journal article·2016-10Open access

Experimental Study on FRP Tube Reinforced Concrete Columns under Different Loading Conditions

Weiqiang Wang, M. Neaz Sheikh, Muhammad N. S. Hadi

Abstract

The behavior of fiber-reinforced polymer (FRP) tube reinforced concrete (FTRC) columns under different loading conditions was investigated in this study. Four groups of 16 specimens were cast and tested. Specimens in the first group (the reference group) were reinforced with longitudinal steel bars and steel helices (Group REF). Specimens in the second group were reinforced with intact glass FRP tubes (Group IT). Specimens in the third group were also reinforced with intact glass FRP tubes. In addition, polymer grid was embedded into the concrete cover to reduce the cover spalling (Group ITG). Specimens in the fourth group were reinforced with perforated glass FRP tubes (Group PT). One specimen from each group was tested under concentric loading, one under 25-mm eccentric loading, one under 50-mm eccentric loading, and one under four-point loading. Results from the experimental study show that FRP tubes significantly increase the load-carrying capacity and ductility of FTRC specimens. Group ITG specimens performed better than the other groups of specimens. Experimental and analytical interaction (P−M) diagrams also show the enhanced performance of FTRC specimens.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Ph.D. Candidate, School of Civil, Mining, and Environmental Engineering, Univ. of Wollongong, Wollongong, NSW 2522, Australia.

Senior Lecturer, School of Civil, Mining, and Environmental Engineering, Univ. of Wollongong, Wollongong, NSW 2522, Australia.

Associate Professor, School of Civil, Mining, and Environmental Engineering, Univ. of Wollongong, Wollongong, NSW 2522, Australia (corresponding author).

References (39)

Show source-provided references
1. AS (Australian Standard). (2007). “Metallic materials—Tensile testing at ambient temperature.” AS 1391:2007 Sydney NSW Australia.
2. AS (Australian Standard). (2009). “Concrete structures.” AS 3600:2009 Sydney NSW Australia.
3. 10.1061/(ASCE)CC.1943-5614.000035510.1061/(ASCE)CC.1943-5614.0000355 ↗
4. China Planning Press. (2010). “Technical code for infrastructure application of FRP composites.” GB-50608 Beijing.
5. Chinese Standard. (2005). “Test method for longitudinal compressive properties of fiber-reinforced thermosetting plastic pipe.” GB/T 5350-2005 Beijing.
6. 10.1016/j.firesaf.2012.08.00610.1016/j.firesaf.2012.08.006 ↗
7. 10.1016/j.conbuildmat.2010.11.09610.1016/j.conbuildmat.2010.11.096 ↗
8. 10.1061/(ASCE)CC.1943-5614.000011610.1061/(ASCE)CC.1943-5614.0000116 ↗
9. Exel Composites Australia. (2015). “Tubes.” ⟨http://www.exelcomposites.com/fi-fi/english/products/tubes.aspx⟩ (Jun. 1 2015).
10. Experimental and analytical modeling of concrete-filled fiber-reinforced polymer tubes subjected to combined bending and axial loads
11. Behavior of axially loaded concrete-filled circular fiber-reinforced polymer tubes
12. 10.1061/(ASCE)1090-0268(2002)6:2(123)10.1061/(ASCE)1090-0268(2002)6:2(123) ↗
13. Geofabrics. (2015). “Miragrid GX geogrids.” ⟨http://www.geofabrics.com.au/products/products/55-miragridtrade-gx-geogrids/overview⟩ (Feb. 1 2016).
14. 10.1016/j.cemconcomp.2006.07.00810.1016/j.cemconcomp.2006.07.008 ↗
15. Use of helices in reinforced concrete beams
16. 10.1016/j.conbuildmat.2015.02.02510.1016/j.conbuildmat.2015.02.025 ↗
17. 10.1061/(ASCE)MT.1943-5533.000023410.1061/(ASCE)MT.1943-5533.0000234 ↗
18. 10.1016/j.conbuildmat.2010.12.01710.1016/j.conbuildmat.2010.12.017 ↗
19. 10.1016/j.cemconcomp.2007.09.00910.1016/j.cemconcomp.2007.09.009 ↗
20. 10.1016/j.compstruct.2007.10.01310.1016/j.compstruct.2007.10.013 ↗
21. 10.1061/(ASCE)1090-0268(2003)7:3(238)10.1061/(ASCE)1090-0268(2003)7:3(238) ↗
22. 10.1061/(ASCE)0733-9445(2006)132:3(449)10.1061/(ASCE)0733-9445(2006)132:3(449) ↗
23. 10.1061/(ASCE)0733-9445(1988)114:8(1804)10.1061/(ASCE)0733-9445(1988)114:8(1804) ↗
24. 10.1061/(ASCE)1090-0268(1998)2:4(175)10.1061/(ASCE)1090-0268(1998)2:4(175) ↗
25. 10.1016/j.engstruct.2010.08.02310.1016/j.engstruct.2010.08.023 ↗
26. 10.1016/j.engstruct.2013.01.01710.1016/j.engstruct.2013.01.017 ↗
27. 10.1061/(ASCE)ST.1943-541X.000130310.1061/(ASCE)ST.1943-541X.0001303 ↗
28. Axial load behavior of large-scale spirally-reinforced high-strength concrete columns
29. 10.1016/j.conbuildmat.2013.08.08210.1016/j.conbuildmat.2013.08.082 ↗
30. 10.1016/0008-8846(73)90096-310.1016/0008-8846(73)90096-3 ↗
31. 10.1016/j.conbuildmat.2012.08.01710.1016/j.conbuildmat.2012.08.017 ↗
32. 10.1061/(ASCE)0733-9445(2008)134:5(750)10.1061/(ASCE)0733-9445(2008)134:5(750) ↗
33. 10.1061/(ASCE)CC.1943-5614.000001210.1061/(ASCE)CC.1943-5614.0000012 ↗
34. Axial compressive behaviour of concrete confined with polymer grid
35. 10.1016/j.tws.2015.06.01910.1016/j.tws.2015.06.019 ↗
36. 10.1016/j.compstruct.2012.11.02310.1016/j.compstruct.2012.11.023 ↗
37. 10.1061/(ASCE)CC.1943-5614.000001010.1061/(ASCE)CC.1943-5614.0000010 ↗
38. 10.1016/j.compstruct.2012.12.02810.1016/j.compstruct.2012.12.028 ↗
39. 10.1260/1369-4332.13.5.96110.1260/1369-4332.13.5.961 ↗