journal article·2004-12

Axial and Shear Behavior of Glass Fiber Reinforced Gypsum Wall Panels: Tests

Yu-Fei Wu, Mike P. Dare

Publisher page

Abstract

Glass fiber reinforced gypsum (GFRG) walls and their associated building system are the new building product and building system that have been developed in the Australian building industry in the last decade. GFRG walls are factory made glass-fiber reinforced gypsum hollow walling panels with/without in situ reinforced concrete filling inside the cavities. GFRG can be used as various structural elements, such as walls and slabs. GFRG, in its short life, without extensive product development and comprehensive structural design guidelines, has been used as the principal wall construction material in more than 3,000 dwellings across Australia. As GFRG walls find more and more applications and interests in the building industry in Australia as well as in other countries, comprehensive structural design guidelines for GFRG walls and their building system have become necessary. Comprehensive experimental testing and theoretical studies started in 2002 as an international research and development program to develop structural design guidelines for GFRG walls. The axial and shear tests are reported in this paper.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Masonry and Concrete Structural Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Assistant Professor, Dept. of Building and Construction, City Univ. of Hong Kong, Tat Chee Ave., Kowloon, Hong Kong (corresponding author); E-mail: yfwu00@cityu.edu.hk; formerly, Australian Postdoctoral Fellow, Dept. of Civil and Environmental Engineering, Univ. of Adelaide, South Australia 5005, Australia.

Director, Dare Sutton Clarke Engineers, 276 Flinders St., Adelaide, South Australia 5000, Australia.

References (11)

Show source-provided references
1. Burnett E. Arenja A. and Holroyd L. ( 1996). “An innovative plastic housing system.” Materials for the New Millennium Proc. 4th Materials Engineering Conf. Vol. 1 K. P. Chong ed. Materials Engineering Div. ASCE New York 545–554.
2. Hidalgo P.A. Mayes R.L. McNiven H.D. and Clough R.W. ( 1978). “Cyclic loading tests of masonry single piers. Volume 3—Height to width ratio of 0.5.” Rep. No. UCB/EERC-78/27 Earthquake Engineering Research Center Univ. of California Berkeley Calif.
3. Liddell D.P. ( 2000). “Influence of loading history on ultimate displacement of concrete structures.” MEng thesis Univ. of Auckland Auckland New Zealand.
4. Liddell D.P. Ingham J.M. and Davidson B.J. ( 2001). “Influence of loading history on the ultimate displacement of ductility 6–current design concrete structure.” Proc. Australian Structural Engineering Conf. 231–238.
5. McMullin K. and Merrick D. ( 2002). “Seismic performance of gypsum walls: Experimental test program.” CUREE Rep. No. W-15 Consortium of Universities for Research in Earthquake Engineering Calif.
6. Omahen R. ( 2002). “Ecologically sustainable development: Approaches in the construction industry.” Master of economics thesis Faculty of Economics University of Regensburg Regensburg Germany.
7. Paulay T. and Priestley M.J. N. ( 1992). Seismic design of reinforced concrete and masonry buildings Wiley New York.10.1002/9780470172841 ↗
8. 10.1061/(ASCE)0733-9445(1994)120:8(2310)10.1061/(ASCE)0733-9445(1994)120:8(2310) ↗
9. Standards Australia International. ( 2001). “Concrete structures.” AS 3600-2001 Sydney Australia.
10. 10.1061/(ASCE)0733-9445(2003)129:9(1183)10.1061/(ASCE)0733-9445(2003)129:9(1183) ↗
11. 10.1081/SME-12000442010.1081/SME-120004420 ↗