journal article·2013-10

Experimental Study on Full-Scale Pretensioned Bridge Girder Damaged by Vehicle Impact and Repaired with Fiber-Reinforced Polymer Technology

David Cerullo, Khaled Sennah, Hossein Azimi, Clifford Lam, Amir Fam, Bala Tharmabala

Publisher page

Abstract

A bridge was damaged when a dump truck violated the height clearance limitation on Highway 401 in Ontario, Canada. The collision caused extensive damage to the AASHTO Type-III precast/prestressed bridge girders, which led to the closure of the two-lane bridge. Crack mapping showed extensive torsion-shear cracks between the girder quarter points, horizontal crack at the flange-web junctions, and spalled concrete at point of impact. Preliminary elastic testing on the girder established that the flexural capacity of the girder had not been significantly affected. As such, flexural strengthening was not necessary. Crack patterns and severity, followed by analysis, have shown that the girder is deficient in shear capacity. Therefore, the girder was strengthened for shear throughout its entire length using carbon fiber–reinforced polymer (CFRP) sheets. This paper presents a summary of the design and detailing of the elastic behavior test conducted before repair, the girder repair methodology, and results from proof load testing of the repaired girder. It was shown that the rehabilitated girder could sustain flexural live load demand. A field application was also carried out using the same rehabilitation technique on another impact-damaged bridge in Ontario. It was viewed as a major budget-saving project compared to the girder replacement alternative, because of the speed of rehabilitation and the minor traffic disruptions.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Bridge Engineer, McCormick Rankin Corp., 2655 N. Sheridan Way, Suite 300, Mississauga, ON, Canada L5K 2P8; formerly, Graduate Student, Civil Engineering Dept., Ryerson Univ., Toronto ON.

Professor, Civil Engineering Dept., Ryerson Univ., 350 Victoria, Toronto, ON, Canada M5B 2K3.

Postdoctoral Fellow, Civil Engineering Dept., Ryerson Univ., 350 Victoria, Toronto, ON, Canada M5B 2K3 (corresponding author).

Head, Bridge Research, Bridge Office, Ontario Ministry of Transportation, 301 St. Paul Street, St. Catharine, ON, Canada L2R 7R3.

Professor and Canada Research Chair, Dept. of Civil Engineering, Queens Univ., 58 University Ave., Kingston, ON, Canada K7L 3N6.

Head of Bridge Engineering Office at McIntosh Perry Consulting Engineers Ltd., 192 Hickson Ave., Kingston, ON, Canada K7K 2N9.

References (21)

Show source-provided references
1. AASHTO · 2009
2. American Concrete Institute (ACI). (2008). “Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures.” ACI 440.2R-08 Farmington Hills MI.
3. AutoCAD [Computer software]. Autodesk Inc. San Rafael CA.
4. 10.1061/(ASCE)1090-0268(2002)6:2(73)10.1061/(ASCE)1090-0268(2002)6:2(73) ↗
5. FRP bars for bridges
6. Externally bonded fiber reinforced polymers for rehabilitation of corrosion damaged concrete beams
7. Shear strengthening reinforced concrete beams with fiber-reinforced polymer: Assessment of influencing parameters and required research
8. Increased flexural capacity of reinforced concrete beams using carbon fiber reinforced polymer composites
9. Canadian Standards Association. (2002). “Design and construction of building components with fibre reinforced polymers.” CAN/CSA-S806-02 Toronto.
10. Canadian Standards Association. (2006). “Canadian highway bridge design code (CHBDC).” CAN/CSA-S6 Toronto ON.
11. Cerullo D. (2006). “Strengthening full-scale damaged prestressed concrete bridge girders with CFRP sheets.” M.A.SC. thesis Civil Engineering Dept. Ryerson Univ. Toronto.
12. ElSafty A. and Graef M. (2012). “The repair of damaged bridge girders with CFRP laminates.” Rep. No. BDK82 977-03 State of Florida Department of Transportation Tallahassee FL.
13. Load testing a CFRP-reinforced bridge
14. 10.1061/(ASCE)1084-0702(2008)13:1(15)10.1061/(ASCE)1084-0702(2008)13:1(15) ↗
15. 10.1139/l00-02810.1139/l00-028 ↗
16. Structural engineering with FRP-In Canada
17. Sennah K. Cerullo D. and Fam A. (2007). “Rehabilitation and testing to-collapse of a damaged PC girder.” Bridge Office Ministry of Transportation of Ontario St. Catherine ON.
18. Application of fibre reinforced polymers in rapid repair of bridge girders damaged by vehicle impact
19. 10.1061/(ASCE)1084-0702(2000)5:2(107)10.1061/(ASCE)1084-0702(2000)5:2(107) ↗
20. 10.1016/S0950-0618(02)00088-010.1016/S0950-0618(02)00088-0 ↗
21. Many innovations make light work: Dingman Drive Bridge repaired using a suite of cost-saving innovations