Damage Detection of FRP-Strengthened Concrete Structures Using Capacitance Measurements
Source abstract
Abstract
In this study, a new concept for detecting air voids, water intrusion, and glue infiltration damages in fiber-reinforced polymers (FRPs)-strengthened concrete structures was developed. The concept, based on detecting the local dielectric permittivity variations, was employed to design coplanar capacitance sensors (CCSs) to detect such defects. An analytical model was used to introduce the sensor operation theory and analyze the influence of different sensor parameters on the output signals and to optimize sensor design. Two dimensional finite element (FE) simulations were performed to assess the validity of the analytical results and to evaluate other sensor design-related parameters. To experimentally verify the FE model, dielectric properties of various materials involved in FRP-strengthened concrete systems were measured. In addition, two concrete specimens strengthened with FRP laminates and containing preinduced defects were constructed and inspected in a laboratory setting. Good agreement was found between experimental capacitance measurements and those predicated by the FE simulations. The proposed CCS design, coupled with commercially available portable capacitance meters, would facilitate field implementation of the proposed technique for rapid inspection of FRP-strengthened concrete structures without the need for sophisticated data analyses usually required by other more expensive and time consuming methods.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Structural Health Monitoring Techniques · Smart Materials for Construction
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Graduate Student, Dept. of Civil Engineering, McMaster Univ., Centre for Effective Design of Structures, Hamilton ON, Canada L8S 4L7 (corresponding author).
Assistant Professor, Dept. of Civil Engineering, McMaster Univ., Centre for Effective Design of Structures, Hamilton ON, Canada L8S 4L7.
References (16)
Show source-provided references
1. 10.1109/22.78040710.1109/22.780407 ↗
2. Chang F. H. · 1975 · 176
3. 10.1109/MMW.2003.123747810.1109/MMW.2003.1237478 ↗
4. Hillger W. Ahrholdt M. Rohling H. and Henrich R. (2004). “Non-contact ultrasonic imaging techniques for composite components.” Proc. 16th World Conf. on Nondestructive Testing Montréal Canada.
5. 10.1016/S0963-8695(97)00029-710.1016/S0963-8695(97)00029-7 ↗
6. 10.1016/j.compstruct.2004.09.01510.1016/j.compstruct.2004.09.015 ↗
7. 10.1109/22.29780510.1109/22.297805 ↗
8. Li X. B. Larson S. D. Zyuzin A. S. and Mamishev A. V. (2004). “Design of multichannel fringing electric field sensors for imaging. Part I. General design principles.” Proc. IEEE Int. Symp. on Electrical Insulation 406–409.
9. Maxwell 2D . (2003). Ansoft Corporation V.10 Pittsburgh Pa.
10. 10.1016/S0266-3538(99)00094-910.1016/S0266-3538(99)00094-9 ↗
11. Schinzinger R. · 1991
12. 10.1061/(ASCE)0899-1561(2003)15:3(266)10.1061/(ASCE)0899-1561(2003)15:3(266) ↗
13. Ulaby F. T. · 2005
14. 10.1134/1.125930010.1134/1.1259300 ↗
15. Ying Z. Zhuo L. and Weiping S. (2007). “Fast capacitance extraction in multilayer conformal and embedded dielectric using hybrid boundary element method.” Proc. Design Automation Conf. DAC ’07. 44th ACM/IEEE San Dieego Calif. 835–840.10.1145/1278480.1278687 ↗
16. 10.1002/mop.2147810.1002/mop.21478 ↗