Behavior of Prestressed Hollow-Core Slabs Strengthened in Flexure with Near-Surface Mounted Carbon Fiber-Reinforced Polymer Reinforcement
Source abstract
Abstract
Flexural strengthening of reinforced concrete using near-surface mounted (NSM) fiber-reinforced polymer (FRP) composites is a widely studied topic, and a promising technology. However, overlooked applications such as prestressed concrete and one-way slabs require further experimental investigation and theoretical refinement in order to develop comprehensive design guidelines. This paper investigates the behavior of prestressed hollow-core slabs strengthened in flexure with NSM carbon FRP strip reinforcement. Seven full-scale simply supported slab specimens were tested to failure under two-point monotonic load configuration. Experimental variables included two different internal prestressing reinforcement ratios, and three different NSM strengthening reinforcement ratios. This paper examines cracking behavior and modes of failure, load-strain relationships, deflections, and strengthened capacities. Also, a comparison between experimental results and theoretical predictions by relevant Canadian and American standards or guidelines is presented.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Structural Engineer, Stantec Inc., Winnipeg, MB, Canada R3B 2B9.
Postdoctoral Fellow, Dept. of Civil Engineering, Univ. of Manitoba, Winnipeg, MB, Canada R3T 5V6.
Professor and Canada Research Chair in Durability and Modernization of Civil Structures, Dept. of Civil Engineering, Univ. of Manitoba, Winnipeg, MB, Canada R3T 5V6 (corresponding author).
References (19)
Show source-provided references
1. ACI (American Concrete Institute). (2008). “Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures.” ACI 440.2R-08 Detroit.
2. ACI (American Concrete Institute). (2014). “Building code requirements for reinforced concrete.” ACI 318-14 Detroit.
3. 10.1016/j.conbuildmat.2009.03.00510.1016/j.conbuildmat.2009.03.005 ↗
4. Strength and ductility of reinforced concrete beams externally reinforced with carbon fiber fabric
5. 10.1061/(ASCE)1090-0268(2008)12:2(149)10.1061/(ASCE)1090-0268(2008)12:2(149) ↗
6. CPCI (Canadian Precast/Prestressed Concrete Institute) · 2007
7. CSA (Canadian Standards Association). (2009). “Concrete materials and methods of concrete construction/test methods and standard practices for concrete.” CSA A23.1-09/A23.2-09 (R2014) Rexdale ON Canada 647.
8. CSA (Canadian Standards Association). (2012). “Design and construction of building components with fiber-reinforced polymers.” CAN/CSA-S806-12 Toronto 187.
9. CSA (Canadian Standards Association). (2014). “Code for the design of concrete structures for buildings.” CSA/A23.3-14 Rexdale ON Canada.
10. Bond between near-surface mounted fiber-reinforced polymer rods and concrete in structural strengthening
11. 10.1016/j.compositesb.2006.08.00310.1016/j.compositesb.2006.08.003 ↗
12. 10.1016/j.compstruct.2009.08.01510.1016/j.compstruct.2009.08.015 ↗
13. Near-surface-mounted fiber-reinforced polymer reinforcements for flexural strengthening of concrete structures
14. 10.1061/(ASCE)CC.1943-5614.000022510.1061/(ASCE)CC.1943-5614.0000225 ↗
15. Bond mechanism of near-surface-mounted fiber-reinforced polymer bars for flexural strengthening of concrete structures
16. 10.1139/l06-04010.1139/l06-040 ↗
17. 10.1016/j.compositesb.2012.01.07110.1016/j.compositesb.2012.01.071 ↗
18. 10.1061/(ASCE)1090-0268(2006)10:2(92)10.1061/(ASCE)1090-0268(2006)10:2(92) ↗
19. Flexural behavior of concrete beams strengthened with near-surface-mounted CFRP strips