Chemical Resistance and Mechanical Properties of Glass Fiber–Reinforced Plastic Pipes for Oil, Gas, and Power-Plant Applications
Source abstract
Abstract
Glass fiber–reinforced plastic (GFRP) composite pipes are used in many diverse applications, including oil, gas, and power plants. These pipes are subjected to various harsh service conditions during their service life. The evaluation of mechanical properties and chemical resistance of these pipes is essential to assess their long-term performance in specific applications. The results of a study to evaluate the chemical resistance and mechanical properties of GFRP pipes for application in oil and gas plants are presented in this paper. Pipe specimens were preconditioned by filling them with 7.5% HCl, 8% H2SO4, and a mixture of 2% NaOH and 2% KMnO4 solutions maintained at 63°C. The preconditioned and fresh pipe specimens were exposed to clean and oily water [a mixture of 10% toluene, 10% kerosene, and 80% brine water (30 g/L NaCl)] maintained at 93°C and 1.5×106 Pa (15 bar) pressure for 1,000 h. The fresh, preconditioned, and exposed pipe specimens were tested to evaluate their axial and hoop tensile strength, water absorption, and loss on ignition. The experimental results did not exhibit major change in the properties of evaluated pipes owing to exposure to clean and oily water at high temperature and pressure. There was minimal or no loss in the axial and hoop strength of the preconditioned or exposed pipes. The absorption and loss of ignition did not increase significantly both due to pre-conditioning and evaluated exposure conditions. The results indicate that GFRP pipes are suitable for application in the oil and gas industry.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Mechanical Behavior of Composites · Structural Integrity and Reliability Analysis · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Associate Professor, Dept. of Mechanical Engineering, King Fahd Univ. of Petroleum and Minerals, P.O. Box 135, Dhahran 31261, Saudi Arabia.
Senior Research Engineer (Professor), Center for Engineering Research, Research Institute, King Fahd Univ. of Petroleum and Minerals, P.O. Box 442, Dhahran 31261, Saudi Arabia.
Senior Engineer, Center for Engineering Research, Research Institute, King Fahd Univ. of Petroleum and Minerals, P.O. Box 1331, Dhahran 31261, Saudi Arabia (corresponding author).
References (30)
Show source-provided references
1. The effects of weathering on mechanical properties of glass fiber reinforced plastics (GRP) materials
2. Effect of six months exposure to atmospheric conditions on the mechanical properties of GRP
3. 10.1177/002199831037793310.1177/0021998310377933 ↗
4. ASTM. (2000a). “Standard practice for classifying visual defects in glass-reinforced plastic laminate parts.” ASTM D2563 Philadelphia PA.
5. ASTM. (2000b). “Standard test method for apparent tensile strength of ring or tubular plastic and reinforced plastic by split disk method.” ASTM D2290 Philadelphia PA.
6. ASTM. (2000c). “Standard test method for longitudinal tensile properties of fiberglass (glass fiber reinforced thermosetting resin) pipe and tube.” ASTM D2105 Philadelphia PA.
7. ASTM. (2001). “Standard test method for ignition loss of cured reinforced resins.” ASTM D2584 Philadelphia PA.
8. ASTM. (2002). “Standard test method for water absorption of plastics.” ASTM D570 Philadelphia PA.
9. 10.1016/0010-4361(91)90002-X10.1016/0010-4361(91)90002-X ↗
10. 10.2516/ogst:199500610.2516/ogst:1995006 ↗
11. Correia J. R. Cabral-Fonseca S. Branco F. A. Ferreira J. G. Eusébio M. I. and Rodrigues M. P. (2005). “Durability of glass fibre reinforced polyester (GFRP) pultruded profiles used in civil engineering applications.” 3rd Int. Conf. Composites in Construction Claude Bernad Lyon 1 Univ. Lyon France.
12. 10.1016/j.compscitech.2004.01.01710.1016/j.compscitech.2004.01.017 ↗
13. 10.1177/07316840077267851810.1177/073168400772678518 ↗
14. 10.1177/00219983000340100210.1177/002199830003401002 ↗
15. 10.1016/S0142-9418(03)00075-810.1016/S0142-9418(03)00075-8 ↗
16. On the prediction of long-term creep-failure of GRP pipes in aqueous environment10.1002/pc.20891 ↗
17. 10.1177/00219983980320100410.1177/002199839803201004 ↗
18. Jones F. R. · 1999
19. 10.1177/002199830203601797710.1177/0021998302036017977 ↗
20. 10.1061/(ASCE)1090-0268(2000)4:4(191)10.1061/(ASCE)1090-0268(2000)4:4(191) ↗
21. 10.1016/S0266-3538(00)00244-X10.1016/S0266-3538(00)00244-X ↗
22. Morii T. Hamada T. H. Ikuta N. Desaeger M. and Verpoest I. (1995). “Effect of saline treated fiber on impact properties of hydrothermal aged glass fabric/epoxy laminates.” SAMPE Technical Conf. Vol. 27 Society for the Advancement of Material and Process Engineering 1048–1058.
23. 10.1061/(ASCE)1090-0268(2002)6:1(21)10.1061/(ASCE)1090-0268(2002)6:1(21) ↗
24. 10.3323/jcorr1991.43.34010.3323/jcorr1991.43.340 ↗
25. 10.1016/j.engfailanal.2012.07.02510.1016/j.engfailanal.2012.07.025 ↗
26. 10.1016/0927-796X(94)90002-710.1016/0927-796X(94)90002-7 ↗
27. 10.1016/B0-08-042993-9/00181-910.1016/B0-08-042993-9/00181-9 ↗
28. Water absorption of resins and composites: Diffusion in carbon and glass reinforced epoxies
29. 10.1016/j.polymertesting.2005.11.01010.1016/j.polymertesting.2005.11.010 ↗
30. Zhang S. and Karbhari V. M. (1999). “Effects of alkaline environments on the durability of E-glass fiber composites for use in civil infrastructure.” Proc. American Society of Composites Technomic Lancaster PA 12–20.