Flexural Behavior of a Carbon Fiber–Reinforced Polymer Prestressed Decked Bulb T-Beam Bridge System
Source abstract
Abstract
Experimental and numerical investigations were conducted to evaluate the performance of a newly developed bridge system. Through the investigation, a decked bulb T-beam bridge model was constructed, instrumented, and tested under service and ultimate loads. The bridge model had a width of 2.59 m (8.5 ft), an effective span of 9.45 m (31 ft), a depth of 356 mm (14 in.), and was composed of five adjacent decked bulb T-beams. The T-beams were interconnected at their top flanges using 76-mm (3-in.)-wide ultra-high-performance concrete (UHPC) shear key joints and five full-depth equally spaced transverse diaphragms along the span. Each diaphragm was posttensioned with two nonbonded transverse carbon fiber composite cable (CFCC) strands. The investigation revealed that the developed decked bulb T-beam bridge system maintained its structural integrity under service loads with signs of distress in neither the shear key joints nor top flanges. UHPC shear keys with the transverse diaphragms were adequate to achieve monolithic action across the width of the bridge model. In addition, transverse posttensioning forces were effective in restoring the structural integrity of the bridge model when cracks were artificially induced in the shear key joints. At the ultimate limit state the bridge model exhibited compression failure by crushing of the concrete in the top flange. The compression failure was associated with low ductility, a dense cracking pattern, and excessive deflection.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Dean and University Distinguished Professor, College of Engineering, Lawrence Technological Univ., Southfield, MI 48075.
Senior Engineer, Cable Technologies North America, 26200 Town Center Dr., Novi, MI 48375.
Graduate Student, Center for Innovative Materials Research, Lawrence Technological Univ., Southfield, MI 48075.
Postdoctoral Research Fellow, Center for Innovative Materials Research, Lawrence Technological Univ., Southfield, MI 48075 (corresponding author).
References (21)
Show source-provided references
1. ABAQUS 6.11-2 [Computer software]. Dassault Systèmes Waltham MA.
2. ASTM. (2004). “Standard test method for tensile strength of concrete surfaces and the bond strength or tensile strength of concrete repair and overlay materials by direct tension (pull-off method).” C1583-04 West Conshohocken PA.
3. ASTM. (2005). “Standard test method for bond strength of epoxy-resin systems used with concrete by slant shear.” C882-05 West Conshohocken PA.
4. ASTM. (2007). “Standard test method for flow of hydraulic cement mortar.” C1437-07 West Conshohocken PA.
5. ASTM. (2010). “Standard test method for flexural strength of concrete (using simple beam with third-point loading).” C78-10 West Conshohocken PA.
6. ASTM. (2011). “Standard test method for splitting tensile strength of cylindrical concrete specimens.” C496/496M-11 West Conshohocken PA.
7. ASTM. (2012). “Standard test method for compressive strength of cylindrical concrete specimens.” C39/39M-12 West Conshohocken PA.
8. Baah P. (2012). “Development of innovative CFRP prestressed decked bulb T beam bridge system.” M.S. thesis Civil Engineering Dept. Lawrence Technological Univ. Southfield MI.
9. Bache H. (1981). “Densified cement ultra-fine particle-based materials.” Proc. 2nd Int. Conf. on Superplasticizers in Concrete American Concrete Institute Farmington Hills MI.
10. Bhide S. (2008). “Material usage and condition of existing bridges in the US.” Rep. No. SR34204 Portland Cement Association Skokie IL.
11. French C. E. et al. (2011). “Cast-in-place concrete connections for precast deck systems.” National Cooperative Highway Research Program Rep. No. 173 Washington DC.
12. 10.1061/(ASCE)CC.1943-5614.000026610.1061/(ASCE)CC.1943-5614.0000266 ↗
13. 10.15554/pcij.03012012.48.6310.15554/pcij.03012012.48.63 ↗
14. 10.1061/(ASCE)1090-0268(1998)2:4(186)10.1061/(ASCE)1090-0268(1998)2:4(186) ↗
15. Graybeal B. A. (2006). “Structural behavior of ultra-high performance concrete prestressed I-girders.” Federal Highway Administration (FHWA) Rep. No. FHWA-HRT-06-115 Washington DC.
16. Graybeal B. A. (2011). “Fatigue response in bridge deck connection composed of field-cast ultra-high-performance concrete.” Transportation Research Record 2251 Transportation Research Board Washington DC 93–100.10.3141/2251-10 ↗
17. 10.1061/(ASCE)BE.1943-5592.000009710.1061/(ASCE)BE.1943-5592.0000097 ↗
18. 10.15554/pcij.11011999.80.9010.15554/pcij.11011999.80.90 ↗
19. Oesterle R. G. and Elremaily A. F. (2009). “Design and construction guidelines for long-span decked precast prestressed concrete girder bridge.” Final Rep. National Cooperative Highway Research Program (NCHRP) Project No. 12-69 Washington DC.
20. 10.15554/pcij.01011987.86.10310.15554/pcij.01011987.86.103 ↗
21. Tokyo Rope. (2012). “Technical data on CFCC.” Manufacturer Rep. Tokyo Japan.