journal article·2017-06Open access

Pull-Out Behavior of CFRP Single-Strap Ground Anchors

Haifeng Fan, Anastasios P. Vassilopoulos, Thomas Keller

Abstract

Pull-out experiments were performed on four carbon fiber–reinforced polymer (CFRP) ground anchors simulating their applications in rock and soil. The CFRP tendons used in these anchors comprise a single-strap end on both ground and air sides. On the ground side, the single-strap end is embedded in a prefabricated cylinder of high-strength grout that fits into the borehole. In rock applications, the ground-side anchor can be used without additional confinement, while in the case of soil, an additional CFRP confinement ring is needed to prevent premature grout failure in the strap region. The load transfer from the strap to the grout cylinder occurs progressively; approximately 50% of the load is transferred at the semicircular strap end, while the remaining 50% is transferred at the curved transition from the strap to the rod segment of the free length.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Ph.D. Student, Composite Construction Laboratory, Ecole Polytechnique Fédérale de Lausanne, Station 16, CH-1015 Lausanne, Switzerland.

Senior Scientist, Composite Construction Laboratory, Ecole Polytechnique Fédérale de Lausanne, Station 16, CH-1015 Lausanne, Switzerland.

Professor, Composite Construction Laboratory, Ecole Polytechnique Fédérale de Lausanne, Station 16, CH-1015 Lausanne, Switzerland (corresponding author).

References (20)

Show source-provided references
1. Aoyagi K. Yoshida T. Yamazai Y. and Maruyama K. (1996). “NM (new material) ground anchor system.” Proc. 2nd Int. Conf. on Advanced Composite Materials in Bridges and Structures Canadian Society for Civil Engineering Montréal 727–734.
2. Aramid and carbon fibre-reinforced plastic prestressed ground anchors and their field applications10.1139/cjce-24-6-968 ↗
3. CEN (European Committee for Standardization). (2013). “Execution of special geotechnical work–ground anchor.” BS EN 1537:2013 Brussels Belgium.
4. 10.1177/002199831349151410.1177/0021998313491514 ↗
5. 10.1016/j.compositesb.2016.01.04910.1016/j.compositesb.2016.01.049 ↗
6. Huster U. Broennimann R. and Winistörfer A. (2008). “Strengthening of a historical roof structure with CFRP-straps.” Proc. 4th Int. Conf. on FRP Composites in Civil Engineering EMPA Zurich Switzerland.
7. 10.1061/(ASCE)0733-9399(1997)123:1(25)10.1061/(ASCE)0733-9399(1997)123:1(25) ↗
8. Carbon fiber-reinforced polymer punching reinforcement and strengthening of concrete flat slabs
9. 10.1061/(ASCE)0733-9445(2002)128:5(612)10.1061/(ASCE)0733-9445(2002)128:5(612) ↗
10. 10.1007/BF0118567610.1007/BF01185676 ↗
11. Test method for measurement of the strain-softening behaviour of concrete under uniaxial compression
12. 10.1061/(ASCE)0733-9445(1998)124:9(1025)10.1061/(ASCE)0733-9445(1998)124:9(1025) ↗
13. 10.1061/(ASCE)0733-9445(1998)124:9(1025)10.1061/(ASCE)0733-9445(1998)124:9(1025) ↗
14. 10.1016/j.conbuildmat.2011.11.04910.1016/j.conbuildmat.2011.11.049 ↗
15. Tokyo Rope Co. Ltd. (2016). “Summary of application projects.” ⟨https://isabou.net/sponsor/nm-anchor/sekou.asp⟩ (May 2 2016).
16. 10.1007/BF0252477710.1007/BF02524777 ↗
17. 10.1061/(ASCE)CC.1943-5614.000056310.1061/(ASCE)CC.1943-5614.0000563 ↗
18. Winistoerfer A. U. (1999). “Development of non-laminated advanced composite straps for civil engineering applications.” Univ. of Warwick Coventry U.K.
19. 10.1002/978047017278010.1002/9780470172780 ↗
20. Experimental study of a large-scale ground anchor system with FRP tendon and RPC grout medium