journal article·2011-06

Damage Assessment and Ductility Evaluation of Post Tensioned Beams with Hybrid FRP Tendons

Yujin Liang, Changsen Sun, Farhad Ansari

Publisher page

Abstract

The study presented in this article concentrated on investigating the ductility and characterization of damage in concrete beams post tensioned with hybrid carbon-glass fiber-reinforced polymer (HFRP) composites. The investigation included an approach for design of flexural members with HFRP tendons and characterization of damage, load deformation response, ultimate strength, and failure modes. Direct tensile tests of hybrid FRP rods in a previous study had indicated elastoplastic response, enhanced ductility, and increased strain capacity. In this context, the current study focused on design and fabrication of post tensioned beams using glass or steel rebars for partial prestressing. All the beams were tested in flexure under four-point bending configuration. Results of the study are presented in terms of ductility index and enhanced load-deflection response in comparison with the conventional FRP materials. Damage characterization involved evaluating the specific features of the acoustic emissions for detecting the elastoplastic transition in the hybrid tendons. The method involved use of a high-resolution fiber-optic interferometer for detection and separation of acoustic emissions. By using the time domain response, it was possible to spatially localize the damage at various stages of the loading. Spectral energy of the acoustic emissions facilitated separation of carbon and glass fiber fractures.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Concrete Corrosion and Durability · Structural Behavior of Reinforced Concrete · Structural Health Monitoring Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Research Scientist, Smart Sensor and NDT Lab, Dept. of Civil and Materials Engineering, Univ. of Illinois at Chicago, Chicago, IL 60607.

Visiting Professor, Smart Sensor and NDT Lab, Dept. of Civil and Materials Engineering, Univ. of Illinois at Chicago, Chicago, IL 60607.

Professor and Head, Smart Sensor and NDT Lab, Dept. of Civil and Materials Engineering, Univ. of Illinois at Chicago, Chicago, IL 60607 (corresponding author).

References (34)

Show source-provided references
1. 10.1177/00219983990330190210.1177/002199839903301902 ↗
2. ASTM. (2008). “Standard test method for tensile properties of plastics.” ASTM-D638 West Conshohocken PA.
3. 10.1016/j.engstruct.2008.07.00310.1016/j.engstruct.2008.07.003 ↗
4. 10.1016/S0266-3538(00)00184-610.1016/S0266-3538(00)00184-6 ↗
5. Belarbi A. Chandrashekhara K. and Watkins S. E. (1999). “Performance evaluation of fiber reinforced polymer reinforcing bar featuring ductility and health monitoring capability.” 4th Int. Symp.: Fiber Reinforced Polymer Reinforcement for Reinforced Concrete Structures SP 188 1–12.
6. Burgoyne C. J. · 2001 · 15
7. 10.1617/s11527-006-9162-410.1617/s11527-006-9162-4 ↗
8. Chen H. L. · 1993 · 171
9. 10.1061/(ASCE)1084-0702(2009)14:1(45)10.1061/(ASCE)1084-0702(2009)14:1(45) ↗
10. 10.1002/stc.430007010810.1002/stc.4300070108 ↗
11. Strengthening of concrete beams using innovative ductile fiber-reinforced polymer fabric
12. 10.15554/pcij.01012004.92.10410.15554/pcij.01012004.92.104 ↗
13. 10.1061/40495(302)1010.1061/40495(302)10 ↗
14. 10.1504/IJMPT.2003.00250910.1504/IJMPT.2003.002509 ↗
15. 10.1061/(ASCE)1090-0268(1998)2:1(28)10.1061/(ASCE)1090-0268(1998)2:1(28) ↗
16. 10.1177/073168440403349210.1177/0731684404033492 ↗
17. 10.1504/IJMPT.2004.00499610.1504/IJMPT.2004.004996 ↗
18. 10.1061/(ASCE)1090-0268(2004)8:1(70)10.1061/(ASCE)1090-0268(2004)8:1(70) ↗
19. 10.1016/S0950-0618(00)00036-210.1016/S0950-0618(00)00036-2 ↗
20. Naaman A. E. and Jeong S. E. (1995). “Structural ductility of concrete beams prestressed with FRP tendons.” Proc. 2nd Int. RILEM Symp. (FRPRCS-2): Non-Metallic (FRP) for Concrete Structures Ghent Belgium 379–386.
21. 10.1061/(ASCE)0733-9445(1993)119:11(3344)10.1061/(ASCE)0733-9445(1993)119:11(3344) ↗
22. 10.1016/0950-0618(94)90005-110.1016/0950-0618(94)90005-1 ↗
23. 10.1260/136943301150246210.1260/1369433011502462 ↗
24. Phelan S. R. and Triantafillou T. (1992). “Low cost maglev guide way design using hybrid FRP-reinforced concrete.” Proc. 1st Int. Conf. on High Speed Ground Transportation Systems ASCE New York.
25. 10.1061/(ASCE)CC.1943-5614.000003510.1061/(ASCE)CC.1943-5614.0000035 ↗
26. 10.1007/BF0232314610.1007/BF02323146 ↗
27. 10.1016/S0950-0618(98)00016-610.1016/S0950-0618(98)00016-6 ↗
28. Sanhdars M. A. D. · 2000
29. 10.1016/S0950-0618(97)00036-610.1016/S0950-0618(97)00036-6 ↗
30. Ductile hybrid fiber reinforced plastic reinforcing bar for concrete structures: Design methodology
31. 10.1109/JLT.2004.82446310.1109/JLT.2004.824463 ↗
32. Tamuzs V. and Tepfers R. (1995). “Ductility of non-metallic hybrid fiber composite reinforcement for concrete.” Proc. 2nd Int. RILEM Symp. Ghent Belgium 18–25.
33. 10.1061/(ASCE)1090-0268(1999)3:1(38)10.1061/(ASCE)1090-0268(1999)3:1(38) ↗
34. Tung D. P. and Campbell T. I. (2002). “Ductility of pretensioned concrete beams with hybrid FRP/stainless steel reinforcements.” Proc. Annual Conf.—Canadian Society for Civil Engineering CSCE Montréal Québec Canada 1559–1568.