Comparison of Roles of FRP Sheets, Stirrups, and Steel Fibers in Confining Bond Critical Regions
Source abstract
Abstract
Based on experimental data of tension lap splices confined with fiber reinforced polymer (FRP) sheets in normal and high strength concrete (HSC) specimens, a new FRP confinement parameter, Ktr,f, was recommended. It accounts for the increase in bond strength due to the presence of FRP sheets. In this paper, a correlation is presented between the confining effects of FRP flexible sheets, transverse reinforcement, and steel fibers to improve the bond capacity and ductility of the mode of failure of tension lap splices. The correlation is based on research programs conducted at the American University of Beirut in recent years using identical specimens except for the confinement method used: FRP sheets, transverse steel stirrups, or steel fibers. Other variables included the amount of confinement provided and concrete strength. Analysis of test results indicated that an equivalent improvement in bond strength of tension lap splices in normal and high strength concrete specimens is provided by an amount of FRP sheets corresponding to a Ktr,f value of 2.5, or an amount of transverse reinforcement corresponding to Ktr of 1.0db. For HSC specimens, an amount of steel fibers corresponding to a volume fraction of 1% would provide an equivalent improvement in bond strength.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Professor, Dept. of Civil and Environmental Engineering, American Univ. of Beirut, P.O. Box 11-0236, Riad El Solh 1107 2020, Beirut, Lebanon (corresponding author). E-mail: bhamad@aub.edu.lb
Graduate Student, Dept. of Civil Engineering, Univ. of Waterloo, Canada.
References (11)
Show source-provided references
1. ACI Committee 318. (2005). “Building code requirements for reinforced concrete and commentary.” ACI 318-05/ACI 318R-05 Farmington Hills Mich.
2. Behavior of lap-spliced reinforcing bars embedded in high strength concrete
3. Bond performance of reinforcing bars embedded in high strength concrete
4. Development length criteria for conventional and high relative area reinforcing bars
5. Effect of steel fiber reinforcement on bond strength of tension lap splices in high strength concrete
6. 10.1617/1378610.1617/13786 ↗
7. Correlation between roles of transverse reinforcement and steel fibers in confining tension lap splices in high strength concrete.
8. 10.1061/(ASCE)1090-0268(2004)8:3(248)10.1061/(ASCE)1090-0268(2004)8:3(248) ↗
9. 10.1061/(ASCE)1090-0268(2004)8:1(14)10.1061/(ASCE)1090-0268(2004)8:1(14) ↗
10. Experimental and analytical evaluation of the bond strength of reinforcement in FRP wrapped HSC beams
11. Salwan B. R. (2003). “Behavior of bond critical regions wrapped with FRP sheets in normal strength concrete.” Masters thesis American Univ. of Beirut Beirut Lebanon.