Compressive Performance of Partially CFRP-Confined Square Seawater–Sea Sand Concrete Columns with Internal Epoxy-Coated Reinforcement
Source abstract
Abstract
This study first presents an experimental investigation on the compressive behavior of carbon fiber–reinforced polymer (CFRP)-confined square seawater–sea sand concrete (SSC) columns with embedded epoxy-coated reinforcement (ECR). Thirty-three columns were tested to explore the influence of several parameters, including clear spacing ratios, FRP wrapping schemes, FRP volumetric ratios, and internal steel reinforcement ratios. Test results reveal that the location of CFRP strips with respect to the steel hoops has a significant impact on the mechanical behavior of specimens, especially for the deformation capacity. Furthermore, more obvious improvements of strength and ductility are detected for the reinforced columns with smaller clear spacing ratios and higher volumetric ratios of FRP wraps. In specific, the maximum enhancements of load capacity and ductility index for the reinforced SSC specimens with two-layer CFRP strips are 11.8% and 92.9%, respectively, while the improvements increase to 15.6% and 189.2% when the thickness of CFRP jackets doubles. A regression-based stress–strain model is developed to evaluate the ultimate conditions of FRP partially wrapped concrete columns, and a better agreement can be achieved by the developed model compared with other existing models. Finally, a simple expression is also proposed based on the experimental observations, which can accurately predict the load capacity of plain and reinforced concrete columns wrapped with FRP strips.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Ph.D. Candidate, State Key Laboratory of Coastal and Offshore Engineering, Dalian Univ. of Technology, Dalian 116024, China.
Professor, State Key Laboratory of Coastal and Offshore Engineering, Dalian Univ. of Technology, Dalian 116024, China.
Professor, State Key Laboratory of Coastal and Offshore Engineering, Dalian Univ. of Technology, Dalian 116024, China. (corresponding author).
References (59)
Show source-provided references
1. Al-Amoudi, O. S. B., M. Maslehuddin, and M. Ibrahim. 2004. “Long-term performance of fusion-bonded epoxy-coated steel bars in chloride-contaminated concrete.” ACI Mater. J. 101 (4): 303–309.
2. ASTM. 2017. Standard test method for tensile properties of polymer matrix composite materials. ASTM D3039/D3039 M-17. West Conshohocken, PA: ASTM.
3. ASTM. 2020. Standard test method for compressive strength of cylindrical concrete specimens. ASTM C39/C39 M-20. West Conshohocken, PA: ASTM.
4. 10.1016/j.compositesb.2006.09.00410.1016/j.compositesb.2006.09.004 ↗
5. 10.1080/13287982.2019.165921310.1080/13287982.2019.1659213 ↗
6. 10.1016/j.conbuildmat.2016.04.05210.1016/j.conbuildmat.2016.04.052 ↗
7. 10.1016/j.engstruct.2016.11.05210.1016/j.engstruct.2016.11.052 ↗
8. 10.1016/S0008-8846(01)00487-210.1016/S0008-8846(01)00487-2 ↗
9. 10.1061/(ASCE)1084-0702(2005)10:3(255)10.1061/(ASCE)1084-0702(2005)10:3(255) ↗
10. fib (International Federation for Structural Concrete). 2001. Externally bonded FRP reinformfrftcement for RC structures. Technical Rep. Bulletin 14. Lausanne, Switzerland: fib.
11. GAQSIQ (General Administration of Quality Supervision, Inspection and Quarantine). 2010. Metallic materials—Tensile testing—Part 1: Method of test at room temperature. [In Chinese.] GB/T 228.1-2010. Beijing: China Architecture and Building Press.
12. 10.3390/s1812411810.3390/s18124118 ↗
13. Harajli, M. H., B. S. Hamad, and A. A. Rteil. 2004. “Effect of confinement on bond strength between steel bars and concrete.” ACI Struct. J. 101 (5): 595–603.
14. 10.1061/(ASCE)0899-1561(2008)20:2(169)10.1061/(ASCE)0899-1561(2008)20:2(169) ↗
15. 10.1016/j.istruc.2019.12.02010.1016/j.istruc.2019.12.020 ↗
16. 10.1061/(ASCE)CC.1943-5614.000086010.1061/(ASCE)CC.1943-5614.0000860 ↗
17. 10.1061/(ASCE)1090-0268(2003)7:3(238)10.1061/(ASCE)1090-0268(2003)7:3(238) ↗
18. 10.1016/S0950-0618(03)00045-X10.1016/S0950-0618(03)00045-X ↗
19. 10.1177/073168440303542910.1177/0731684403035429 ↗
20. 10.1016/j.compstruct.2021.11358910.1016/j.compstruct.2021.113589 ↗
21. 10.1016/j.conbuildmat.2018.10.05910.1016/j.conbuildmat.2018.10.059 ↗
22. 10.1016/j.conbuildmat.2019.04.07710.1016/j.conbuildmat.2019.04.077 ↗
23. Luca, B., E. Bernhard, P. Pietro, and P. Rob. 2004. Corrosion of steel in concrete: Prevention, diagnosis, repair. Hoboken, NJ: Wiley.
