Web Buckling in Pultruded Fiber-Reinforced Polymer Deep Beams Subjected to Concentrated Loads
Source abstract
Abstract
Five 609.5-mm deep fiber-reinforced polymer (FRP) beams with a span-to-depth ratio of 4∶1 were tested in three-point bending with the beam ends constrained to prevent global failure. A concentrated load was applied at midspan either directly to the top flange or through a 101.6 mm wide by 12.7-mm thick FRP bearing plate resting on the top flange. VIC-3D Digital Image Correlation Measurement Software from Correlated Solutions captured out-of-plane displacement of the webs, and Southwell plots were generated to determine buckling loads. Each specimen experienced a stability failure of the web before undergoing material failure in the upper web-flange junction. On average, web buckling occurred at 90% of the ultimate load. The introduction of a bearing plate did not significantly affect the buckling load or ultimate capacity of the specimens. One specimen was tested into the postbuckling range, unloaded, and reloaded to material failure and experienced no loss of strength or stiffness. Another specimen with significant damage to the unloaded web-flange junction was tested and compared with a virgin sample. The damaged sample experienced no significant loss of strength or stiffness. Comparisons of experimental data with three theoretical equations for web-buckling capacity of FRP beams are provided.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Assistant Professor, Dept. of Civil and Mechanical Engineering, U.S. Military Academy, 752 Thayer Rd., 331 Mahan Hall, West Point, NY 10996 (corresponding author).
Professor, Dept. of Civil Engineering, City College of New York, 160 Convent Ave., New York, NY 10031.
References (23)
Show source-provided references
1. ASCE · 1984 · 728
2. ASCE. (2011). Pre-standard for load and resistance factor design (LRFD) of pultruded fiber reinforced polymer (FRP) structures 〈http://www.acmanet.org/resources/lrfd.cfm〉.
3. ASTM D7290
4. 10.1002/978047012142910.1002/9780470121429 ↗
5. 10.1115/1.290427810.1115/1.2904278 ↗
6. Basler K. (1961). “New provisions for plate girder design.” Proc. AISC National Engineering Conf. AISC Minneapolis 65–74.
7. Borowicz D. (2010). “An investigation into the behavior of fiber-reinforced polymer (FRP) beams subjected to concentrated loads in the plane of the web.” Doctoral dissertation Univ. of Wisconsin-Madison Madison WI.
8. 10.1061/(ASCE)CC.1943-5614.000008210.1061/(ASCE)CC.1943-5614.0000082 ↗
9. D’Alessandro R. (2009). “Characteristic values of mechanical properties of wide-flange pultruded FRF beams.” Master’s thesis Univ. of Wisconsin-Madison Madison WI.
10. Web design under compressive edge loads10.62913/engj.v20i4.401 ↗
11. Galambos T. V. · 1998
12. Gere J. · 1990
13. 10.1017/CBO978051154714010.1017/CBO9780511547140 ↗
14. Nadipelli M. (1994). “Experimental investigation of local buckling and failure of pultruded fiber reinforced plastic beams.” Master’s thesis Catholic Univ. of America Washington DC.
15. 10.1098/rspa.1932.005510.1098/rspa.1932.0055 ↗
16. Strongwell. (2002). 2002 design guide Bristol VA 〈http://www.strongwell.com/〉 (Feb. 01 2008).
17. Tarján G. Sapkás A. and Kollár L. P. (2009). “Local web buckling of composite (FRP) beams.” Proc. 17th Int. Conf. Compos. Mater. Edinburgh Scotland.10.1177/0731684409105083 ↗
18. 10.1177/073168440910508310.1177/0731684409105083 ↗
19. 10.1061/(ASCE)ST.1943-541X.000012610.1061/(ASCE)ST.1943-541X.0000126 ↗
20. 10.1007/BF0232510010.1007/BF02325100 ↗
21. 10.1016/j.jcsr.2007.10.00710.1016/j.jcsr.2007.10.007 ↗
22. 10.4028/www.scientific.net/KEM.261-26310.4028/www.scientific.net/KEM.261-263 ↗
23. 10.1177/07316844950140040510.1177/073168449501400405 ↗