journal article·2017-10

Comparison between ASTM D7205 and CSA S806 Tensile-Testing Methods for Glass Fiber–Reinforced Polymer Bars

Brahim Benmokrane, Claude Nazair, Xavier Seynave, Allan Manalo

Publisher page

Abstract

The standards ASTM D7205/D7205M-06 and CSA S806 contain the commonly used test methods for characterizing the tensile properties of glass fiber–reinforced polymer (GFRP) bars for use as reinforcement in concrete structures. These standards, however, use different anchor dimensions and loading rates, thereby possibly yielding different properties for the same type of fiber-reinforced polymer (FRP) bars. This paper assessed the results of a four-laboratory testing program comparing the sample preparation methods and test results according to ASTM D7205 and CSA S806. Each laboratory tested at least 10 samples prepared according to the recommendations in Annex A of the ASTM standard and Annex B of the Canadian Standards Association (CSA) standard. Each type of sample was prepared by a single laboratory to minimize variation among the test specimens. The results show a statistically significant difference between the tensile strength measured by using the CSA and ASTM provisions. Regardless of specimen preparation, the modulus of elasticity of the GFRP bars was the same with both test standards, but the ASTM standard returned a wider variation than did the CSA.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Professor of Civil Engineering, Tier-1 Canada Research Chair in Advanced Composite Materials for Civil Structures, and NSERC Chair in FRP Reinforcement for Concrete Structures, Dept. of Civil Engineering, Univ. of Sherbrooke, Sherbrooke, QC, Canada J1K 2R1 (corresponding author).

Professional Engineer, Infrastructure Materials Laboratory, Ministry of Transportation of Québec, Québec City, QC, Canada G1P 3W8.

Quality Systems Engineer, Pultrall, Thetford Mines, QC, Canada G6G 6Z5.

Senior Lecturer, Center for Future Materials, Faculty of Health, Engineering and Sciences, Univ. of Southern Queensland, Toowoomba, QLD 4350, Australia.

References (21)

Show source-provided references
1. 10.1016/j.matdes.2013.11.08110.1016/j.matdes.2013.11.081 ↗
2. 10.1061/(ASCE)1084-0702(2006)11:2(217)10.1061/(ASCE)1084-0702(2006)11:2(217) ↗
3. 10.1016/j.conbuildmat.2011.04.02810.1016/j.conbuildmat.2011.04.028 ↗
4. 10.1061/(ASCE)CC.1943-5614.000002710.1061/(ASCE)CC.1943-5614.0000027 ↗
5. 10.1061/(ASCE)1090-0268(1998)2:1(17)10.1061/(ASCE)1090-0268(1998)2:1(17) ↗
6. Gentry R. Bakis C. Harries K. Brown J. Prota A. and Parretti R. (2012). “Development of ASTM test methods for FRP composite materials: Overview and transverse shear.” Proc. 6th Int. Conf. on FRP Composites in Civil Engineering Rome.
7. 10.1016/j.compositesb.2004.05.00410.1016/j.compositesb.2004.05.004 ↗
8. 10.1016/j.conbuildmat.2015.05.04410.1016/j.conbuildmat.2015.05.044 ↗
9. Tensile and bond properties of GFRP reinforcing bars
10. Recent developments on FRP bars as internal reinforcement in concrete structures
11. 10.1016/j.engstruct.2015.08.00310.1016/j.engstruct.2015.08.003 ↗
12. 10.1016/j.engstruct.2016.03.03610.1016/j.engstruct.2016.03.036 ↗
13. 10.1016/j.conbuildmat.2004.04.01210.1016/j.conbuildmat.2004.04.012 ↗
14. 10.1016/j.compstruct.2007.04.01010.1016/j.compstruct.2007.04.010 ↗
15. 10.1061/(ASCE)CC.1943-5614.000009210.1061/(ASCE)CC.1943-5614.0000092 ↗
16. 10.1002/vnl.2139310.1002/vnl.21393 ↗
17. 10.1061/(ASCE)MT.1943-5533.000080710.1061/(ASCE)MT.1943-5533.0000807 ↗
18. SPSS ( Statistical Package for Social Sciences ) 23.0 [Computer software]. IBM Armonk NY.
19. Environmental effects on the mechanical properties of E-glass FRP rebars
20. 10.1016/S0266-3538(99)00053-610.1016/S0266-3538(99)00053-6 ↗
21. 10.1061/(ASCE)1090-0268(2001)5:2(85)10.1061/(ASCE)1090-0268(2001)5:2(85) ↗