24. 10.1016/j.istruc.2018.06.00710.1016/j.istruc.2018.06.007 ↗
25. 10.1061/(ASCE)0733-9445(1988)114:8(1804)10.1061/(ASCE)0733-9445(1988)114:8(1804) ↗
26. 10.1016/j.cemconres.2003.09.02010.1016/j.cemconres.2003.09.020 ↗
27. MOHURD (Ministry of Housing and Urban-Rural Development). 2010a. Code for design of concrete structures. [In Chinese.] GB50010-2010. Beijing: China Architecture and Building Press.
28. MOHURD (Ministry of Housing and Urban-Rural Development). 2010b. Technical code for infrastructure application of FRP composites. [In Chinese.] GB50608-2010. Beijing: China Planning Press.
29. 10.1016/j.oceaneng.2020.10735010.1016/j.oceaneng.2020.107350 ↗
30. 10.1061/(ASCE)1090-0268(2001)5:1(3)10.1061/(ASCE)1090-0268(2001)5:1(3) ↗
31. Park, R. 1988. “State of the art report-ductility evaluation from laboratory and analytical testing.” In Proc., 9th World Conf. on Earthquake Engineering, 605–616. Tokyo: Japan Association for Earthquake Disaster Prevention.
32. 10.1061/(ASCE)CC.1943-5614.000012710.1061/(ASCE)CC.1943-5614.0000127 ↗
33. 10.1016/0008-8846(73)90096-310.1016/0008-8846(73)90096-3 ↗
34. 10.1016/j.engstruct.2020.11102710.1016/j.engstruct.2020.111027 ↗
35. 10.1617/s11527-008-9351-410.1617/s11527-008-9351-4 ↗
36. 10.1061/(ASCE)CC.1943-5614.000108710.1061/(ASCE)CC.1943-5614.0001087 ↗
37. 10.1061/JSDEAG.000541610.1061/JSDEAG.0005416 ↗
38. 10.1061/(ASCE)CC.1943-5614.000049610.1061/(ASCE)CC.1943-5614.0000496 ↗
39. 10.1016/j.conbuildmat.2020.12143610.1016/j.conbuildmat.2020.121436 ↗
40. Wang, J., L. Yang, and J. Yang. 2020. “Bond behavior of epoxy-coated reinforcing bars with seawater sea-sand concrete.” ACI Struct. J. 117 (4): 193–208.
41. 10.1016/j.engstruct.2007.04.01610.1016/j.engstruct.2007.04.016 ↗
42. Wang, X. H., and L. Zheng. 2020. “Durability and ultimate performance of concrete beams with epoxy-coated reinforcing bars.” Proc. Inst. Civ. Eng. Struct. Build. 1–16. https://doi.org/10.1680/jstbu.19.00156.
43. 10.1016/j.compstruct.2020.11308210.1016/j.compstruct.2020.113082 ↗
44. 10.1016/j.compstruct.2007.04.00210.1016/j.compstruct.2007.04.002 ↗
45. 10.1061/(ASCE)CC.1943-5614.000024510.1061/(ASCE)CC.1943-5614.0000245 ↗
46. 10.1016/j.conbuildmat.2011.06.03710.1016/j.conbuildmat.2011.06.037 ↗
47. Wu, Y. F. 2008. “Ductility demand of compression yielding fiber-reinforced polymer-reinforced concrete beams.” ACI Struct. J. 105 (1): 104–110.
48. 10.1002/suco.20190007110.1002/suco.201900071 ↗
49. Xu, Y., Y. Wei, X. Cheng, and M. Duan. 2019. “Axial compressive behavior of CFRP-stirrup confined rounded rectangular concrete columns.” [In Chinese.] Fiber Reinf. Plast./Compos. (6): 5–11.
50. 10.1016/j.engstruct.2020.11111910.1016/j.engstruct.2020.111119 ↗
51. 10.1016/j.compstruct.2020.11237310.1016/j.compstruct.2020.112373 ↗
52. 10.1016/j.compstruct.2020.11236810.1016/j.compstruct.2020.112368 ↗
53. 10.1177/136943322093346110.1177/1369433220933461 ↗
54. Yuan, J., and Z. Ou. 2021. “Research progress and engineering applications of stainless steel-reinforced concrete structures.” Adv. Civ. Eng. 2021: 9228493. https://doi.org/10.1155/2021/9228493.10.1155/2021/9228493 ↗
55. 10.1016/j.conbuildmat.2019.11738310.1016/j.conbuildmat.2019.117383 ↗
56. 10.1016/j.engstruct.2018.07.08610.1016/j.engstruct.2018.07.086 ↗
57. 10.1016/j.compstruct.2020.11242110.1016/j.compstruct.2020.112421 ↗
58. 10.1016/j.conbuildmat.2020.11806210.1016/j.conbuildmat.2020.118062 ↗
59. 10.1016/j.conbuildmat.2017.08.04910.1016/j.conbuildmat.2017.08.049 ↗