Abstract
Fiber-reinforced polymer (FRP) strengthening systems for infill-masonry walls are typically designed to resist flexural stresses caused by out-of-plane pressure. Previous research has shown that there are potential premature failure mechanisms caused by shear sliding of the infill, which could reduce the effectiveness of the strengthening system. Current design guidelines for strengthening of masonry walls with FRP do not include guidelines for infill-masonry. This paper presents a rational approach for the design and analysis of FRP-strengthened infill-masonry walls subjected to out-of-plane loading, including the effect of using FRP end anchorage. The approach is based on consideration of four potential mechanisms: arching, shear sliding, debonding of the FRP in the overlap region, and failure of the FRP end-anchorage system. The predictions based on the proposed rational approach agree well with the measured values from two experimental programs.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Masonry and Concrete Structural Analysis · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Postdoctoral Scholar, Dept. of Civil, Construction, and Environmental Engineering, North Carolina State Univ., 2414 Campus Shore Dr., Campus Box 7533 Raleigh, NC 27695 (corresponding author).
Distinguished Professor, Dept. of Civil, Construction, and Environmental Engineering, North Carolina State Univ., 2414 Campus Shore Dr., Campus Box 7533 Raleigh, NC 27695.
References (9)
Show source-provided references
1. American Concrete Institute (ACI) Committee 440. (2010). “Guide for the design and construction of externally bonded fiber reinforced polymer systems for strengthening unreinforced masonry structures.” ACI 440.7R-10 Farmington Hills MI.
2. ASTM. (2007). “Standard specification for mortar for unit masonry.” C270-07 West Conshohocken PA.
3. 10.1061/(ASCE)1090-0268(2007)11:2(138)10.1061/(ASCE)1090-0268(2007)11:2(138) ↗
4. 10.1061/(ASCE)0733-9445(2008)134:10(1589)10.1061/(ASCE)0733-9445(2008)134:10(1589) ↗
5. 10.1061/(ASCE)CC.1943-5614.000009710.1061/(ASCE)CC.1943-5614.0000097 ↗
6. Lunn D. S. (2013). “Behavior and modeling of infill masonry walls strengthened with FRP using various end anchorage.” Ph.D. thesis North Carolina State Univ. Raleigh NC.
7. 10.1061/(ASCE)CC.1943-5614.000008810.1061/(ASCE)CC.1943-5614.0000088 ↗
8. Lunn D. S. Rizkalla S. H. Maeda S. and Ueda T. (2012). “FRP anchorage systems for infill masonry structures.” Proc. Third Asia-Pacific Conf. on FRP in Structures (APFIS 2012) International Institute for FRP in Construction (IIFC) Kingston ON Canada.
9. Masonry Standards Joint Committee (MSJC). (2011). “Building code requirements for masonry structures.” TMS 402-11/ACI 530-11/ASCE 5-11 The Masonry Society American Concrete Institute and ASCE Boulder CO Farmington Hills MI and Reston VA.