of reinforced concrete columns with near-surface-mounted FRP or stainless steel
9. Performance of fiber-reinforced polymer-wrapped reinforced concrete columns under combined axial-flexural loading
10. 10.1061/(ASCE)1090-0268(2009)13:2(113)10.1061/(ASCE)1090-0268(2009)13:2(113) ↗
11. Near-surface-mounted fiber-reinforced polymer reinforcements for flexural strengthening of concrete structures
12. 10.1061/(ASCE)1090-0268(2009)13:1(13)10.1061/(ASCE)1090-0268(2009)13:1(13) ↗
13. 10.1617/s11527-010-9628-210.1617/s11527-010-9628-2 ↗
14. 10.1016/j.matdes.2009.12.00410.1016/j.matdes.2009.12.004 ↗
15. European Federation for Specialist Construction Chemicals and Concrete Systems (EFNARC) · 2005
16. Seismic upgrade with carbon fiber-reinforced polymer of columns containing lap-spliced reinforcing bars
17. 10.1016/j.compstruct.2005.01.01810.1016/j.compstruct.2005.01.018 ↗
18. Concrete stress distribution in ultimate strength design
19. 10.1533/978184569489010.1533/9781845694890 ↗
20. Jiang T. and Teng J. (2009). “Slender FRP-confined circular RC columns.” Proc. 9th Int. Symp. on Fiber-Reinforced Polymer Reinforcement for Concrete Structures (FRPRCS-9) ICE Melbourne Australia.
21. 10.1016/S0950-0618(03)00045-X10.1016/S0950-0618(03)00045-X ↗
22. 10.1061/(ASCE)1090-0268(2007)11:1(42)10.1061/(ASCE)1090-0268(2007)11:1(42) ↗
23. 10.1061/(ASCE)1090-0268(2004)8:2(97)10.1061/(ASCE)1090-0268(2004)8:2(97) ↗
24. 10.1061/(ASCE)1090-0268(2008)12:1(93)10.1061/(ASCE)1090-0268(2008)12:1(93) ↗
25. 10.1061/(ASCE)1090-0268(2001)5:3(146)10.1061/(ASCE)1090-0268(2001)5:3(146) ↗
26. Punurai W. Chen J. and Hsu C. (2009). “RC slender columns strengthened by CFRP composite fabrics subjected to biaxial bending and axial compression.” Proc. 9th Int. Symp. on Fiber-Reinforced Polymer Reinforcement for Concrete Structures (FRPRCS-9).
27. Ranger M. and Bisby L. (2007). “Effects of load eccentricities on circular FRP confined reinforced concrete columns.” Proc. 8th Int. Symp. on Fiber-Reinforced Polymer Reinforcement for Concrete Structures (FRPRCS-8) Univ. of Patras Patras Greece.
28. 10.1061/(ASCE)1090-0268(2008)12:1(80)10.1061/(ASCE)1090-0268(2008)12:1(80) ↗
29. Flexural behavior of concrete columns retrofitted with carbon fiber-reinforced polymer jackets
30. 10.1061/(ASCE)1090-0268(2009)13:2(125)10.1061/(ASCE)1090-0268(2009)13:2(125) ↗
31. 10.1144/GSL.SP.2004.238.01.2110.1144/GSL.SP.2004.238.01.21 ↗
32. Flexural behavior of concrete beams strengthened with near-surface-mounted CFRP strips
33. Youcef Y. Amziane S. and Chemrouk M. (2008). “The influence of CFRP on the behavior of reinforced concrete subjected to buckling.” Proc. 4th Int. Conf. on FRP Composites in Civil Engineering (CICE 2008) EMPA Zürich Switzerland.