journal article·2006-08

Residual Performance of FRP-Retrofitted RC Columns after Being Subjected to Cyclic Loading Damage

Bo Shan, Yan Xiao, Yurong Guo

Publisher page

Abstract

Numerous recent research findings evidenced the success of retrofitting existing RC columns using fiber-reinforced plastic (FRP) jacketing. However, little is known about the residual performance of FRP-retrofitted RC columns following limited seismic damage. In this paper, the residual performance of FRP-retrofitted columns damaged after simulated seismic loading is studied. Eight model columns with a shear aspect ratio of 5.0 were tested first under cyclic lateral force and a constant axial load equal to 20% of the column gross axial load capacity. The main parameters considered were the type of FRP jacket and peak drift ratio where the lateral loading was interrupted. Glass fiber-reinforced plastic (GFRP) and carbon fiber-reinforced plastic (CFRP) were both used for retrofitting. Five of the model columns were subjected to long-term axial loading after being subjected to limited damage by lateral cyclic loading. From the results of long-term loading test, it was found that FRP-retrofitted columns had much smaller creep deformation than the counterpart as-built model. The deformation of retrofitted columns under long-term axial loading depended on the previous damage intensity and the modulus of elasticity of FRP. The effective creep Poisson’s ratios of the retrofitted columns were much smaller than the as-built column but identical for GFRP and CFRP retrofitted columns. Under the testing conditions of this study, the long-term axial deformation of retrofitted columns tends to be sufficiently stable, despite the simulated earthquake damage.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Research Assistant, CIPRES, Hunan Univ., Changsha, China.

Professor, Dept. of Civil Engineering, Univ. of Southern California, Los Angeles, CA 90089 (corresponding author). E-mail: yanxiao@usc.edu; jointly, Cheung Kong Scholar, Director of CIPRES, Hunan Univ., Changsha, China.

Associate Professor, CIPRES, Hunan Univ., Changsha, China.

References (16)

Show source-provided references
1. American Concrete Institute (ACl). (1971). “Prediction of creep shrinkage and temperature effects in concrete structures.” Committee 209 Rep. ACI-SP27 Detroit 51–93.
2. American Concrete Institute (ACl). (1992). “Prediction of creep shrinkage and temperature effects in concrete structures.” Committee 209 Rep. ACI 209R-92 Farmington Hills Mich.
3. American Concrete Institute (ACl). (2002). “Building code requirements for reinforced concrete and commentary.” Committee 318 Rep. ACI 318-02/ACI 418R-02 Farmington Hills Mich.
4. American Concrete Institute (ACl). (2000). “Guide for the design and strengthening of externally bonded FRP systems for strengthening concrete structures.” Committee 440 Draft Rep. Farmington Hills Mich.
5. Effect of confinement using FRP or FRC on seismic performance of gravity load-designed column
6. Hipley P. · 2004
7. 10.1193/1.158607010.1193/1.1586070 ↗
8. Time-dependent behavior of fiber-reinforced polymer confined columns under axial loads
9. Strength and ductility of concrete columns reinforced with fiber composite straps
10. Seismic strengthening of circular bridge pier models with fiber composite straps
11. Seismic behavior of concrete columns confined with steel and fiber-reinforced polymers
12. 10.1260/136943304165355210.1260/1369433041653552 ↗
13. 10.1061/(ASCE)0733-9445(1997)123:10(1357)10.1061/(ASCE)0733-9445(1997)123:10(1357) ↗
14. Xiao Y. · 2001 · 731
15. 10.1061/(ASCE)0899-1561(2000)12:2(139)10.1061/(ASCE)0899-1561(2000)12:2(139) ↗
16. 10.1061/(ASCE)0733-9445(1999)125:3(255)10.1061/(ASCE)0733-9445(1999)125:3(255) ↗