This paper reports on the field study of a steel stringer-fiber reinforced polymer (FRP) deck composite bridge in Pennsylvania. The objective of the study is to assess the effective compression flange width in the FRP deck and floor systems when they act compositely with underlying steel girders at service conditions. The research results reported herein support the notion of employing a design approach, for both interior and exterior girders of a composite floor system, that is philosophically consistent with current practice related to steel girders acting compositely with concrete decking. It appears from the results presented herein that FRP decks and floors acting compositely with underlying steel girders exhibit an effective width that is close to the actual girder spacing for interior beams, and approximately one-half this value for exterior beams.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Engineering and Vibration Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Research Assistant, Dept. of Civil and Environmental Engineering, Univ. of Pittsburgh, 936 Benedum Hall, Pittsburgh, PA 15261.

Associate Professor and William Kelper Whiteford Faculty Fellow, Dept. of Civil and Environmental Engineering, Univ. of Pittsburgh, 936 Benedum Hall, Pittsburgh, PA 15261.

Doctoral Student, Dept. of Civil and Environmental Engineering, Univ. of Pittsburgh, 936 Benedum Hall, Pittsburgh, PA 15261.

References (9)

Show source-provided references
1. Ahmadi A. (1996). “Full scale test of half depth grid on upper buckeye bridge to determine effective flange width live load distribution and grid deck stresses.” Bridge Grid Flooring Manufacturers Report Pittsburgh.
2. American Association of State Highway and Transportation Officials (AASHTO). (1998). “LRFD bridge specification.” American Assoc. of State Highway and Transportation Officials Washington D.C.
3. American Institute of Steel Construction. (AISC). (1999). Load and resistance factor design specification for structural steel buildings LRFD 3rd Ed. American Institute of Steel Construction Chicago.
4. ASCE. (1979). “Structural design of tall steel buildings.” ASCE New York.
5. Jayas B. S. and Hosain M. U. (1988). “Composite beams with perpendicular ribbed metal deck.” Proc. Composite Construction in Steel and Concrete ASCE New York 511–526.
6. Keelor D. C. (2002). “Design construction and deployment of a compact robust field data acquisition system for structural field monitoring.” MS thesis Univ. of Pittsburgh Pittsburgh.
7. 10.1061/(ASCE)0733-9445(2002)128:6(762)10.1061/(ASCE)0733-9445(2002)128:6(762) ↗
8. Shear strength of stud connectors in lightweight and normal-weight concrete.10.62913/engj.v8i2.160 ↗
9. Turner K. and Harries K. A. (2002). “Tests of shear stud connections between GFRP bridge decks and steel girders.” draft final report Rep. No. ST02-03-LD Dept. of Civil and Environmental Engineering Univ. of South Carolina Columbia S.C.