Deflection Prediction for FRP-Strengthened Concrete Beams
Source abstract
Abstract
Due to increasing popularity of using fiber-reinforced polymer (FRP) for external strengthening of concrete structures, an urgent demand for understanding the structural behavior of FRP-strengthened structures has been emerging. Unlike conventional reinforced concrete (RC) structures, FRP-strengthened members can exhibit additional flexural capacity in the postyielding stage. This makes RC models for predicting deflection inapplicable in case of FRP-strengthened structures. Therefore, some models have been explicitly developed for evaluating deflection of the strengthened structures. However, most existing models are empirically based, verified with limited experimental results, and require in some cases sophisticated calculation procedures. Accordingly, there is still a demand for a rational and more convenient model for predicting deflection of FRP-strengthened beams. In the current paper, Bischoff’s model, originally proposed for RC and FRP reinforced structures, was extended. Consequently, the developed model is applicable to FRP-strengthened concrete beams besides its validity to both RC and FRP reinforced beams. Validation of the model with some available test data confirmed its accuracy.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Assistant Professor, Dept. of Civil Engineering, Qena Faculty of Engineering, South Valley Univ., P.O. Box 83521, Qena, Egypt.
References (17)
Show source-provided references
1. American Concrete Institute (ACI). (2002). “Building code requirements for structural concrete and commentary.” ACI 318-02 ACI 318R-02 Farmington Hills Mich.
2. American Concrete Institute (ACI). (2003). “Guide for the design and construction of concrete reinforced with FRP bars.” ACI 440.1R-03 Farmington Hills Mich.
3. 10.1061/(ASCE)0733-9445(2005)131:5(752)10.1061/(ASCE)0733-9445(2005)131:5(752) ↗
4. Branson D. E. (1965). “Instantaneous and time-dependent deflections of simple and continuous reinforced concrete beams.” Alabama Highway Dept. Bureau of Public Roads HPR Rep. No . 7 Dept. of Civil Engineering and Auburn Research Foundation Auburn Univ. Part 1.
5. Charkas H. Rasheed H. A. and Melhem H. G. (2002). “Simplified load-deflection calculations of FRP strengthened RC beams based on a rigorous approach.” Proc. 15th Engineering Mechanics Conf. ASCE New York.
6. CSA. (2004). “Design of concrete structures.” CSA standard A23.3-04 Rexdale Toronto.
7. Dolan C. W. (1989). “Prestressed concrete using Kevlar reinforced tendons.” Ph.D. thesis Cornell Univ. New York.
8. Deflection of reinforced concrete beams strengthened with fiber-reinforced polymer (FRP) plates
9. Gao D. Benmokrane B. and Masmoudi R. (1998). “A calculating method of flexural properties of FRP-reinforced concrete beam: Part 1: Crack width and deflection.” Technical Rep. Dept. of Civil Engineering Univ. of Sherbrooke Sherbrooke Québec.
10. 10.1061/(ASCE)0733-9445(2006)132:8(1328)10.1061/(ASCE)0733-9445(2006)132:8(1328) ↗
11. 10.1061/(ASCE)1090-0268(2008)12:2(168)10.1061/(ASCE)1090-0268(2008)12:2(168) ↗
12. 10.1061/(ASCE)1090-0268(2008)12:3(284)10.1061/(ASCE)1090-0268(2008)12:3(284) ↗
13. Said H. O. and Wu Z. S. (2008b). “IC debonding in FRP-strengthened structures: Experimental study.” Proc. 4th Int. Conf. on Composites in Civil Engineering (CD-ROM) CICE Zurich Switzerland.
14. 10.1016/S0950-0618(03)00043-610.1016/S0950-0618(03)00043-6 ↗
15. Flexural behavior of concrete beams reinforced with glass fiber-reinforced polymer bars
16. Strengthening effects and effective anchorage method for flexural members with externally bonded CFRP plates
17. 10.2208/jsceje.63.62010.2208/jsceje.63.620 ↗