journal article·2015-04

Tensile and Lap-Splice Shear Strength Properties of CFRP Composites at High Temperatures

Duncan Cree, Taras Gamaniouk, Marc Li Loong, Mark F. Green

Publisher page

Abstract

Carbon fiber–reinforced polymer (CFRP) composites are used to retrofit or reinforce existing civil infrastructure. When a new combination of carbon fiber/epoxy system is to be implemented, elevated temperature requirements must be evaluated to determine performance in fire or hot climates. This article presents experimental results conducted on small-scale CFRP laminates produced by the hand layup technique to determine tensile strength and single lap-splice shear strength at temperatures from 23 to 200°C. Two curing regimes were evaluated: room temperature (23°C) and elevated temperature (120°C). The dynamic mechanical analyzer was used to determine the glass transition values from each curing regime. Strength tests were performed at steady-state (heat, then load to failure) and transient (hold load, increase temperature to failure) temperatures. Loss of tensile strength and modulus at elevated temperature is thought to be due to polymer resin matrix softening and loss of load transfer capability from fiber to fiber, whereas failure of the tensile bond strength between the two laminates is believed to be due to the degradation of the polymer resin matrix material. Analysis of variance (ANOVA) one-way statistical analysis has shown that CFRP composite specimens have a statistically significant loss in tensile strength, stiffness, and bond strength as the test temperature was increased but are not statistically significant when grouped above and below the glass transition temperature.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Fire effects on concrete materials · Mechanical Behavior of Composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Assistant Professor, Dept. of Civil Engineering, Queen’s Univ., Kingston, ON, Canada K7 L 3N6 (corresponding author).

Summer Internship Undergraduate Student, Dept. of Civil Engineering, Queen’s Univ., Kingston, ON, Canada K7 L 3N6.

Professor, Dept. of Civil Engineering, Queen’s Univ., Kingston, ON, Canada K7 L 3N6.

References (29)

Show source-provided references
1. 10.1016/j.compositesb.2005.05.01610.1016/j.compositesb.2005.05.016 ↗
2. American Concrete Institute (ACI). (2008). “Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures.” 440.2 R-08 Farmington Hills MI.
3. ASTM. (2010). “Standard test method for determining tensile properties of fiber reinforced polymer matrix composites used for strengthening of civil structures.” D7565/D7565M-10 West Conshohocken PA.
4. ASTM. (2011). “Standard test method for determining apparent overlap splice shear strength properties of wet lay-up fiber-reinforced polymer matrix composites used for strengthening civil structures.” D7616/D7616M-11 West Conshohocken PA.
5. ASTM. (2013). “Standard test method for assignment of the glass transition temperature by dynamic mechanical analysis.” E1640-13 West Conshohocken PA.
6. 10.1016/j.matdes.2011.04.06110.1016/j.matdes.2011.04.061 ↗
7. Balaguru P. · 2009 · 67
8. 10.1002/pse.19810.1002/pse.198 ↗
9. Bisby L. A. Take W. A. and Caspary A. (2007). “Quantifying strain variation in FRP confined concrete using digital image correlation: Proof-of-concept and initial results.” Proc. 1st Asia-Pacific Conf. on FRP in Structures Hong Kong Univ. Hong Kong 599–604.
10. Mechanical characterization of fibre reinforced polymer materials at high temperature
11. 10.1016/j.firesaf.2012.08.00610.1016/j.firesaf.2012.08.006 ↗
12. 10.1016/j.compositesa.2011.06.01610.1016/j.compositesa.2011.06.016 ↗
13. 10.1016/j.compositesb.2006.06.00210.1016/j.compositesb.2006.06.002 ↗
14. 10.1016/j.conbuildmat.2010.04.06210.1016/j.conbuildmat.2010.04.062 ↗
15. 10.1533/978184569489010.1533/9781845694890 ↗
16. 10.1002/(SICI)1097-4628(19990801)73:5<649::AID-APP5>3.0.CO;2-B10.1002/(SICI)1097-4628(19990801)73:5<649::AID-APP5>3.0.CO;2-B ↗
17. Bond strength of CFRP and steel bars in concrete at elevated temperature
18. Menard K. P. · 2002 · 563
19. 10.1002/(SICI)1098-2329(199924)18:4<351::AID-ADV6>3.0.CO;2-X10.1002/(SICI)1098-2329(199924)18:4<351::AID-ADV6>3.0.CO;2-X ↗
20. 10.1016/j.compstruct.2007.06.00710.1016/j.compstruct.2007.06.007 ↗
21. Schwartz M. M. · 2002
22. 10.1016/j.compositesb.2012.03.00210.1016/j.compositesb.2012.03.002 ↗
23. Sika Canada. (2012a). “Technical data sheet for SikaBiresin.” Pointe-Claire QC Canada.
24. Sika Canada. (2012b). “Technical data sheet for Sikadur 330.” Pointe-Claire QC Canada.
25. Sika Canada. (2012c). “Technical data sheet for SikaWrap Hex 230 C.” Pointe-Claire QC Canada.
26. 10.1016/j.engstruct.2011.03.00610.1016/j.engstruct.2011.03.006 ↗
27. 10.1680/geot.2003.53.7.61910.1680/geot.2003.53.7.619 ↗
28. Experimental study on CFRP-bonded steel plates with thickness reduction using underwater epoxy
29. Fiber reinforced polymer materials in construction applications