Shape Effects on the Behavior of Hybrid FRP–Strengthened Rectangular RC Columns under Axial Compression
Source abstract
Abstract
Confinement with external bonding (EB) of fiber-reinforced polymer (FRP) composites is effective for improving the performance of reinforced concrete (RC) columns under axial compression. However, EB confinement is less effective for sections with a side aspect (width/depth) ratio of more than 2. Thus, a hybrid FRP strengthening technique that combines the advantages of EB and near-surface mounting (NSM) of carbon FRP (CFRP) laminates was explored. Twenty-four rectangular RC columns of different aspect ratios (b/d = 1.0, 2.0, and 3.0) were strengthened and tested under axial compression to investigate the effect of shape on the efficiency of hybrid FRP strengthening. Two specimens each for control, EB confinement, NSM, and hybrid FRP strengthening were tested at each aspect ratio to decouple the interaction effects in hybrid FRP strengthening. A three-dimensional nonlinear finite-element (FE) analysis was conducted using commercially available software. Three-dimensional FE models of different RC columns of varying aspect ratios were created with EB confinement, NSM, and hybrid FRP strengthening and were analyzed. FE models were validated with test results and subsequently used for parametric study. A detailed parametric investigation on the effect of the hybrid combination of a varying NSM ratio (0.4%–1.6%) and a constant EB confinement ratio was studied. Both experimental and FE results indicated that the efficiency of confinement reduces with an increase in the aspect ratio. The hybrid FRP technique was effective in improving both the axial strength and ductility of columns with large aspect ratios.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Research Scholar, Dept. of Civil Engineering, Indian Institute of Technology Hyderabad, Kandi, Sangareddy, Telangana 502285, India. ORCID: .
Professor, Dept. of Civil Engineering, Indian Institute of Technology Hyderabad, Kandi, Sangareddy, Telangana 502285, India (corresponding author). ORCID: .
References (59)
Show source-provided references
1. ABAQUS. 2014. Abaqus v. 6.14-2 analysis user’s guide—Online documentation. Providence, RI: Dassault Systemes Simulia Corp.
2. 10.1016/j.compstruct.2019.11171610.1016/j.compstruct.2019.111716 ↗
3. 10.1061/(ASCE)CC.1943-5614.000027810.1061/(ASCE)CC.1943-5614.0000278 ↗
4. ACI (American Concrete Institute). 2017. Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures. ACI 440.2R-17. Farmington Hills, MI: ACI.
5. Adebar, P., and A. Lorzadeh. 2012. “Compression failure of thin concrete walls.” In 15 WCEE, 1–10. Red Hook, NY: Curran Associates, Inc. http://toc.proceedings.com/24574webtoc.pdf/.
6. 10.1016/j.compositesb.2006.06.01910.1016/j.compositesb.2006.06.019 ↗
7. 10.1016/j.conbuildmat.2014.04.04710.1016/j.conbuildmat.2014.04.047 ↗
8. ASTM. 2017. Standard test method for tensile properties of polymer matrix composite materials. ASTM D3039/D3039M-17. West Conshohocken, PA: ASTM.
9. ASTM. 2020. Standard test method for open-hole compressive strength of polymer matrix composite laminates. ASTM D6484/D6484M-20. West Conshohocken, PA: ASTM.
10. ASTM. 2021. Standard test method for compressive strength of cylindrical concrete specimens. ASTM C39/C39M-21. West Conshohocken, PA: ASTM.
11. 10.1016/j.engstruct.2008.05.01910.1016/j.engstruct.2008.05.019 ↗
12. BIS (Bureau of Indian Standards). 1987. Methods of test for chemical resistant mortars. Part I silicate type and resin type. IS: 4456 (Part I)-87. New Delhi, India: BIS.
13. BIS (Bureau of Indian Standards). 2004. Methods of tests for strength of concrete. IS: 516-04. New Delhi, India: BIS.
14. BIS (Bureau of Indian Standards). 2009. Indian standard guidelines for concrete mix design proportioning. IS: 10262-09. New Delhi, India: BIS.
15. BIS (Bureau of Indian Standards). 2018. Metallic materials—Tensile testing at ambient temperature. IS: 1608 (Part 1)-18. New Delhi, India: Bureau of Indian Standards.
16. Bisby, L. A., A. J. Dent, and M. F. Green. 2005. “Comparison of confinement models for FRP wrapped concrete.” ACI Struct. J. 102 (1): 62–72.
