journal article·2011-02

Mechanism of Bond Behavior of Concrete Beams Strengthened with Near-Surface-Mounted CFRP Rods

Noran Wahab, Khaled A. Soudki, Timothy Topper

Publisher page

Abstract

Bond tests were conducted on concrete beams strengthened with near-surface-mounted (NSM) nonprestressed and prestressed carbon fiber-reinforced polymer (CFRP) rods under static loading. In the NSM technique, the CFRP rods are placed inside precut grooves and bonded to the concrete with epoxy adhesive. Six concrete beams were tested. The test variables included presence of internal tension steel reinforcement (unreinforced and reinforced), use of NSM CFRP strengthening (nonprestressed and prestressed), and type of CFRP rod (spirally wound and sand blasted). The beams were tested statically in four-point bending. Based on the test results, the transfer length for the prestressed CFRP rod in epoxied groove was 150 and 210 mm for the sand blasted and spirally wound rods, respectively. The main failure mode was debonding between the CFRP rod and the epoxy that starts at sections close to the midspan then, as the load increases, it propagates toward the supports. At failure, the beams strengthened with a given rod type showed the same CFRP strain at sections close to the support (29% of ultimate strain for spirally wound bars and 39% of ultimate strain for sand blasted bars). A cracked section analysis was carried out and compared well with the measured results.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Ph.D. Student, Dept. of Civil and Environmental Engineering, Univ. of Waterloo, Waterloo, ON, Canada N2L 3G1.

Professor and Canada Research Chair, Dept. of Civil and Environmental Engineering, Univ. of Waterloo, Waterloo, ON, Canada N2L 3G1 (corresponding author).

Distinguished Professor Emeritus, Dept. of Civil and Environmental Engineering, Univ. of Waterloo, Waterloo, ON, Canada N2L 3G1.

References (14)

Show source-provided references
1. Al-Mayah A. (2004). “Interfacial behavior of CFRP-metal couples for wedge anchor systems.” Ph.D. thesis Univ. of Waterloo Waterloo Ont. Canada.
2. American Concrete Institute. (2008). “Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures.” ACI Committee 440 Farmington Hills Mich.
3. Badawi M. (2007). “ Monotonic and fatigue flexural behavior of RC beams strengthened with prestressed NSM CFRP rods.” Ph.D. thesis Dept. of Civil and Environmental Engineering Univ. of Waterloo Waterloo Ont. Canada.
4. Collins M. · 1987
5. Anchorage length of near-surface mounted FRP bars for concrete strengthening—Experimental investigation and numerical modeling
6. Bond between NSM bar-reinforced polymer rods and concrete in structural strengthening
7. 10.1016/S1359-8368(02)00052-510.1016/S1359-8368(02)00052-5 ↗
8. 10.1061/(ASCE)1090-0268(2003)7:3(248)10.1061/(ASCE)1090-0268(2003)7:3(248) ↗
9. Bond mechanism of near-surface mounted fiber reinforced polymer bars for flexural strengthening of concrete structures
10. 10.1061/(ASCE)1090-0268(2006)10:1(60)10.1061/(ASCE)1090-0268(2006)10:1(60) ↗
11. 10.1061/(ASCE)1090-0268(2008)12:3(323)10.1061/(ASCE)1090-0268(2008)12:3(323) ↗
12. 10.1260/13694330332241922310.1260/136943303322419223 ↗
13. Wahab N. Soudki K. A. and Topper T. (2008a). “Bond of carbon fiber reinforced polymer rods to concrete in near-surface mounted application under fatigue loading.” Proc. 2nd Canadian Conf. on Effective Design of Structures McMaster Univ. Hamilton Ont. Canada 195–205.
14. Wahab N. Soudki K. A. and Topper T. (2008b). “Preliminary investigation into the bond of prestressed near-surface mounted CFRP rods in concrete.” Proc. 5th Int. Conf. on Advanced Composite Materials in Bridges and Structures (ACMBS-V) Canadian Society of Civil Engineers Montreal No. 112.