journal article·2002-11

Flexural Creep Tests and Modeling of Concrete-Filled Fiber Reinforced Polymer Tubes

Wassim Naguib, Amir Mirmiran

Publisher page

Abstract

An experimental and analytical investigation was made into the flexural creep behavior of concrete-filled fiber reinforced polymer (FRP) tubes (CFFT). While creep effects reduce the flexural stiffness of CFFT specimens, ultimate strength is not significantly altered. The slow rate of loading and short-term creep at 70% of static capacity may cause premature rupture of the tube. Fiber analysis of CFFT beam-columns by discretizing the section into filled and hollow FRP tubes can adequately simulate the flexural creep behavior. Isochronous sustained stress-creep strain curves are used as a constitutive nonlinear relationship for creep analysis in flexure. Creep deflection of CFFT beam-columns is much less than that of CFFT beams, mainly because axial compressive loads tend to retard the cracking of concrete and tensile creep of FRP. The stiffness ratio of FRP tubes with respect to the concrete core has a pronounced effect on the creep deflection of CFFT beam-columns. As the stiffness ratio increases, creep deflection decreases. However, there exists a threshold beyond which stiffer tubes do not provide additional benefit. CFFT beam-columns under high levels of sustained axial loads have a lower creep rupture life expectancy, mainly because failure moments under large axial forces are lower. The creep rupture life expectancy of CFFT beam-columns with diameter-to-thickness ratios of 40 or less is at least 50 years at transverse loads as high as 60% of the static capacity.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Structural Engineer, Simpson Gumpertz & Heger, Inc., 222 Sutter St., Suite 300, San Francisco, CA 94108; formerly, PhD Student, Dept. of Civil and Environmental Engineering, Univ. of Cincinnati, Cincinnati, OH 45221.

Professor, Dept. of Civil Engineering, North Carolina State Univ., Raleigh, NC 27695-7533.

References (17)

Show source-provided references
1. American Concrete Institute (ACI) Committee 209. (1992). “Prediction of creep shrinkage and temperature effects in concrete structures.” SP-70 Detroit.
2. Double power law for basic creep of concrete.
3. Bazant Z. P. and Wittmann F. H. (1980). Creep and shrinkage in concrete structures Wiley New York.
4. Bresler B. and Selna L. (1964). “Analysis of time-dependent behavior of reinforced concrete structures.” ACI special publication SP-9 Symp. on Creep of Concrete Vol. 5 American Concrete Institute Detroit 115–128.
5. 10.1061/(ASCE)0733-9445(1995)121:7(1079)10.1061/(ASCE)0733-9445(1995)121:7(1079) ↗
6. di Scalea F. L. Karbhari V. M. and Seible F. (2000). “I-5/Gilman advanced technology bridge project ” Proc. SPIE International Society for Optical Engineering Bellingham Wash. Vol. 3988 10–17.10.1016/S1471-3918(00)80021-0 ↗
7. Findley W. N.(1960). “Mechanism and mechanics of creep of plastics.” SPE J. 57–65.
8. Findley W. N. Lai J. S. and Onaran K. (1976). Creep and relaxation of nonlinear viscoelastic materials Dover New York.
9. 10.1016/S0045-7949(99)00178-910.1016/S0045-7949(99)00178-9 ↗
10. Principles and analysis of concrete-filled composite tubes.
11. Mirmiran A. and Shahawy M. (2001). “Drivability of composite piles.” Proc. Annual Meeting (CD-Rom) Transportation Research Board Washington D.C.
12. Morino S. Kswaguchi J. and Cao Z. S. (1997). “Creep behavior of concrete-filled steel tubular members.” Proc. Engineering Foundation Conf. on Composite Construction in Steel and Concrete III ASCE New York 514–525.
13. Time-dependent behavior of FRP-confined concrete columns.
14. 10.1061/(ASCE)0733-9445(1994)120:3(1016)10.1061/(ASCE)0733-9445(1994)120:3(1016) ↗
15. 10.1061/(ASCE)0733-9445(1998)124:9(1025)10.1061/(ASCE)0733-9445(1998)124:9(1025) ↗
16. Terrey P. J. Bradford M. A. and Gilbert R. I. (1994). “Creep and shrinkage in concrete-filled steel tubes.” Tubular structures VI Grundy Holgate and Wong eds. Balkema Rotterdam The Netherlands 293–298.10.1201/9780203735015-43 ↗
17. 10.1177/00219983710050010610.1177/002199837100500106 ↗