17. 10.1016/S0958-9465(01)00048-810.1016/S0958-9465(01)00048-8 ↗
18. 10.1061/(ASCE)0733-9445(1994)120:8(2358)10.1061/(ASCE)0733-9445(1994)120:8(2358) ↗
19. 10.3390/fib710009010.3390/fib7100090 ↗
20. 10.14359/5171087710.14359/51710877 ↗
21. 10.1061/(ASCE)BE.1943-5592.000142010.1061/(ASCE)BE.1943-5592.0001420 ↗
22. 10.1016/j.compstruct.2017.05.03310.1016/j.compstruct.2017.05.033 ↗
23. 10.1016/j.compstruct.2017.09.10910.1016/j.compstruct.2017.09.109 ↗
24. 10.1061/(ASCE)CC.1943-5614.000095210.1061/(ASCE)CC.1943-5614.0000952 ↗
25. 10.1260/1369-4332.16.4.59310.1260/1369-4332.16.4.593 ↗
26. 10.1061/(ASCE)CC.1943-5614.000015210.1061/(ASCE)CC.1943-5614.0000152 ↗
27. 10.1016/j.compstruct.2016.07.01410.1016/j.compstruct.2016.07.014 ↗
28. 10.1016/j.engstruct.2021.11230310.1016/j.engstruct.2021.112303 ↗
29. 10.1016/j.compstruct.2005.01.01810.1016/j.compstruct.2005.01.018 ↗
30. 10.1061/(ASCE)CC.1943-5614.000021710.1061/(ASCE)CC.1943-5614.0000217 ↗
31. 10.1016/j.compositesb.2018.09.04510.1016/j.compositesb.2018.09.045 ↗
32. 10.1061/(ASCE)CC.1943-5614.000105210.1061/(ASCE)CC.1943-5614.0001052 ↗
33. 10.1016/j.engstruct.2007.01.01010.1016/j.engstruct.2007.01.010 ↗
34. Khorramian, K., and P. Sadeghian. 2018. “Strengthening slender circular concrete columns with a novel hybrid FRP system.” In Proc., 6th Int. Structural Specialty Conf. 2018, Held as Part of the Canadian Society for Civil Engineering Annual Conf. 2018, 756–766. Quebec, Canada: Canadian Society of Civil Engineers.
35. 10.1016/S0950-0618(03)00045-X10.1016/S0950-0618(03)00045-X ↗
36. 10.1177/073168440303542910.1177/0731684403035429 ↗
37. 10.1061/(ASCE)0733-9445(1988)114:8(1804)10.1061/(ASCE)0733-9445(1988)114:8(1804) ↗
38. 10.1061/(ASCE)0733-9445(2006)132:1(123)10.1061/(ASCE)0733-9445(2006)132:1(123) ↗
39. 10.1061/(ASCE)0733-9445(1997)123:5(583)10.1061/(ASCE)0733-9445(1997)123:5(583) ↗
40. 10.1061/(ASCE)1090-0268(1998)2:4(175)10.1061/(ASCE)1090-0268(1998)2:4(175) ↗
41. 10.1061/(ASCE)CC.1943-5614.000054510.1061/(ASCE)CC.1943-5614.0000545 ↗
42. Olivova, K., and J. Bilcik. 2009. “Strengthening of concrete columns with CFRP.” Slovak J. Civ. Eng. 1: 1–9.
43. 10.1061/(ASCE)CC.1943-5614.000035710.1061/(ASCE)CC.1943-5614.0000357 ↗
44. 10.1016/j.compstruct.2004.02.00210.1016/j.compstruct.2004.02.002 ↗
45. 10.1016/j.compstruct.2005.02.01910.1016/j.compstruct.2005.02.019 ↗
46. Pessiki, S., and A. Pieroni. 1997. “Axial load behavior of large scale spirally reinforced high strength concrete columns.” ACI Struct. J. 94 (3): 304–314.
47. 10.1016/j.compositesb.2006.01.00510.1016/j.compositesb.2006.01.005 ↗
48. 10.1016/j.compstruct.2019.11120710.1016/j.compstruct.2019.111207 ↗
49. 10.1061/(ASCE)1090-0268(1999)3:3(143)10.1061/(ASCE)1090-0268(1999)3:3(143) ↗
50. 10.1061/(ASCE)CC.1943-5614.000005110.1061/(ASCE)CC.1943-5614.0000051 ↗
51. 10.1617/s11527-015-0526-510.1617/s11527-015-0526-5 ↗
52. 10.1016/j.istruc.2018.02.00710.1016/j.istruc.2018.02.007 ↗
53. 10.1016/j.conbuildmat.2018.03.13110.1016/j.conbuildmat.2018.03.131 ↗
54. 10.1016/j.engstruct.2007.04.01610.1016/j.engstruct.2007.04.016 ↗
55. 10.1061/(ASCE)1090-0268(2009)13:2(125)10.1061/(ASCE)1090-0268(2009)13:2(125) ↗
56. 10.1016/j.compstruct.2012.08.02110.1016/j.compstruct.2012.08.021 ↗
57. 10.1016/j.engstruct.2009.08.01210.1016/j.engstruct.2009.08.012 ↗
58. Yeh, F., and K. Chang. 2004. “Size and shape effect on FRP confinements for rectangular concrete columns.” In Proc., 13th World Conf. on Earthquake Engineering, No. 657, 1–15. Vancouver, BC, Canada: 13 WCEE Secretariat.
59. 10.1061/(ASCE)CC.1943-5614.000112910.1061/(ASCE)CC.1943-5614.0001129 ↗